Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

EPCRA §312FL

Florida Tier II reporting: how and where to file

All filing and fee payment go through the E-Plan online database, by credit card or ACH transfer. Due March 1 for the previous year. Florida charges Tier II fees, which fund emergency planning; the amounts are in the state's How to Comply manual.

From Florida Division of Emergency Management (SERC), read on the state's own page · September 26, 2026

What Florida asks for

Each point is followed by the words of the state's own page.

How to file

All filing and fee payment go through the E-Plan online database, by credit card or ACH transfer.

“Florida now utilizes the E-Plan Online Database for all filing and fee collection.” source
“Filers now have the option of paying fees with a credit card or electronic funds transfer (ACH) from their bank account.” source

How to file

The report can be created and submitted directly in E-Plan, or built with EPA's Tier2Submit and uploaded.

“Upload Tier II files generated with EPA's Tier2Submit software” source
“Use E-Plan to create and submit their Tier II reports directly, or” source

Deadline

Due March 1 for the previous year.

“The deadline for filing a Tier II report for the previous year is March 1st.” source

Fees

Florida charges Tier II fees, which fund emergency planning; the amounts are in the state's How to Comply manual.

“The fees assessed for Tier II facilities by State of Florida provide funding for new and ongoing emergency planning initiatives.” source
“Please see How to Comply Manual and Consolidated List of Chemicals for more information on fees.” source

Fees

Annual fees by category in the How to Comply manual: Category A, regulated industries covered by chapters 368, 527 or section 376.303 of the Florida Statutes, $2.50 per employee with a $25 minimum and a $500 maximum; Category B, agricultural facilities under the routine agricultural use exemption, $10 per employee with a $25 minimum and a $1,000 maximum, and only if no extremely hazardous substance at or above its threshold planning quantity is present; Category C, all other facilities, $10 per employee with a $25 minimum and a $2,000 maximum.

“$2.50 PER EMPLOYEE” source
“$25 MINIMUM” source
“$500 MAXIMUM” source
“$10 PER EMPLOYEE” source
“$1,000 MAXIMUM” source
“$2,000 MAXIMUM” source
“COMPANIES ARE ELIGIBLE FOR THE REDUCED FEE ONLY IF THEY DO NOT HAVE PRESENT EHSS THAT MEET OR EXCEED THE TPQ.” source
“BY CHAPTERS 368, 527, OR” source
“376.303, FLORIDA STATUTES” source
“Facilities must report any chemicals that were present at or above the applicable Threshold Planning Quantities (TPQs) at any point during the previous calendar year.” source

State thresholds

Florida's general page counts substances stored, used or manufactured on site for more than 24 hours at any time in the previous calendar year, but its How to Comply manual says chemicals present at or above the applicable threshold planning quantities at any point during the previous calendar year are reported, and the federal rule has no 24-hour minimum. Do not treat a stock held for less than 24 hours as exempt without asking FDEM.

“regulated industries must file an annual Tier II report with the SERC, LEPC, and local fire department for hazardous and/or extremely hazardous substances stored, used, or manufactured on site for more than a 24 hour period at any time during the previous calendar year.” source

Federal law sets no minimum time: EPA reads "present at the facility" as present at any one time during the year, so a quantity above the federal threshold for less than 24 hours is still reportable under section 312. EPA

Who gets the report

Filing in E-Plan satisfies the SERC and LEPC notification requirements; contact the local fire department to confirm how it prefers to receive the report (E-Plan, email or mail).

“Important: Contact your local fire department to determine their preferred method of receiving notification (E-Plan, email, or mail).” source
“E-Plan satisfies the State Emergency Response Commission (SERC) and Local Emergency Planning Committee (LEPC) notification requirements.” source

The federal rule underneath

EPCRA section 312 applies to a facility that the OSHA HazCom Standard requires to keep an SDS for a hazardous chemical present at any one time at or above 10,000 lb, or at or above 500 lb or its threshold planning quantity, whichever is lower, for an extremely hazardous substance (40 CFR 370.10(a)). The 10,000 lb figure is the general case: at a retail gas station the thresholds are 75,000 gallons of gasoline and 100,000 gallons of diesel fuel (all grades combined), and they apply only to fuel in tanks entirely underground that met every applicable underground storage tank requirement at all times during the preceding calendar year (40 CFR 370.10(a)(2)(ii) and (iii)); otherwise the general threshold applies. The report covers the previous calendar year and is due March 1 (40 CFR 370.45). Below every threshold, a request still has to be answered: when your LEPC, SERC or fire department asks for Tier II information, the threshold is zero and the information is due within 30 days (40 CFR 370.10(b), 370.45(b)). Where Florida's rules above are stricter, they apply on top.

The full federal picture, Tier I versus Tier II, counting and penalties, is on the EPCRA Tier II hub. The list that feeds it is the chemical inventory.

HazComFast keeps each jobsite's chemical quantities next to its safety data sheets and exports the Tier II data as an Excel workbook, a CSV file and a PDF summary.

Florida Tier II FAQ

How do I file Tier II in Florida?

All filing and fee payment go through the E-Plan online database, by credit card or ACH transfer. The report can be created and submitted directly in E-Plan, or built with EPA's Tier2Submit and uploaded.

When is Tier II due in Florida?

Due March 1 for the previous year.

Does Florida charge a Tier II fee?

Florida charges Tier II fees, which fund emergency planning; the amounts are in the state's How to Comply manual. Annual fees by category in the How to Comply manual: Category A, regulated industries covered by chapters 368, 527 or section 376.303 of the Florida Statutes, $2.50 per employee with a $25 minimum and a $500 maximum; Category B, agricultural facilities under the routine agricultural use exemption, $10 per employee with a $25 minimum and a $1,000 maximum, and only if no extremely hazardous substance at or above its threshold planning quantity is present; Category C, all other facilities, $10 per employee with a $25 minimum and a $2,000 maximum.

Does Florida use the federal Tier II thresholds?

Florida's general page counts substances stored, used or manufactured on site for more than 24 hours at any time in the previous calendar year, but its How to Comply manual says chemicals present at or above the applicable threshold planning quantities at any point during the previous calendar year are reported, and the federal rule has no 24-hour minimum. Do not treat a stock held for less than 24 hours as exempt without asking FDEM. Federal law sets no minimum time: EPA reads "present at the facility" as present at any one time during the year, so a quantity above the federal threshold for less than 24 hours is still reportable under section 312.

Who gets the Tier II report in Florida?

Filing in E-Plan satisfies the SERC and LEPC notification requirements; contact the local fire department to confirm how it prefers to receive the report (E-Plan, email or mail). The federal rule is that the report reaches the LEPC, the SERC and the fire department with jurisdiction (42 U.S.C. 11022(a)(1)); in a state that takes the report in one system and passes it on, that system can meet the rule, and the state's own steps above say which applies.

More on Florida

Tier II in other states

These 51 pages (the 50 states and DC) quote each state's own page or EPA's page of state procedures. For a territory, EPA's State Tier II Reporting Requirements and Procedures names the agency and the filing method.

Sources

Florida's requirements from the state's own page, accessed September 26, 2026; 40 CFR part 370 from the eCFR, accessed September 26, 2026. States change portals and fees; confirm with Florida Division of Emergency Management (SERC) before you file. General guidance, not legal advice.