Construction term · Glossary
LOTO (Lockout/Tagout)
Verified vs OSHA sources · 2026-10-27
Procedures that isolate and de-energize machines and equipment during servicing and maintenance so they cannot unexpectedly start up or release stored energy. Lockout places a lock or other positive means on an energy isolating device to hold it in a safe position; tagout fastens a prominent warning device to it (1910.147(b)). The general industry standard, 29 CFR 1910.147, does not cover construction and agriculture employment (1910.147(a)(1)(ii)(A)). Construction has no single lockout/tagout standard, and the provision depends on the activity: 1926.417 for electrical circuits, 1926.702(j) for equipment used for concrete and masonry construction, and 1926.961 for de-energizing power transmission and distribution lines.
Also known as: lockout/tagout, control of hazardous energy
On this page
LOTO (Lockout/Tagout) at a glance
- Energy sources: 1910.147(b) defines an energy source as any source of electrical, mechanical, hydraulic, pneumatic, chemical, thermal, or other energy.
- General industry (1910.147): a program of energy control procedures, employee training and periodic inspections isolates the machine or equipment from the energy source and renders it inoperative before servicing or maintenance ((c)(1)). An energy isolating device that cannot be locked out is controlled by a tagout system; one that can be locked out is controlled by lockout unless the employer can demonstrate that tagout provides full employee protection, a level of safety equivalent to lockout ((c)(2), (c)(3)).
- The sequence of 1910.147(d): preparation for shutdown, machine or equipment shutdown, isolation, lockout or tagout device application, relief of stored energy, and verification of isolation.
- Scope: 1910.147 does not cover construction and agriculture employment ((a)(1)(ii)(A)). The provisions that apply in construction depend on the activity.
- Construction provisions: 1926.417 (electrical circuits) has controls to be deactivated tagged, and de-energized equipment or circuits rendered inoperative and tagged at all points where they can be energized; its text names tags and does not mention locks. 1926.702(j) (equipment such as compressors, mixers, screens or pumps used for concrete and masonry construction) allows maintenance or repair where inadvertent operation could cause injury only after all potentially hazardous energy sources have been locked out and tagged, with tags reading Do Not Start or similar language. 1926.961 (de-energizing transmission and distribution lines) has disconnecting means opened, rendered inoperable unless the design does not permit, or tagged.
- General Duty Clause: OSHA's Field Operations Manual says Section 5(a)(1) is not cited when a standard applies to the hazard, and that a general duty citation needs a recognized hazard causing or likely to cause death or serious physical harm, a feasible and useful method to correct it, and exposure of the cited employer's own employees.
- 1910.147 was OSHA's #4 most-cited standard in FY2025 (general industry).
In plain English
Keeping a machine from turning on or springing back to life while someone works on it. General industry follows 1910.147, which excludes construction. Construction has no single lockout/tagout standard, and the rule depends on the activity: electrical circuits, concrete and masonry equipment, power lines.
What the source says, in summary
This standard does not cover the following: (A) Construction and agriculture employment;
In context
A concept governed primarily by OSHA's construction standards, 29 CFR Part 1926: the rules that apply on jobsites rather than the general-industry 1910 set.
Where this is written in OSHA's rules
- 29 CFR 1910.147Read on eCFR / OSHA.gov
- 29 CFR 1910.147(a)(1)(ii)(A)Read on eCFR / OSHA.gov
Example
In this invented general industry illustration, before clearing a jam in a plant conveyor, an authorized employee shuts the conveyor down using the established procedure, operates the energy isolating device, locks the electrical disconnect with a lock that identifies the employee, relieves the stored pneumatic pressure, and verifies isolation before reaching in (1910.147(d)). On a construction site the provision would differ with the activity: servicing a concrete mixer falls under 1926.702(j), and de-energizing an electrical circuit under 1926.417.
Why it matters
1910.147 covers servicing and maintenance in which the unexpected energization or start-up of machines or equipment, or the release of stored energy, could cause injury to employees (1910.147(a)(1)(i)). It was OSHA's #4 most-cited standard in FY2025, in general industry. Stored or residual energy can remain after the power is off, and 1910.147(d)(5) has it relieved, disconnected, restrained and otherwise rendered safe after the devices are applied.
1910.147 (general industry) vs. construction
1910.147 does not apply to construction: it excludes construction and agriculture employment in 1910.147(a)(1)(ii)(A). The construction provisions depend on the activity (1926.417 for electrical circuits, 1926.702(j) for concrete and masonry equipment, 1926.961 for transmission and distribution lines). The choice between lockout and tagout and the six-step sequence come from 1910.147, so a construction program should not be described as “1910.147 compliant” without that caveat.
The lockout/tagout sequence of 1910.147(d) (general industry)
| Step | Action |
|---|---|
| 1 · Prepare | Before turning off the machine, the authorized employee knows the type and magnitude of the energy, its hazards and the means to control it ((d)(1)) |
| 2 · Shut down | Turn the machine or equipment off using the established procedure, with an orderly shutdown ((d)(2)) |
| 3 · Isolate | Locate and operate all energy isolating devices needed to isolate the equipment from the energy sources ((d)(3)) |
| 4 · Apply devices | Authorized employees affix lockout or tagout devices to each energy isolating device ((d)(4)) |
| 5 · Release stored energy | Relieve, disconnect, restrain or otherwise render safe all potentially hazardous stored or residual energy ((d)(5)) |
| 6 · Verify | The authorized employee verifies that isolation and de-energization have been accomplished before starting work ((d)(6)) |
LOTO (Lockout/Tagout): frequently asked questions
- What is LOTO (Lockout/Tagout)?
- Procedures that isolate and de-energize machines and equipment during servicing and maintenance so they cannot unexpectedly start up or release stored energy. Lockout places a lock or other positive means on an energy isolating device to hold it in a safe position; tagout fastens a prominent warning device to it (1910.147(b)). The general industry standard, 29 CFR 1910.147, does not cover construction and agriculture employment (1910.147(a)(1)(ii)(A)). Construction has no single lockout/tagout standard, and the provision depends on the activity: 1926.417 for electrical circuits, 1926.702(j) for equipment used for concrete and masonry construction, and 1926.961 for de-energizing power transmission and distribution lines.
- Does OSHA's 1910.147 lockout/tagout standard apply to construction?
- No. 1910.147 does not cover construction and agriculture employment (1910.147(a)(1)(ii)(A)). Construction provisions depend on the activity: 1926.417 for electrical circuits (tags, and circuits rendered inoperative), 1926.702(j) for maintenance or repair of equipment used for concrete and masonry construction (energy sources locked out and tagged), and 1926.961 for de-energizing transmission and distribution lines. OSHA's Field Operations Manual says the General Duty Clause is not cited when a standard applies to the hazard.
- What is the difference between lockout and tagout?
- Lockout places a lock or other positive means on an energy isolating device to hold it in a safe position; tagout fastens a prominent warning device to it, indicating that the device may not be operated until the tag is removed (1910.147(b)). Where 1910.147 applies, a device capable of being locked out is controlled by lockout, and a tagout-only program on such a device is allowed only if the employer demonstrates full employee protection equivalent to lockout (1910.147(c)(2)(ii), (c)(3)); tagout is the method for a device that is not capable of being locked out ((c)(2)(i)). In construction the method depends on the provision: 1926.417 names tags, and 1926.702(j) has energy sources locked out and tagged.
- Why is releasing stored energy so important?
- Turning off the power does not remove all energy. Under 1910.147(d)(5), after the lockout or tagout devices are applied, all potentially hazardous stored or residual energy is relieved, disconnected, restrained and otherwise rendered safe, and if stored energy could reaccumulate to a hazardous level, verification of isolation continues until the servicing or maintenance is completed or the possibility no longer exists.
Related terms
Free tools for this
Governing OSHA standards
More Construction terms
The part of Title 29 of the Code of Federal Regulations that contains OSHA's General Industry standards, the default rulebook for most American workplaces (manufacturing, warehousing, healthcare, etc.) that are not covered by the construction, maritime or agriculture standards. It includes core rules such as Hazard Communication (1910.1200) and the air contaminant limits (1910.1000). Construction work is covered by Part 1926, which 1910.12(a) adopts as standards for every employee engaged in construction work, and some requirements are the same in both parts: 1926.59 says the HazCom requirements for construction are identical to those of 1910.1200.
29 CFR 1926The part of Title 29 of the Code of Federal Regulations that contains OSHA's Construction standards, the “Safety and Health Regulations for Construction.” It applies to construction work, which 1910.12(b) defines as work for construction, alteration, and/or repair, including painting and decorating, with construction-specific rules for fall protection (Subpart M), scaffolds (Subpart L), excavations (Subpart P), electrical (Subpart K) and more. OSHA decides by the activity being performed and not only by the employer's general business. Some general-industry (1910) standards apply to construction because 1926 adopts them (HazCom through 1926.59) or because 1910 identifies them as applicable to construction; OSHA's Field Operations Manual says a hazard in construction work that no specific 1926 standard covers is not normally cited under 1910 unless that standard has been identified as applicable to construction.
Anchor PointThe secure attachment point a personal fall arrest system (PFAS) ties off to. Under 29 CFR 1926.502(d)(15), anchorages used for attachment of personal fall arrest equipment are independent of any anchorage being used to support or suspend platforms and capable of supporting 5,000 pounds or more pounds per employee attached, or are designed, installed and used as part of a complete personal fall arrest system that maintains a safety factor of two or more, under the supervision of a qualified person.
Atmospheric TestingMeasuring the air in a confined space with an instrument before and during entry, as part of the evaluation of a permit space (1926.1204(e)) or of the alternate procedures for a space whose only hazard is atmospheric and is controlled by forced air ventilation, which call for a calibrated direct-reading instrument (1926.1203(e)(2)(iii)). Testing is done in a set order: first oxygen, then combustible gases and vapors, then toxic gases and vapors (1926.1204(e)(3)). Whether an atmosphere is hazardous is defined in 1926.1202: flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit; oxygen below 19.5 percent or above 23.5 percent; a substance above its dose or permissible exposure limit; or any other atmospheric condition that is immediately dangerous to life or health. Readings within those ranges are one condition of an entry and are not enough on their own: the classification of the space, the permit, isolation, ventilation, an attendant and rescue also apply.
BenchingA method of protecting employees from cave-ins by excavating the sides of an excavation to form one or a series of horizontal levels or steps, usually with vertical or near-vertical surfaces between levels (1926.650(b)). Benching is one of the sloping and benching systems whose slopes and configurations are selected under 1926.652(b), by one of four options: a slope not steeper than 1½H:1V (Option 1), Appendices A and B (Option 2), other tabulated data (Option 3), or a design approved by a registered professional engineer (Option 4). Appendix B to Subpart P lists benched configurations for Type A and Type B soil in excavations 20 feet or less in depth, and it lists no benched configuration for Type C soil.
Competent Person (Excavation)In OSHA's excavation standard (Subpart P), a competent person is one who is capable of identifying existing and predictable hazards in the surroundings, or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them (1926.650(b)). The competent person inspects excavations, the adjacent areas and protective systems before the start of work, as needed throughout the shift (not a continuous watch), and after every rainstorm or other hazard increasing occurrence, when employee exposure can be reasonably anticipated (1926.651(k)(1)). Exposed employees are removed from the hazardous area when the competent person finds evidence of a possible cave-in or another hazardous condition, until the necessary precautions have been taken (1926.651(k)(2)). When Appendix A to Subpart P applies, a competent person also classifies each soil and rock deposit as stable rock, Type A, Type B or Type C, based on a visual and a manual analysis.
Confined SpaceA space that is large enough and so configured that an employee can bodily enter it, has limited or restricted means for entry and exit, and is not designed for continuous employee occupancy (1926.1202). It is a permit space (also called a PRCS) if it has one or more of these characteristics: it contains or has a potential to contain a hazardous atmosphere; it contains a material that has the potential for engulfing an entrant; it has an internal configuration such that an entrant could be trapped or asphyxiated by inwardly converging walls or by a floor that slopes downward and tapers to a smaller cross-section; or it contains any other recognized serious safety or health hazard. A competent person identifies the confined spaces and the permit spaces before work begins (1926.1203(a)). An employer that decides to have employees enter a permit space has a written permit space program (1926.1203(d)), or uses the alternate procedures of 1926.1203(e) when their conditions are met, and a permit space can be reclassified as a non-permit confined space only when a competent person determines that the requirements of 1926.1203(g) are met.
Controlling EmployerUnder OSHA's Multi-Employer Citation Policy (CPL 02-00-124), a controlling employer is an employer who has general supervisory authority over the worksite, including the power to correct safety and health violations itself or to have others correct them. Control can be established by contract or, in the absence of explicit contractual provisions, by the exercise of control in practice. In the policy's examples the controlling employer is a general contractor or a construction manager, and an architect or engineer is one only if the breadth of its involvement is sufficient. The policy works in two steps: first the employer's role (creating, exposing, correcting or controlling), then whether its actions were sufficient for that role. A controlling employer has a duty to exercise reasonable care to prevent and detect violations on the site, and it can be cited for another employer's violation of an OSHA standard even when none of its own employees are exposed, but only when it did not meet that duty.
Sources & verification
- 29 CFR 1910.147 (eCFR / OSHA.gov)
- 29 CFR 1910.147(a)(1)(ii)(A) (eCFR / OSHA.gov)
- OSHA: Control of Hazardous Energy (Lockout/Tagout)
- eCFR: 29 CFR 1910.147, The control of hazardous energy (lockout/tagout)
- eCFR: 29 CFR 1926.417, Lockout and tagging of circuits
- eCFR: 29 CFR 1926.702, Requirements for equipment and tools (paragraph (j), lockout/tagout procedures)
- eCFR: 29 CFR 1926.961, Deenergizing lines and equipment for employee protection
- OSHA: Field Operations Manual, Chapter 4, Violations (General Duty Clause)
Checked against the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
A related free tool
The free LOTO Procedure Generator covers a task related to LOTO (Lockout/Tagout). Read the rule above first, then use the tool for your own workplace.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.