General safety term · Glossary
Flash Point
Verified vs OSHA sources · 2026-10-27
The minimum temperature at which a liquid gives off vapor in sufficient concentration to form an ignitable mixture with air near the surface of the liquid, as determined by a test method identified in Appendix B.6.3 of 29 CFR 1910.1200. It is a measured test result, so it describes the test conditions and not every real condition. In the Hazard Communication Standard it defines a flammable liquid (a liquid with a flash point of not more than 93 °C, 199.4 °F) and sorts flammable liquids into four categories (Appendix B.6.2). At a lower flash point, the liquid gives off an ignitable mixture of vapor and air at a lower temperature.
Also known as: flashpoint, FP
On this page
Flash Point at a glance
- Flash point is determined by a method identified in Appendix B.6.3: ASTM D56-05, D3278, D3828 or D93-08, any method specified in 1910.106(a)(14), or another method specified in GHS Revision 7, Chapter 2.6.
- Appendix B.6.2 sorts flammable liquids by flash point (FP) and initial boiling point (IBP): Category 1 is FP below 23 °C (73.4 °F) with IBP of 35 °C (95 °F) or less; Category 2 is FP below 23 °C with IBP above 35 °C; Category 3 is FP from 23 °C up to and including 60 °C (140 °F); Category 4 is FP above 60 °C up to and including 93 °C (199.4 °F). The boiling point separates Categories 1 and 2 only. Categories 3 and 4 depend on flash point alone.
- Flash points differ between products and between grades of the same fuel. Read the value for the product on site in Section 9 of its SDS (item (h), Flash point), and the classification in Section 2 (Appendix D).
- Flash point is a key parameter and not the whole decision. It sets the category, the signal word and the hazard statement for flammable liquids (Appendix C.4.19). Storage and use provisions in 1910.106 also depend on the container type, the quantity and the installation, and a product's label follows all of its hazard classes.
In plain English
The lowest temperature at which a liquid gives off enough vapor to form an ignitable mixture with air. A lower flash point means ignitable vapor at a lower temperature. It is a standard test result, and real conditions can differ.
What the rule says
“Flash point means the minimum temperature at which a liquid gives off vapor in sufficient concentration to form an ignitable mixture with air near the surface of the liquid, as determined by a method identified in Section B.6.3 of this appendix.”
In context
An industrial-hygiene, exposure-control, or program-management concept that applies across OSHA standards and workplaces.
Where this is written in OSHA's rules
- 29 CFR 1910.1200 App B.6Read on eCFR / OSHA.gov
- 29 CFR 1910.1200Read on eCFR / OSHA.gov
Example
In this invented illustration, the SDS of a solvent gives a flash point of 20 °C (68 °F) and an initial boiling point of 56 °C (133 °F). The flash point is below 23 °C and the initial boiling point is above 35 °C, so Appendix B.6.2 puts it in Category 2. For a different liquid, a reported flash point of 55 °C puts it in Category 3 and one of 62 °C in Category 4. The category follows the value that the SDS reports for the actual product and the test method behind it, not the name of the liquid.
Why it matters
Flash point sets a liquid's category, and with it the signal word and hazard statement on the label (Appendix C.4.19), and 1910.106 uses categories in several of its storage and use provisions. How a liquid is actually stored and handled also depends on the container type, the quantity, the installation and other provisions, and a label follows all of the product's hazard classes. A wrong flash point value can put a liquid in the wrong category.
Flash point vs. autoignition vs. boiling point
Flash point is the minimum temperature at which a liquid gives off vapor in sufficient concentration to form an ignitable mixture with air near its surface (Appendix B.6.1). It is found with a standard test method. Autoignition temperature is a different property, also listed in Section 9 of the SDS. Boiling point is where the liquid boils; for flammable liquids the initial boiling point only separates Category 1 from Category 2 when the flash point is below 23 °C.
HCS flammable-liquid categories by flash point (FP) and initial boiling point (IBP) (Appendix B.6.2), with the label elements the HCS assigns
| Category | Flash point | Initial boiling point | Label |
|---|---|---|---|
| 1 (most hazardous) | < 23 °C (73.4 °F) | ≤ 35 °C (95 °F) | Danger; flame pictogram |
| 2 | < 23 °C (73.4 °F) | > 35 °C (95 °F) | Danger; flame pictogram |
| 3 | ≥ 23 °C and ≤ 60 °C (140 °F) | Not used | Warning; flame pictogram |
| 4 | > 60 °C and ≤ 93 °C (199.4 °F) | Not used | Warning, “Combustible liquid”; no pictogram |
Flash Point: frequently asked questions
- What is Flash Point?
- The minimum temperature at which a liquid gives off vapor in sufficient concentration to form an ignitable mixture with air near the surface of the liquid, as determined by a test method identified in Appendix B.6.3 of 29 CFR 1910.1200. It is a measured test result, so it describes the test conditions and not every real condition. In the Hazard Communication Standard it defines a flammable liquid (a liquid with a flash point of not more than 93 °C, 199.4 °F) and sorts flammable liquids into four categories (Appendix B.6.2). At a lower flash point, the liquid gives off an ignitable mixture of vapor and air at a lower temperature.
- What is the difference between flash point and autoignition temperature?
- Flash point is the minimum temperature at which a liquid gives off vapor in sufficient concentration to form an ignitable mixture with air near its surface, found with a standard test method. Autoignition temperature is a separate property, also listed in Section 9 of the SDS. HCS classification of flammable liquids uses flash point, with initial boiling point for Categories 1 and 2.
- What flash point makes a liquid 'flammable' under the HCS?
- Under OSHA's GHS-aligned HazCom standard, a flammable liquid is a liquid with a flash point of not more than 93 °C (199.4 °F) (Appendix B.6.1). A flash point below 23 °C with an initial boiling point of 35 °C (95 °F) or less puts it in Category 1, the most hazardous category (Appendix B.6.2).
- Where do I find a chemical's flash point?
- In Section 9 (Physical and chemical properties) of its safety data sheet, item (h), Flash point. The resulting flammable liquid category appears in Section 2 (Hazard identification) (Appendix D).
- Does every flammable liquid category carry the flame pictogram?
- No. Under Appendix C.4.19, Categories 1 to 3 carry the flame pictogram, with the signal words Danger for Categories 1 and 2 and Warning for Category 3. Category 4 carries the signal word Warning and the hazard statement “Combustible liquid” with no pictogram.
Related terms
Free tools for this
Governing OSHA standards
More General Safety terms
An arc flash is the sudden release of thermal energy from an electrical arc fault, a short circuit that jumps through the air between energized parts. The arc can reach temperatures over 35,000°F (nearly four times the surface of the sun), causing severe burns, igniting clothing, and driving an explosive pressure wave known as the arc blast. OSHA has no single “arc-flash standard”. Its electrical rules apply instead: 29 CFR 1910.333 and 1910.335 for work practices and PPE, and 1910.269 for electric power work. The analysis method (arc-flash boundary, incident energy, arc-rated PPE) comes from NFPA 70E, a consensus standard that OSHA has not adopted; OSHA and employers can use it as a guide for hazard analysis and controls (OSHA interpretation 2006-11-14).
Experience Modification Rate (EMR)A workers' compensation insurance multiplier that adjusts an employer's premium to reflect its own payroll and loss record compared with the expected experience of employers in the same classification. A mod of 1.00 leaves the premium unchanged (the unity mod). A mod above 1.00, a debit mod, raises the premium, and one below 1.00, a credit mod, lowers it. The mod multiplies the premium calculated before the modification. It's set by rating bureaus (NCCI or a state bureau) under each state's rules, not by OSHA.
Action LevelAn airborne concentration of a substance, below the exposure limit, at which certain provisions of an OSHA standard begin to apply. Which provisions depend on the standard: they can include exposure assessment or monitoring, training and medical surveillance, each with its own trigger. The action level is set in each standard. For respirable crystalline silica it is 25 µg/m³ as an 8-hour TWA, half the 50 µg/m³ PEL; for lead it is 30 µg/m³ against a PEL of 50 µg/m³ (1910.1025), and for formaldehyde 0.5 ppm against a PEL of 0.75 ppm (1910.1048).
Administrative ControlsChanges to how and when work is done that reduce a worker's exposure without changing the hazard itself. NIOSH places administrative controls fourth in the hierarchy of controls, below elimination, substitution and engineering controls and above personal protective equipment, and gives examples such as work process training, job rotation, adequate rest breaks, limiting access to hazardous areas or machinery, and adjusting line speeds. Housekeeping, written procedures and signage fit the same description. The hierarchy is a preference order. What an OSHA standard calls for is in that standard's own words.
Biological Exposure Index (BEI)An ACGIH guidance value for evaluating biological monitoring results. A BEI generally represents the level of a determinant most likely to be observed in specimens from healthy workers exposed at the TLV-TWA level. The determinant can be the chemical itself, one or more metabolites, or a characteristic, reversible biochemical change induced by the chemical, measured in a specimen such as blood, urine or exhaled breath. BEIs do not indicate a sharp distinction between hazardous and nonhazardous exposures, and they are advisory: an OSHA standard that calls for biological monitoring sets its own terms.
California Proposition 65California's Safe Drinking Water and Toxic Enforcement Act of 1986. As OEHHA describes it, businesses give a “clear and reasonable” warning before knowingly and intentionally exposing anyone to a chemical on the state's list, unless the business can show that the anticipated exposure will not pose a significant risk of cancer or is significantly below levels observed to cause birth defects or other reproductive harm. The list has grown to approximately 900 chemicals. The warning requirement takes effect one year after a chemical is listed, and businesses with less than 10 employees and government agencies are exempt. The law also prohibits knowingly discharging listed chemicals into sources of drinking water. It is a California law, and the test is the exposure a business causes, not the presence of a listed chemical alone.
CAS NumberA numerical identifier assigned by CAS (Chemical Abstracts Service, a division of the American Chemical Society) to a substance registered in the CAS REGISTRY. CAS describes a CAS Registry Number as a unique and unambiguous identifier for a specific substance. Substances are added when they are identified in literature being indexed for the CAS Content Collection or when an entity requests a number for a novel substance. The number has up to 10 digits in three groups separated by hyphens: 2 to 7 digits, 2 digits, and one check digit (for example, 67-64-1 for acetone). CAS is the source and final authority for CAS Registry Numbers, and other resources may associate an incorrect number with a compound.
Ceiling LimitAn exposure limit that may not be exceeded at any instant during the workday. In OSHA's Z-tables it is marked with a “C” before the value. Unlike an 8-hour TWA (an average) or a 15-minute STEL, a Table Z-1 ceiling applies to a single moment; if instantaneous monitoring is not feasible, it is assessed as a 15-minute time-weighted average that may not be exceeded at any time during the working day. Table Z-2 instead uses an acceptable ceiling concentration with a separate acceptable maximum peak allowed for a limited time (1910.1000(a)(1), (b)(2)-(3)).
Sources & verification
- 29 CFR 1910.1200 App B.6 (eCFR / OSHA.gov)
- 29 CFR 1910.1200 (eCFR / OSHA.gov)
- OSHA: Appendix B to §1910.1200, Physical hazard criteria (B.6 Flammable liquids)
- OSHA: Appendix C to §1910.1200, Allocation of label elements (C.4.19 Flammable liquids)
- OSHA: Appendix D to §1910.1200, Safety data sheets (Sections 2 and 9)
- eCFR: 29 CFR 1910.106, Flammable liquids (including (a)(14))
Checked against the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
A related free tool
The free Flammable Liquid GHS Category Classifier covers a task related to Flash Point. Read the rule above first, then use the tool for your own workplace.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.