- Home
- EPCRA Tier II
- South Dakota
South Dakota Tier II reporting: how and where to file
South Dakota files through its own SD Online Tier II reporting system.
From South Dakota Department of Agriculture and Natural Resources (DANR), read on the state's own page · September 26 and October 20, 2026
What South Dakota asks for
Each point is followed by the words of the state's own page.
How to file
South Dakota files through its own SD Online Tier II reporting system.
“SD Online Tier II reporting login” source
How to file
Signing the online report submits it to the state. Then print the signed report and send copies to the Local Emergency Planning Committee, the Emergency Manager, the Fire Department and, where applicable, the local tribal government; the tool does not send them.
“Print copies of your signed report and submit copies to all the other appropriate” source
“Your online report was submitted to the state when it was signed.” source
The federal rule underneath
EPCRA section 312 applies to a facility that the OSHA HazCom Standard requires to keep an SDS for a hazardous chemical present at any one time at or above 10,000 lb, or at or above 500 lb or its threshold planning quantity, whichever is lower, for an extremely hazardous substance (40 CFR 370.10(a)). The 10,000 lb figure is the general case: at a retail gas station the thresholds are 75,000 gallons of gasoline and 100,000 gallons of diesel fuel (all grades combined), and they apply only to fuel in tanks entirely underground that met every applicable underground storage tank requirement at all times during the preceding calendar year (40 CFR 370.10(a)(2)(ii) and (iii)); otherwise the general threshold applies. The report covers the previous calendar year and is due March 1 (40 CFR 370.45). Below every threshold, a request still has to be answered: when your LEPC, SERC or fire department asks for Tier II information, the threshold is zero and the information is due within 30 days (40 CFR 370.10(b), 370.45(b)). Where South Dakota's rules above are stricter, they apply on top.
The full federal picture, Tier I versus Tier II, counting and penalties, is on the EPCRA Tier II hub. The list that feeds it is the chemical inventory.
HazComFast keeps each jobsite's chemical quantities next to its safety data sheets and exports the Tier II data as an Excel workbook, a CSV file and a PDF summary.
South Dakota Tier II FAQ
How do I file Tier II in South Dakota?
South Dakota files through its own SD Online Tier II reporting system. Signing the online report submits it to the state. Then print the signed report and send copies to the Local Emergency Planning Committee, the Emergency Manager, the Fire Department and, where applicable, the local tribal government; the tool does not send them.
More on South Dakota
Tier II in other states
These 51 pages (the 50 states and DC) quote each state's own page or EPA's page of state procedures. For a territory, EPA's State Tier II Reporting Requirements and Procedures names the agency and the filing method.
- Alabama
- Colorado
- Connecticut
- Delaware
- Florida
- Georgia
- Hawaii
- Illinois
- Indiana
- Iowa
- Kansas
- Louisiana
- Massachusetts
- Mississippi
- Michigan
- Missouri
- Montana
- Nevada
- New Hampshire
- New Jersey
- New Mexico
- North Carolina
- North Dakota
- Oklahoma
- Oregon
- Pennsylvania
- Texas
- Vermont
- Virginia
- Washington
- Wisconsin
- Wyoming
- Maine
- Alaska
- Arizona
- Arkansas
- California
- District of Columbia
- Idaho
- Kentucky
- Maryland
- Minnesota
- Nebraska
- New York
- Ohio
- Rhode Island
- South Carolina
- Tennessee
- Utah
- West Virginia
Sources
- danr.sd.gov/Agriculture/Inspection/SARATitle3/default.aspx
- danr.sd.gov/Agriculture/Inspection/Tier2/docs/NEW%20Paper%20Fee%20Reporting%20Guide.pdf
- ecfr.gov/current/title-40/part-370
South Dakota's requirements from the state's own page, accessed September 26 and October 20, 2026; 40 CFR part 370 from the eCFR, accessed September 26, 2026. States change portals and fees; confirm with South Dakota Department of Agriculture and Natural Resources (DANR) before you file. General guidance, not legal advice.
Keep the chemical list behind your Tier II report current
Tier II is an EPCRA filing to your state and local agencies, not an OSHA citation. The same chemical inventory feeds your SDS binder and the report, so keep it in one place.
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.