Construction term · Glossary

Electrical Safety (Construction)

Verified vs OSHA sources · 2026-10-05

The requirements of 29 CFR 1926 Subpart K, which protect construction workers from electrical hazards — shock, electrocution, arc flash, and fire. It covers ground-fault protection (GFCIs or an assured equipment grounding conductor program), proper wiring and grounding, safe distances from overhead power lines, lockout/tagout of energized equipment, and safe work practices. Electrocution is one of construction's “Fatal Four.”

29 CFR 1926 Subpart K29 CFR 1926.404(b)(1)(i)

Also known as: Subpart K, construction electrical safety

Electrical Safety (Construction) at a glance

  • Ground-fault protection required: GFCIs OR an assured equipment grounding conductor program.
  • Maintain safe clearances from overhead and underground power lines.
  • De-energize and lock out circuits before work; treat lines as live until verified.
  • Electrocution is one of OSHA's construction “Fatal Four” causes of death.

In plain English

The construction rules for not getting shocked, electrocuted, or burned by electricity — from using GFCI-protected power on site, to keeping cranes and ladders away from power lines, to locking out circuits before working on them.

What the rule says

“The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.”
29 CFR 1926.404(b)(1)(i)

In context

A concept governed primarily by OSHA's construction standards, 29 CFR Part 1926 — the rules that apply on jobsites rather than the general-industry 1910 set.

29 CFR 1926

Where this is written in OSHA's rules

Example

On a jobsite, all 120-volt temporary receptacles feed through GFCIs, cords are inspected for damage, the crew maintains at least the required clearance from an overhead line, and any panel work is done only after lockout/tagout — the core of Subpart K compliance.

Why it matters

Electrocution kills construction workers every year and is one of the “Fatal Four.” Subpart K's controls — GFCI protection, clearances from power lines, and de-energizing before work — are basic, high-impact, and heavily cited, because contact with electricity is almost always immediately fatal.

GFCI program vs. assured equipment grounding

Subpart K gives employers a choice for ground-fault protection: use GFCIs on receptacles, OR run an Assured Equipment Grounding Conductor Program (AEGCP) with documented inspections/tests of cords and equipment. GFCIs are simpler and far more common; an AEGCP is a paperwork-heavy alternative.

Key areas of construction electrical safety (Subpart K)

AreaRequirement
Ground-fault protectionGFCIs or an assured equipment grounding program
Overhead power linesMaintain safe clearance; treat as energized
Energized workDe-energize and lock out before working
Wiring & groundingProper design, grounding, and inspection of equipment/cords

Electrical Safety (Construction): frequently asked questions

What does OSHA require for electrical safety in construction?
29 CFR 1926 Subpart K requires ground-fault protection (GFCIs or an assured equipment grounding program), proper wiring and grounding, safe clearances from power lines, lockout/tagout of energized equipment, and safe work practices.
Do I need GFCIs on a construction site?
You need ground-fault protection: either GFCIs on 120-volt temporary receptacles, or a documented Assured Equipment Grounding Conductor Program. GFCIs are the simpler and more common choice.
Why is electrical safety so critical in construction?
Electrocution is one of OSHA's construction “Fatal Four.” Contact with energized circuits or power lines is frequently fatal, so Subpart K's controls are among the highest-impact life-safety requirements on a jobsite.

Related terms

Free tools for this

Governing OSHA standards

More Construction terms

29 CFR 1910

The part of Title 29 of the Code of Federal Regulations that contains OSHA's General Industry standards — the default rulebook for most American workplaces (manufacturing, warehousing, healthcare, etc.) that aren't covered by the construction, maritime, or agriculture standards. It includes core rules like Hazard Communication (1910.1200) and the permissible exposure limits (1910.1000). Several 1910 standards are cross-referenced into construction via Part 1926.

29 CFR 1926

The part of Title 29 of the Code of Federal Regulations that contains OSHA's Construction standards — the “Safety and Health Regulations for Construction.” It governs construction, alteration, and repair work, with construction-specific rules for fall protection (Subpart M), scaffolds (Subpart L), excavations (Subpart P), electrical (Subpart K), and more. Where a task isn't addressed in 1926, some general-industry (1910) standards apply by reference.

Anchor Point

The secure attachment point a personal fall arrest system (PFAS) ties off to — the “A” in the ABC of fall arrest. Under 29 CFR 1926.502(d)(15), a non-engineered anchorage must support at least 5,000 pounds per attached worker; alternatively, it can be an engineered anchorage designed and supervised by a qualified person with a safety factor of at least two.

Atmospheric Testing

Measuring the air in a confined space (or other hazardous atmosphere) with a calibrated direct-reading instrument before and during entry. OSHA requires testing in a set order — oxygen first, then flammable gases and vapors, then potential toxic contaminants — and defines the acceptable ranges: oxygen 19.5%–23.5%, flammables below 10% of the LEL, toxics below their exposure limits.

Benching

An excavation cave-in protective system that cuts the sides into a series of horizontal steps (benches), usually with vertical or near-vertical faces between levels. It's one of OSHA's accepted protective systems under Subpart P — but it is NOT permitted in Type C (the least stable) soil.

Competent Person (Excavation)

The competent person OSHA's excavation standard (Subpart P) requires on every trenching job — someone trained in soil classification and protective systems, who can identify cave-in and other hazards AND has authority to remove workers and correct problems. They must inspect the excavation daily before work starts, throughout the shift, and after any rain or event that could increase the hazard.

Confined Space

A space that is large enough for a worker to bodily enter, has limited or restricted means of entry or exit, and is not designed for continuous occupancy. If it also contains — or could contain — a serious hazard (a hazardous atmosphere, engulfment material, an entrapping configuration, or any other recognized serious hazard), it becomes a permit-required confined space (PRCS).

Controlling Employer

Under OSHA's Multi-Employer Citation Policy (CPL 02-00-124), the controlling employer is an employer with general supervisory authority over a worksite — including the power to correct safety and health violations itself or to require others to correct them. This is typically the general contractor or construction manager. A controlling employer can be cited for a hazard at the site even if none of its own employees are exposed, because it has a duty to exercise reasonable care to prevent and detect violations by the other employers on site.

Sources & verification

Reviewed by HazComFast against eCFR, OSHA.gov, NIOSH, and the Federal Register. Last reviewed 2026-10-05. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.

Put Electrical Safety (Construction) into practice

Don't just read the definition — apply it. Use the free HazCom Audit Checklist (2026) to put real numbers behind Electrical Safety (Construction) for your jobsite.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA does not give advance notice of inspections (29 CFR 1903.6). Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.

Your account keeps working as usual. Cancel anytime.