Flammable Liquid
Verified vs OSHA sources · 2026-10-05
Under OSHA's HazCom standard, a liquid with a flash point at or below 93°C (199.4°F). GHS/HCS sorts flammable liquids into four categories by flash point (FP) and initial boiling point (BP): Category 1 is the most dangerous (very low flash point and boiling point, e.g. gasoline), Category 4 the least. The lower the flash point, the more readily the liquid gives off ignitable vapor at ordinary temperatures.
Also known as: Class I liquid (legacy)
On this page
Flammable Liquid at a glance
- Definition ceiling: flash point ≤ 93°C (199.4°F).
- Category 1: FP < 23°C (73.4°F) and BP ≤ 35°C (95°F) — e.g., gasoline.
- Category 2: FP < 23°C (73.4°F) and BP > 35°C (95°F).
- Category 3: FP ≥ 23°C and ≤ 60°C (73.4–140°F); Category 4: FP > 60°C and ≤ 93°C (140–199.4°F). A flash point of exactly 60°C falls in Category 3.
In plain English
A liquid that catches fire easily — technically one whose flash point is 93°C (199.4°F) or lower. Gasoline (very low flash point) is the classic high-hazard example; diesel sits at the mild end of the flammable range.
What the rule says
“Flammable liquid means a liquid having a flash point of not more than 93 °C (199.4 °F).”
In context
An industrial-hygiene, exposure-control, or program-management concept that applies across OSHA standards and workplaces.
Where this is written in OSHA's rules
- 29 CFR 1910.1200 App B.6Read on eCFR / OSHA.gov
Example
Gasoline has a flash point around −43°C and a low boiling point, so it's Category 1 — it releases ignitable vapor far below room temperature. Diesel straddles the 60°C line: below it the grade is Category 3, above it Category 4 — the SDS value decides. Either way it needs to be heated before it will readily ignite.
Why it matters
Flash point drives storage, ventilation, bonding/grounding, and ignition-control requirements — misjudging a liquid's category leads to under-controlled fire and explosion risk. Because HazCom classification (App B.6) also sets the GHS02 pictogram and signal word on the label, getting the category right is both a fire-safety and a labeling-compliance issue.
Flammable vs. combustible liquid
In the GHS/HazCom framework, all liquids up to a 93°C flash point are “flammable liquids” (Categories 1–4). The older term “combustible liquid” (flash point at or above ~38–60°C in legacy 1910.106 usage) roughly corresponds to the higher-flash-point end — but under HazCom labeling, the four flammable-liquid categories are what determine the pictogram and signal word.
GHS flammable liquid categories (by flash point / boiling point)
| Category | Flash point | Boiling point | Example |
|---|---|---|---|
| 1 | < 23°C (73.4°F) | ≤ 35°C (95°F) | Gasoline |
| 2 | < 23°C (73.4°F) | > 35°C (95°F) | Acetone |
| 3 | 23–60°C (73.4–140°F) | — | Kerosene |
| 4 | 60–93°C (140–199.4°F) | — | Diesel |
Flammable Liquid: frequently asked questions
- What is a flammable liquid under OSHA?
- A liquid with a flash point of not more than 93°C (199.4°F), per 1910.1200 Appendix B.6. GHS/HazCom divides flammable liquids into four categories by flash point and boiling point.
- What's the difference between the flammable liquid categories?
- Category 1 has the lowest flash point (< 23°C) and boiling point (≤ 35°C) and is the most hazardous; Categories 2–4 have progressively higher flash points, with Category 4 topping out at 93°C.
- Is diesel a flammable liquid?
- Diesel's flash point (~52–65°C) places it at the mild end — typically Category 3 or 4. It's still a flammable liquid under HazCom, but it needs heating before it readily ignites, unlike Category 1 gasoline.
Related terms
Free tools for this
Governing OSHA standards
More General Safety terms
An arc flash is the sudden release of thermal energy from an electrical arc fault — a short circuit that jumps through the air between energized parts. The arc can reach temperatures over 35,000°F (nearly four times the surface of the sun), causing severe burns, igniting clothing, and driving an explosive pressure wave known as the arc blast. OSHA sets no single “arc-flash standard”: the analysis method — the arc-flash boundary, incident energy, and arc-rated PPE — comes from the NFPA 70E consensus standard, which OSHA enforces through its electrical-PPE rules (29 CFR 1910.335, 1910.269) and the General Duty Clause.
Action LevelAn airborne concentration of a substance — typically half the PEL — at which certain provisions of an OSHA standard kick in (such as exposure monitoring, training, and medical surveillance), even though it is below the legal exposure limit. For respirable crystalline silica the action level is 25 µg/m³ as an 8-hour TWA, half the 50 µg/m³ PEL.
Administrative ControlsChanges to how and when work is done — job rotation, scheduling, safe work practices, housekeeping, training, and signage — that reduce a worker's exposure without altering the hazard itself. They are the fourth tier of the hierarchy of controls, below engineering controls and above PPE.
Biological Exposure Index (BEI)An ACGIH guidance value for interpreting biological monitoring results — the concentration of a chemical (or its metabolite) measured in a worker's blood, urine, or exhaled breath. A BEI represents the level most likely found in a healthy worker whose inhalation exposure was at the TLV, so it measures the dose the body actually absorbed, not just what's in the air.
California Proposition 65California's Safe Drinking Water and Toxic Enforcement Act of 1986. It requires businesses to warn Californians before exposing them to any of the ~900+ listed chemicals known to the state to cause cancer, birth defects, or other reproductive harm, and prohibits discharging those chemicals into drinking-water sources. It's a California law, but it reaches nearly any product sold there.
CAS NumberA unique numerical identifier assigned by the Chemical Abstracts Service (a division of the American Chemical Society) to every distinct chemical substance. It has the format of up to seven digits, a dash, two digits, a dash, and a final check digit (e.g., 67-64-1 for acetone). Because chemical names vary, the CAS number is the unambiguous global key used on SDSs, inventories, and regulations.
Ceiling LimitAn exposure limit that must not be exceeded at any instant during the workday — the strictest type of OSHA exposure limit. In OSHA's Z-tables it is marked with a “C” before the value. Unlike an 8-hour TWA (an average) or a 15-minute STEL, a ceiling applies to a single moment.
Chemical CompatibilityWhether two or more chemicals can be safely stored or used near each other without reacting dangerously — releasing heat, toxic gas, or fire. Incompatible chemicals must be physically separated (segregated) in storage. Each chemical's incompatibilities are listed in Section 10 of its SDS, and compatibility drives storage layout and spill response.
Sources & verification
- 29 CFR 1910.1200 App B.6 (eCFR / OSHA.gov)
- OSHA — 1910.1200 Appendix B (Physical Criteria)
- OSHA — 1910.106 (Flammable liquids)
Reviewed by HazComFast against eCFR, OSHA.gov, NIOSH, and the Federal Register. Last reviewed 2026-10-05. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
Put Flammable Liquid into practice
Don't just read the definition — apply it. Use the free HazCom Audit Checklist (2026) to put real numbers behind Flammable Liquid for your jobsite.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA does not give advance notice of inspections (29 CFR 1903.6). Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.