- Home
- EPCRA Tier II
- Vermont
Vermont Tier II reporting: how and where to file
Vermont requires the current year's Tier2 Submit software. The last published filing window, for the 2025 reports, ran from January 1 to March 1, 2026.
From Vermont Emergency Management, read on the state's own page · September 26 and October 20, 2026
What Vermont asks for
Each point is followed by the words of the state's own page.
How to file
Vermont requires the current year's Tier2 Submit software. The last published filing window, for the 2025 reports, ran from January 1 to March 1, 2026.
“Vermont is requiring that all facilities use the Tier2 Submit 2025 software to submit the Tier2 report for calendar year 2025 between January 1 and March 1, 2026.” source
Who gets the report
Upload the .t2s file to the Tier II Submit Portal for the SERC, email it to the Statewide LEPC (electronic file only), and give the local fire department a hard copy or what the local jurisdiction requires.
“Hard copy, or as required by local jurisdiction.” source
“Emailed to DPS.StatewideLEPC@vermont.gov.” source
“Complete registration, follow the prompt, and upload your .t2s file.” source
State-specific rule
Send a Safety Data Sheet with the Tier II file for each reported hazardous material, if required. After the report is received an invoice is generated and emailed; payment can be mailed or made by eCheck in the portal.
“a Safety Data Sheet (SDS) for each reported hazardous material, if required” source
“Once the report has been received, an invoice for the fees owed will be generated and email notification will be sent.” source
The federal rule underneath
EPCRA section 312 applies to a facility that the OSHA HazCom Standard requires to keep an SDS for a hazardous chemical present at any one time at or above 10,000 lb, or at or above 500 lb or its threshold planning quantity, whichever is lower, for an extremely hazardous substance (40 CFR 370.10(a)). The 10,000 lb figure is the general case: at a retail gas station the thresholds are 75,000 gallons of gasoline and 100,000 gallons of diesel fuel (all grades combined), and they apply only to fuel in tanks entirely underground that met every applicable underground storage tank requirement at all times during the preceding calendar year (40 CFR 370.10(a)(2)(ii) and (iii)); otherwise the general threshold applies. The report covers the previous calendar year and is due March 1 (40 CFR 370.45). Below every threshold, a request still has to be answered: when your LEPC, SERC or fire department asks for Tier II information, the threshold is zero and the information is due within 30 days (40 CFR 370.10(b), 370.45(b)). Where Vermont's rules above are stricter, they apply on top.
The full federal picture, Tier I versus Tier II, counting and penalties, is on the EPCRA Tier II hub. The list that feeds it is the chemical inventory.
HazComFast keeps each jobsite's chemical quantities next to its safety data sheets and exports the Tier II data as an Excel workbook, a CSV file and a PDF summary.
Vermont Tier II FAQ
How do I file Tier II in Vermont?
Vermont requires the current year's Tier2 Submit software. The last published filing window, for the 2025 reports, ran from January 1 to March 1, 2026.
Who gets the Tier II report in Vermont?
Upload the .t2s file to the Tier II Submit Portal for the SERC, email it to the Statewide LEPC (electronic file only), and give the local fire department a hard copy or what the local jurisdiction requires. The federal rule is that the report reaches the LEPC, the SERC and the fire department with jurisdiction (42 U.S.C. 11022(a)(1)); in a state that takes the report in one system and passes it on, that system can meet the rule, and the state's own steps above say which applies.
More on Vermont
Tier II in other states
These 51 pages (the 50 states and DC) quote each state's own page or EPA's page of state procedures. For a territory, EPA's State Tier II Reporting Requirements and Procedures names the agency and the filing method.
- Alabama
- Colorado
- Connecticut
- Delaware
- Florida
- Georgia
- Hawaii
- Illinois
- Indiana
- Iowa
- Kansas
- Louisiana
- Massachusetts
- Mississippi
- Michigan
- Missouri
- Montana
- Nevada
- New Hampshire
- New Jersey
- New Mexico
- North Carolina
- North Dakota
- Oklahoma
- Oregon
- Pennsylvania
- South Dakota
- Texas
- Virginia
- Washington
- Wisconsin
- Wyoming
- Maine
- Alaska
- Arizona
- Arkansas
- California
- District of Columbia
- Idaho
- Kentucky
- Maryland
- Minnesota
- Nebraska
- New York
- Ohio
- Rhode Island
- South Carolina
- Tennessee
- Utah
- West Virginia
Sources
- vem.vermont.gov/programs/epcra
- www.epa.gov/epcra/state-tier-ii-reporting-requirements-and-procedures
- ecfr.gov/current/title-40/part-370
Vermont's requirements from the state's own page, accessed September 26 and October 20, 2026; 40 CFR part 370 from the eCFR, accessed September 26, 2026. States change portals and fees; confirm with Vermont Emergency Management before you file. General guidance, not legal advice.
Keep the chemical list behind your Tier II report current
Tier II is an EPCRA filing to your state and local agencies, not an OSHA citation. The same chemical inventory feeds your SDS binder and the report, so keep it in one place.
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.