- Home
- EPCRA Tier II
- Maine
Maine Tier II reporting: how and where to file
Filing is electronic only, with EPA's free Tier2 Submit software. Maine charges registration and inventory fees, payable by credit card.
From Maine Emergency Management Agency (MEMA), State Emergency Response Commission, read on the state's own page · September 26 and October 20, 2026
What Maine asks for
Each point is followed by the words of the state's own page.
How to file
Filing is electronic only, with EPA's free Tier2 Submit software.
“Filing must be done electronically, using US EPA's Tier II Submit software, available free from the EPA.” source
Fees
Maine charges registration and inventory fees, payable by credit card.
“In Maine, there are registration and inventory fees associated with the reports.” source
“Pay for your EPCRA Tier 2 Fees with a credit card.” source
Who gets the report
The annual report goes to the local fire department, the Local Emergency Planning Committee (LEPC) and the State Emergency Response Commission (SERC).
“These facilities must report those inventories each year to: The local fire department, Local Emergency Planning Committee and The State Emergency Response Commission (SERC) annually.” source
State-specific rule
A facility whose inventory is over the threshold planning quantity of an extremely hazardous substance must also write an emergency plan, give it to the LEPC and the fire department, and review and exercise it every year.
“Facilities which maintain inventories over the TPQ of an EHS must also develop an emergency plan, provide it to the local LEPC and fire department, and annually review and exercise the plan.” source
The federal rule underneath
EPCRA section 312 applies to a facility that the OSHA HazCom Standard requires to keep an SDS for a hazardous chemical present at any one time at or above 10,000 lb, or at or above 500 lb or its threshold planning quantity, whichever is lower, for an extremely hazardous substance (40 CFR 370.10(a)). The 10,000 lb figure is the general case: at a retail gas station the thresholds are 75,000 gallons of gasoline and 100,000 gallons of diesel fuel (all grades combined), and they apply only to fuel in tanks entirely underground that met every applicable underground storage tank requirement at all times during the preceding calendar year (40 CFR 370.10(a)(2)(ii) and (iii)); otherwise the general threshold applies. The report covers the previous calendar year and is due March 1 (40 CFR 370.45). Below every threshold, a request still has to be answered: when your LEPC, SERC or fire department asks for Tier II information, the threshold is zero and the information is due within 30 days (40 CFR 370.10(b), 370.45(b)). Where Maine's rules above are stricter, they apply on top.
The full federal picture, Tier I versus Tier II, counting and penalties, is on the EPCRA Tier II hub. The list that feeds it is the chemical inventory.
HazComFast keeps each jobsite's chemical quantities next to its safety data sheets and exports the Tier II data as an Excel workbook, a CSV file and a PDF summary.
Maine Tier II FAQ
How do I file Tier II in Maine?
Filing is electronic only, with EPA's free Tier2 Submit software.
Does Maine charge a Tier II fee?
Maine charges registration and inventory fees, payable by credit card.
Who gets the Tier II report in Maine?
The annual report goes to the local fire department, the Local Emergency Planning Committee (LEPC) and the State Emergency Response Commission (SERC). The federal rule is that the report reaches the LEPC, the SERC and the fire department with jurisdiction (42 U.S.C. 11022(a)(1)); in a state that takes the report in one system and passes it on, that system can meet the rule, and the state's own steps above say which applies.
More on Maine
Tier II in other states
These 51 pages (the 50 states and DC) quote each state's own page or EPA's page of state procedures. For a territory, EPA's State Tier II Reporting Requirements and Procedures names the agency and the filing method.
- Alabama
- Colorado
- Connecticut
- Delaware
- Florida
- Georgia
- Hawaii
- Illinois
- Indiana
- Iowa
- Kansas
- Louisiana
- Massachusetts
- Mississippi
- Michigan
- Missouri
- Montana
- Nevada
- New Hampshire
- New Jersey
- New Mexico
- North Carolina
- North Dakota
- Oklahoma
- Oregon
- Pennsylvania
- South Dakota
- Texas
- Vermont
- Virginia
- Washington
- Wisconsin
- Wyoming
- Alaska
- Arizona
- Arkansas
- California
- District of Columbia
- Idaho
- Kentucky
- Maryland
- Minnesota
- Nebraska
- New York
- Ohio
- Rhode Island
- South Carolina
- Tennessee
- Utah
- West Virginia
Sources
- www.maine.gov/mema/hazards/serc/facility-resources
- www.maine.gov/mema/hazards/serc
- ecfr.gov/current/title-40/part-370
Maine's requirements from the state's own page, accessed September 26 and October 20, 2026; 40 CFR part 370 from the eCFR, accessed September 26, 2026. States change portals and fees; confirm with Maine Emergency Management Agency (MEMA), State Emergency Response Commission before you file. General guidance, not legal advice.
Keep the chemical list behind your Tier II report current
Tier II is an EPCRA filing to your state and local agencies, not an OSHA citation. The same chemical inventory feeds your SDS binder and the report, so keep it in one place.
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.