Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

EPCRA §312CT

Connecticut Tier II reporting: how and where to file

File in the Hazconnect Tier II Manager system, due March 1. Tier2 Submit by email is accepted only when unique circumstances prevent using Hazconnect.

From Connecticut State Emergency Response Commission, with the Department of Energy and Environmental Protection (CT DEEP), read on the state's own page · September 26, 2026

What Connecticut asks for

Each point is followed by the words of the state's own page.

How to file

File in the Hazconnect Tier II Manager system, due March 1. Tier2 Submit by email is accepted only when unique circumstances prevent using Hazconnect.

“The Connecticut State Emergency Response Commission and the Department of Energy and Environmental Protection uses the Hazconnect Tier II Manager system to manage EPCRA Tier II chemical inventory reports due March 1 of each year.” source

Who gets the report

You still send the report directly to your LEPC and local fire department, with a site plan and the SDSs attached.

“Facilities are still required to directly submit reports to their Local Emergency Planning Committee and local Fire Department, with Site Plan and SDS attachments.” source
“Connecticut will accept submittal of reports via EPA's Tier2 Submit Software with electronic file submissions sent to DEEP.CTEPCRA@ct.gov only f needed due to unique circumstances preventing use of the Hazconnect platform.” source

The federal rule underneath

EPCRA section 312 applies to a facility that the OSHA HazCom Standard requires to keep an SDS for a hazardous chemical present at any one time at or above 10,000 lb, or at or above 500 lb or its threshold planning quantity, whichever is lower, for an extremely hazardous substance (40 CFR 370.10(a)). The 10,000 lb figure is the general case: at a retail gas station the thresholds are 75,000 gallons of gasoline and 100,000 gallons of diesel fuel (all grades combined), and they apply only to fuel in tanks entirely underground that met every applicable underground storage tank requirement at all times during the preceding calendar year (40 CFR 370.10(a)(2)(ii) and (iii)); otherwise the general threshold applies. The report covers the previous calendar year and is due March 1 (40 CFR 370.45). Below every threshold, a request still has to be answered: when your LEPC, SERC or fire department asks for Tier II information, the threshold is zero and the information is due within 30 days (40 CFR 370.10(b), 370.45(b)). Where Connecticut's rules above are stricter, they apply on top.

The full federal picture, Tier I versus Tier II, counting and penalties, is on the EPCRA Tier II hub. The list that feeds it is the chemical inventory.

HazComFast keeps each jobsite's chemical quantities next to its safety data sheets and exports the Tier II data as an Excel workbook, a CSV file and a PDF summary.

Connecticut Tier II FAQ

How do I file Tier II in Connecticut?

File in the Hazconnect Tier II Manager system, due March 1. Tier2 Submit by email is accepted only when unique circumstances prevent using Hazconnect.

Who gets the Tier II report in Connecticut?

You still send the report directly to your LEPC and local fire department, with a site plan and the SDSs attached. The federal rule is that the report reaches the LEPC, the SERC and the fire department with jurisdiction (42 U.S.C. 11022(a)(1)); in a state that takes the report in one system and passes it on, that system can meet the rule, and the state's own steps above say which applies.

More on Connecticut

Tier II in other states

These 51 pages (the 50 states and DC) quote each state's own page or EPA's page of state procedures. For a territory, EPA's State Tier II Reporting Requirements and Procedures names the agency and the filing method.

Sources

Connecticut's requirements from the state's own page, accessed September 26, 2026; 40 CFR part 370 from the eCFR, accessed September 26, 2026. States change portals and fees; confirm with Connecticut State Emergency Response Commission, with the Department of Energy and Environmental Protection (CT DEEP) before you file. General guidance, not legal advice.

Keep the chemical list behind your Tier II report current

Tier II is an EPCRA filing to your state and local agencies, not an OSHA citation. The same chemical inventory feeds your SDS binder and the report, so keep it in one place.