Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

EPCRA §312MA

Massachusetts Tier II reporting: how and where to file

The SERC receives Tier II reports through the Hazconnect system. Due by March 1 of each year; enter the annual report after the first week of January, when the system is updated for the current reporting year. The Massachusetts SERC charges no filing fee, but a local LEPC might.

From Massachusetts State Emergency Response Commission (SERC), read on the state's own page · September 26 and October 20, 2026

What Massachusetts asks for

Each point is followed by the words of the state's own page.

How to file

The SERC receives Tier II reports through the Hazconnect system.

“The Massachusetts SERC receives Tier II reports through submissions to the Hazconnect System.” source

How to file

Hazconnect can export the report as a copy, a PDF or a .t2s file, whichever format the fire department or the LEPC asks for.

“you may export the report to whichever format they need Copy; PDF; or a Tier II Submit (t2s) compatible file.” source

Deadline

Due by March 1 of each year; enter the annual report after the first week of January, when the system is updated for the current reporting year.

“The required annual Tier II reports must be entered after the first week of January, so the system is updated for the current reporting year and are due by March 1 of each year.” source

Fees

The Massachusetts SERC charges no filing fee, but a local LEPC might.

“Q: Does the Massachusetts SERC charge a filing fee to submit Tier II reports? A: No. However, your local LEPC might have fees.” source

Who gets the report

Each year the report goes to the facility's Emergency Planning Committee, its local fire department and the SERC. Hazconnect covers the SERC only; contact the fire department and the Emergency Planning Committee about their own requirements.

“Facilities covered by the EPCRA reporting requirements must submit Tier II reports to their: Emergency Planning Committee (EPC), their Local Fire Department, and the SERC annually.” source
“Filers must contact their Local Fire Department and EPC regarding their respective reporting requirements.” source

The federal rule underneath

EPCRA section 312 applies to a facility that the OSHA HazCom Standard requires to keep an SDS for a hazardous chemical present at any one time at or above 10,000 lb, or at or above 500 lb or its threshold planning quantity, whichever is lower, for an extremely hazardous substance (40 CFR 370.10(a)). The 10,000 lb figure is the general case: at a retail gas station the thresholds are 75,000 gallons of gasoline and 100,000 gallons of diesel fuel (all grades combined), and they apply only to fuel in tanks entirely underground that met every applicable underground storage tank requirement at all times during the preceding calendar year (40 CFR 370.10(a)(2)(ii) and (iii)); otherwise the general threshold applies. The report covers the previous calendar year and is due March 1 (40 CFR 370.45). Below every threshold, a request still has to be answered: when your LEPC, SERC or fire department asks for Tier II information, the threshold is zero and the information is due within 30 days (40 CFR 370.10(b), 370.45(b)). Where Massachusetts's rules above are stricter, they apply on top.

The full federal picture, Tier I versus Tier II, counting and penalties, is on the EPCRA Tier II hub. The list that feeds it is the chemical inventory.

HazComFast keeps each jobsite's chemical quantities next to its safety data sheets and exports the Tier II data as an Excel workbook, a CSV file and a PDF summary.

Massachusetts Tier II FAQ

How do I file Tier II in Massachusetts?

The SERC receives Tier II reports through the Hazconnect system. Hazconnect can export the report as a copy, a PDF or a .t2s file, whichever format the fire department or the LEPC asks for.

When is Tier II due in Massachusetts?

Due by March 1 of each year; enter the annual report after the first week of January, when the system is updated for the current reporting year.

Does Massachusetts charge a Tier II fee?

The Massachusetts SERC charges no filing fee, but a local LEPC might.

Who gets the Tier II report in Massachusetts?

Each year the report goes to the facility's Emergency Planning Committee, its local fire department and the SERC. Hazconnect covers the SERC only; contact the fire department and the Emergency Planning Committee about their own requirements. The federal rule is that the report reaches the LEPC, the SERC and the fire department with jurisdiction (42 U.S.C. 11022(a)(1)); in a state that takes the report in one system and passes it on, that system can meet the rule, and the state's own steps above say which applies.

More on Massachusetts

Tier II in other states

These 51 pages (the 50 states and DC) quote each state's own page or EPA's page of state procedures. For a territory, EPA's State Tier II Reporting Requirements and Procedures names the agency and the filing method.

Sources

Massachusetts's requirements from the state's own page, accessed September 26 and October 20, 2026; 40 CFR part 370 from the eCFR, accessed September 26, 2026. States change portals and fees; confirm with Massachusetts State Emergency Response Commission (SERC) before you file. General guidance, not legal advice.

Keep the chemical list behind your Tier II report current

Tier II is an EPCRA filing to your state and local agencies, not an OSHA citation. The same chemical inventory feeds your SDS binder and the report, so keep it in one place.

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.

Your account keeps working as usual. Cancel anytime.