Construction term · Glossary
Electrocution
Verified vs OSHA sources · 2026-10-27
Death caused by electrical energy, and one of the four hazard groups of OSHA's Construction Focus Four outreach training. OSHA's electrical page says its electrical standards are designed to protect employees exposed to dangers such as electric shock, electrocution, fires and explosions. Electrocution results from contact with energized circuits, overhead or buried power lines, or faulty equipment. An electrical injury that does not end in death is not called electrocution, and “electric shock” is also used for the contact itself, so the two terms overlap. Construction provisions for these routes of contact include 1926.416(a)(1) (employees who could contact an electric power circuit), 1926.404(b)(1)(ii) (ground-fault circuit interrupters on certain receptacles) and 1926.1053(b)(12) (ladders used where they could contact exposed energized electrical equipment).
Also known as: electrical fatality
On this page
Electrocution at a glance
- Electrocution is death from electrical energy. “Electric shock” is also used for the contact with electricity, and OSHA's electrical page names both among the dangers its standards address.
- Routes of contact: overhead or buried power lines, energized equipment and circuits, and faulty tools and cords.
- One of the four hazard groups in OSHA's Construction Focus Four training (falls, struck-by, caught-in or -between, and electrocution).
- An employee who could contact an electric power circuit in the course of work is protected against electric shock by deenergizing and grounding the circuit or by guarding it effectively by insulation or other means (1926.416(a)(1)). Before work starts, the employer finds out whether an energized circuit, exposed or concealed, is located where the work could bring a person, tool or machine into contact with it, posts warning signs and tells employees where the lines are (1926.416(a)(3)).
- On construction sites, 120-volt, single-phase, 15- and 20-ampere receptacle outlets that are not part of the permanent wiring and are in use by employees have approved ground-fault circuit interrupters, with an exception for certain small generators (1926.404(b)(1)(ii)). Worn or frayed electric cords or cables are not used (1926.416(e)(1)).
- Ladders have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment (1926.1053(b)(12)).
In plain English
Death caused by electricity, for example from touching a live wire, hitting a power line with a ladder or crane, or using a faulty tool. “Electric shock” is the word for the contact itself, and a shock that kills is an electrocution. It is one of the four groups in OSHA's Construction Focus Four training.
What the rule says
“No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.”
In context
A concept governed primarily by OSHA's construction standards, 29 CFR Part 1926 — the rules that apply on jobsites rather than the general-industry 1910 set.
Where this is written in OSHA's rules
- 29 CFR 1926 Subpart KRead on eCFR / OSHA.gov
- 29 CFR 1926.416(a)(1)Read on eCFR / OSHA.gov
Example
In this invented illustration, a worker raising an extension ladder contacts an overhead power line and is electrocuted. 1926.416(a)(3) has the employer find out before work starts whether an energized circuit is located where the work could bring a person, tool or machine into contact with it, and 1926.416(a)(1) protects an employee who could contact the circuit by deenergizing and grounding it or by guarding it effectively. A ladder used where it could contact exposed energized electrical equipment has nonconductive siderails (1926.1053(b)(12)).
Why it matters
OSHA says electricity has long been recognized as a serious workplace hazard. Contact with electricity can kill, and contact that does not kill can still injure. The construction provisions address the routes of contact: circuits the employee could contact (1926.416(a)), ground-fault circuit interrupters (1926.404(b)(1)(ii)) and damaged cords (1926.416(e)(1)).
Electrocution vs. electric shock
The terms overlap. Electrocution means death caused by electrical energy. “Electric shock” is the everyday word for the contact with electricity and its effects, and a shock that ends in death is an electrocution. OSHA's electrical page names both among the dangers its standards address.
Routes of electrical contact and construction provisions
| Route of contact | Provision |
|---|---|
| Circuits the employee could contact, including power lines | Deenergize and ground the circuit or guard it effectively; find out before work starts where energized circuits are located (1926.416(a)(1) and (a)(3)) |
| Receptacles in use by employees | Ground-fault circuit interrupters (1926.404(b)(1)(ii)) |
| Faulty cords and cables | Worn or frayed cords and cables are not used (1926.416(e)(1)) |
| Ladders near energized equipment | Nonconductive siderails (1926.1053(b)(12)) |
Electrocution: frequently asked questions
- What is Electrocution?
- Death caused by electrical energy, and one of the four hazard groups of OSHA's Construction Focus Four outreach training. OSHA's electrical page says its electrical standards are designed to protect employees exposed to dangers such as electric shock, electrocution, fires and explosions. Electrocution results from contact with energized circuits, overhead or buried power lines, or faulty equipment. An electrical injury that does not end in death is not called electrocution, and “electric shock” is also used for the contact itself, so the two terms overlap. Construction provisions for these routes of contact include 1926.416(a)(1) (employees who could contact an electric power circuit), 1926.404(b)(1)(ii) (ground-fault circuit interrupters on certain receptacles) and 1926.1053(b)(12) (ladders used where they could contact exposed energized electrical equipment).
- What is the difference between electrocution and electric shock?
- Electrocution means death caused by electrical energy. “Electric shock” is the everyday word for the contact with electricity and its effects, and a shock that ends in death is an electrocution. An electrical injury that does not end in death is not called electrocution.
- What are common routes of electrical contact in construction?
- Overhead or buried power lines, energized equipment and circuits, and faulty tools and cords. The construction provisions include protection from circuits the employee could contact (1926.416(a)(1)), finding out before work starts where energized circuits are (1926.416(a)(3)), ground-fault circuit interrupters on certain receptacles (1926.404(b)(1)(ii)) and nonconductive ladder siderails where a ladder could contact exposed energized equipment (1926.1053(b)(12)).
- Why is electrocution a Focus Four hazard?
- OSHA's Construction Focus Four outreach training has a module for each of four hazard groups: falls, struck-by, caught-in or -between, and electrocution. OSHA's electrical page says electricity has long been recognized as a serious workplace hazard.
Related terms
Free tools for this
Governing OSHA standards
More Construction terms
The part of Title 29 of the Code of Federal Regulations that contains OSHA's General Industry standards, the default rulebook for most American workplaces (manufacturing, warehousing, healthcare, etc.) that are not covered by the construction, maritime or agriculture standards. It includes core rules such as Hazard Communication (1910.1200) and the air contaminant limits (1910.1000). Construction work is covered by Part 1926, which 1910.12(a) adopts as standards for every employee engaged in construction work, and some requirements are the same in both parts: 1926.59 says the HazCom requirements for construction are identical to those of 1910.1200.
29 CFR 1926The part of Title 29 of the Code of Federal Regulations that contains OSHA's Construction standards, the “Safety and Health Regulations for Construction.” It applies to construction work, which 1910.12(b) defines as work for construction, alteration, and/or repair, including painting and decorating, with construction-specific rules for fall protection (Subpart M), scaffolds (Subpart L), excavations (Subpart P), electrical (Subpart K) and more. OSHA decides by the activity being performed and not only by the employer's general business. Some general-industry (1910) standards apply to construction because 1926 adopts them (HazCom through 1926.59) or because 1910 identifies them as applicable to construction; OSHA's Field Operations Manual says a hazard in construction work that no specific 1926 standard covers is not normally cited under 1910 unless that standard has been identified as applicable to construction.
Anchor PointThe secure attachment point a personal fall arrest system (PFAS) ties off to. Under 29 CFR 1926.502(d)(15), anchorages used for attachment of personal fall arrest equipment are independent of any anchorage being used to support or suspend platforms and capable of supporting 5,000 pounds or more pounds per employee attached, or are designed, installed and used as part of a complete personal fall arrest system that maintains a safety factor of two or more, under the supervision of a qualified person.
Atmospheric TestingMeasuring the air in a confined space with an instrument before and during entry, as part of the evaluation of a permit space (1926.1204(e)) or of the alternate procedures for a space whose only hazard is atmospheric and is controlled by forced air ventilation, which call for a calibrated direct-reading instrument (1926.1203(e)(2)(iii)). Testing is done in a set order: first oxygen, then combustible gases and vapors, then toxic gases and vapors (1926.1204(e)(3)). Whether an atmosphere is hazardous is defined in 1926.1202: flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit; oxygen below 19.5 percent or above 23.5 percent; a substance above its dose or permissible exposure limit; or any other atmospheric condition that is immediately dangerous to life or health. Readings within those ranges are one condition of an entry and are not enough on their own: the classification of the space, the permit, isolation, ventilation, an attendant and rescue also apply.
BenchingA method of protecting employees from cave-ins by excavating the sides of an excavation to form one or a series of horizontal levels or steps, usually with vertical or near-vertical surfaces between levels (1926.650(b)). Benching is one of the sloping and benching systems whose slopes and configurations are selected under 1926.652(b), by one of four options: a slope not steeper than 1½H:1V (Option 1), Appendices A and B (Option 2), other tabulated data (Option 3), or a design approved by a registered professional engineer (Option 4). Appendix B to Subpart P lists benched configurations for Type A and Type B soil in excavations 20 feet or less in depth, and it lists no benched configuration for Type C soil.
Competent Person (Excavation)In OSHA's excavation standard (Subpart P), a competent person is one who is capable of identifying existing and predictable hazards in the surroundings, or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them (1926.650(b)). The competent person inspects excavations, the adjacent areas and protective systems before the start of work, as needed throughout the shift (not a continuous watch), and after every rainstorm or other hazard increasing occurrence, when employee exposure can be reasonably anticipated (1926.651(k)(1)). Exposed employees are removed from the hazardous area when the competent person finds evidence of a possible cave-in or another hazardous condition, until the necessary precautions have been taken (1926.651(k)(2)). When Appendix A to Subpart P applies, a competent person also classifies each soil and rock deposit as stable rock, Type A, Type B or Type C, based on a visual and a manual analysis.
Confined SpaceA space that is large enough and so configured that an employee can bodily enter it, has limited or restricted means for entry and exit, and is not designed for continuous employee occupancy (1926.1202). It is a permit space (also called a PRCS) if it has one or more of these characteristics: it contains or has a potential to contain a hazardous atmosphere; it contains a material that has the potential for engulfing an entrant; it has an internal configuration such that an entrant could be trapped or asphyxiated by inwardly converging walls or by a floor that slopes downward and tapers to a smaller cross-section; or it contains any other recognized serious safety or health hazard. A competent person identifies the confined spaces and the permit spaces before work begins (1926.1203(a)). An employer that decides to have employees enter a permit space has a written permit space program (1926.1203(d)), or uses the alternate procedures of 1926.1203(e) when their conditions are met, and a permit space can be reclassified as a non-permit confined space only when a competent person determines that the requirements of 1926.1203(g) are met.
Controlling EmployerUnder OSHA's Multi-Employer Citation Policy (CPL 02-00-124), a controlling employer is an employer who has general supervisory authority over the worksite, including the power to correct safety and health violations itself or to have others correct them. Control can be established by contract or, in the absence of explicit contractual provisions, by the exercise of control in practice. In the policy's examples the controlling employer is a general contractor or a construction manager, and an architect or engineer is one only if the breadth of its involvement is sufficient. The policy works in two steps: first the employer's role (creating, exposing, correcting or controlling), then whether its actions were sufficient for that role. A controlling employer has a duty to exercise reasonable care to prevent and detect violations on the site, and it can be cited for another employer's violation of an OSHA standard even when none of its own employees are exposed, but only when it did not meet that duty.
Sources & verification
- 29 CFR 1926 Subpart K (eCFR / OSHA.gov)
- 29 CFR 1926.416(a)(1) (eCFR / OSHA.gov)
- OSHA: Construction Focus Four Training
- OSHA: Electrical (Safety and Health Topics)
- eCFR: 29 CFR 1926.416, General requirements (electrical)
Checked against the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
A related free tool
The free LOTO Procedure Generator covers a task related to Electrocution. Read the rule above first, then use the tool for your own workplace.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.