GHS / HazCom term · Glossary
GHS01 (Exploding Bomb)
Verified vs OSHA sources · 2026-10-27
The GHS hazard pictogram showing an exploding bomb. In OSHA's Appendix C (Figure C.1 and table C.4) it appears for unstable explosives and explosives of Divisions 1.1 to 1.4, and for self-reactive substances and organic peroxides Type A (bomb alone) and Type B (bomb and flame together). Divisions 1.5 and 1.6 carry no pictogram. On US labels the symbol is black on a white background inside a square red frame set at a point (C.2.3.1).
Also known as: exploding bomb, explosives pictogram
On this page

Download the exploding bomb pictogram
Free to use, no attribution needed. All nine pictograms · Put it on a label
GHS01 (Exploding Bomb) at a glance
- Covers unstable explosives and explosives of Divisions 1.1 to 1.4, and self-reactive substances and organic peroxides Types A and B (Appendix C, C.4.14, C.4.21, C.4.28). Divisions 1.5 and 1.6 carry no pictogram.
- Signal word depends on the class and category: “Danger” for unstable explosives, Divisions 1.1 to 1.3, and Types A and B; “Warning” for Division 1.4; Division 1.5 has “Danger” without a pictogram; Division 1.6 has no signal word. If another hazard on the same product carries “Danger,” “Warning” does not appear (C.2.1.1).
- Type B pairs the bomb with the flame: self-reactive substances Type B and organic peroxides Type B carry both GHS01 and GHS02. Types C to F use the flame alone.
- Desensitized explosives classified under B.17 use the flame (GHS02), not this pictogram, as long as they stay desensitized. Their label warns that the risk of explosion increases if the desensitizing agent is reduced.
In plain English
The “this can blow up” symbol. It flags explosives and the most reactive self-reactive substances and organic peroxides. What the hazard is depends on the class and category: from a mass explosion hazard (Division 1.1) to a fire or projection hazard (Division 1.4). The statement and the signal word that go with the symbol come from the class and category, and some products carry the flame symbol too.
What the source says, in summary
Explosives, Division 1.1: “Explosive; mass explosion hazard.” Self-reactive substances and organic peroxides, Type A: “Heating may cause an explosion.”
In context
A classification or labeling concept from the UN Globally Harmonized System, adopted into US law through OSHA's Hazard Communication Standard (29 CFR 1910.1200) and its appendices.
Where this is written in OSHA's rules
- 29 CFR 1910.1200 App CRead on eCFR / OSHA.gov
Example
An organic peroxide classified as Type B carries two pictograms, the exploding bomb (GHS01) and the flame (GHS02), with the signal word “Danger” and, in OSHA's table C.4.28, the hazard statement “Heating may cause an explosion.” The pictograms, signal word and statements come from the classification, so they are confirmed against the product's safety data sheet. A Type A product carries the bomb alone with the same statement, and Types C to F carry the flame alone with “Heating may cause a fire.”
Why it matters
GHS01 marks hazards for which storage, heat and shock controls matter, and the label elements follow the class and category. Checking the class, the packaging and the precautionary statements in C.4.14, C.4.21 or C.4.28 for the product at hand is the practical step. A wrong or missing pictogram misstates the hazard on the label, and classification and labeling are covered by 1910.1200.
Exploding bomb (GHS01) vs. flame (GHS02) for reactives
The most reactive self-reactive substances and organic peroxides use GHS01: Type A with the bomb alone, Type B with the bomb and the flame together. The less reactive types (C to F) use the flame GHS02 alone. Desensitized explosives classified under B.17 also use the flame, as long as they stay desensitized, because the label statement then describes a fire, blast or projection hazard and warns that the explosion risk increases if the desensitizing agent is reduced.
Classes that use the exploding-bomb pictogram (GHS01), Appendix C
| Hazard class and category | Pictogram | Signal word · label statement |
|---|---|---|
| Unstable explosive | Exploding bomb | Danger · Unstable explosive |
| Explosives, Division 1.1 | Exploding bomb | Danger · Explosive; mass explosion hazard |
| Explosives, Division 1.2 | Exploding bomb | Danger · Explosive; severe projection hazard |
| Explosives, Division 1.3 | Exploding bomb | Danger · an explosive fire, blast or projection statement |
| Explosives, Division 1.4 | Exploding bomb | Warning · Fire or projection hazard |
| Explosives, Divisions 1.5 and 1.6 | No pictogram | Division 1.5: Danger · May mass explode in fire. Division 1.6: no signal word or statement |
| Self-reactive substances, Type A | Exploding bomb | Danger · Heating may cause an explosion |
| Self-reactive substances, Type B | Exploding bomb and flame | Danger · Heating may cause a fire or explosion |
| Organic peroxides, Type A | Exploding bomb | Danger · Heating may cause an explosion |
| Organic peroxides, Type B | Exploding bomb and flame | Danger · Heating may cause an explosion |
GHS01 (Exploding Bomb): frequently asked questions
- What is GHS01 (Exploding Bomb)?
- The GHS hazard pictogram showing an exploding bomb. In OSHA's Appendix C (Figure C.1 and table C.4) it appears for unstable explosives and explosives of Divisions 1.1 to 1.4, and for self-reactive substances and organic peroxides Type A (bomb alone) and Type B (bomb and flame together). Divisions 1.5 and 1.6 carry no pictogram. On US labels the symbol is black on a white background inside a square red frame set at a point (C.2.3.1).
- What does the exploding bomb pictogram mean?
- It marks an explosion-related hazard: unstable explosives, explosives of Divisions 1.1 to 1.4, and the most reactive self-reactive substances and organic peroxides (Types A and B). The hazard ranges from mass explosion (Division 1.1) to fire or projection hazards (Division 1.4), and the statement on the label says which one applies (Appendix C, C.4.14, C.4.21, C.4.28).
- Why don't all reactive chemicals use the exploding bomb symbol?
- Appendix C assigns it only to the most explosive categories. Less reactive self-reactive substances and organic peroxides (Types C to F) use the flame pictogram (GHS02), as do desensitized explosives classified under B.17 while they stay desensitized. Type B self-reactive substances and organic peroxides carry both symbols.
- Is GHS01 required by OSHA?
- It is one of the eight symbols in OSHA's Hazard Communication Standard (Appendix C, Figure C.1), and it appears on a label when the classification calls for it. Labels on shipped containers carry the pictograms for the classified hazards (1910.1200(f)(1)). Workplace labeling can instead use the product identifier with words, pictures or symbols that give general hazard information alongside the other information available to employees (1910.1200(f)(6)), so the symbol is not automatically on every workplace label.
Related terms
Free tools for this
Governing OSHA standards
More GHS terms
A GHS health-hazard class for serious adverse health effects (that is, lethality) occurring after a single or short-term oral, dermal or inhalation exposure to a substance or mixture (29 CFR 1910.1200 Appendix A, A.1.1). Substances are allocated to one of four hazard categories by route (oral, dermal, inhalation) using numeric cut-offs for LD50 (oral, dermal) or LC50 (inhalation) values or acute toxicity estimates (ATE). Category 1 is the most toxic. A mixture is classified by a tiered approach (Appendix A, A.1.3).
Aspiration HazardA GHS health-hazard class for severe acute effects such as chemical pneumonia, pulmonary injury or death occurring after aspiration of a substance or mixture (29 CFR 1910.1200 Appendix A, A.10.1.1). Aspiration is the entry of a liquid or solid chemical directly through the oral or nasal cavity, or indirectly from vomiting, into the trachea and lower respiratory system (A.10.1.2). A substance is in Category 1 on reliable and good quality human evidence or, if it is a hydrocarbon, when its kinematic viscosity is 20.5 mm²/s or less at 40 °C. The label elements are the health hazard pictogram (GHS08), the signal word “Danger” and the hazard statement “May be fatal if swallowed and enters airways” (Appendix C, C.4.13).
CarcinogenicityA GHS health-hazard class for the induction of cancer or an increase in the incidence of cancer after exposure to a substance or mixture (29 CFR 1910.1200 Appendix A, A.6.1). Substances are allocated to Category 1 (known or presumed human carcinogens, with sub-categories 1A and 1B) or Category 2 (suspected human carcinogens), based on strength of evidence together with weight of evidence considerations (A.6.2). The label carries the health hazard pictogram (GHS08) with “Danger” for Categories 1A and 1B or “Warning” for Category 2, and a cancer hazard statement (Appendix C, C.4.9).
Chemicals Under PressureA physical-hazard class that OSHA's 2024 HCS update added to Appendix B as B.3.2: liquids or solids (for example pastes or powders) pressurized with a gas at a pressure of 200 kPa (gauge) or more at 20 °C in pressure receptacles other than aerosol dispensers, and not classified as gases under pressure (B.3.2.1). It has three categories, set by the mass percentage of flammable components together with the heat of combustion (Table B.3.2). Categories 1 and 2 carry the gas cylinder (GHS04) and flame (GHS02) pictograms, and Category 3 carries the gas cylinder only (Appendix C, C.4.16). The class does not additionally fall within the scope of flammable gases, aerosols, gases under pressure, flammable liquids or flammable solids, but a product can still fall within other hazard classes (B.3.2, Note 2).
ClassificationUnder 29 CFR 1910.1200(c), classification means to identify the relevant data regarding the hazards of a chemical, review those data to ascertain its hazards, and decide whether it is classified as hazardous under the definition of hazardous chemical. For health and physical hazards it also includes determining the degree of hazard, where appropriate, by comparing the data with the criteria in Appendices A and B. Chemical manufacturers and importers evaluate the chemicals they produce or import and determine the hazard classes and, where appropriate, the category of each class, including hazards tied to a change in the chemical's physical form and to chemical reaction products from known or reasonably anticipated uses (1910.1200(d)(1)). The result feeds the hazard-specific label elements (pictograms, signal word, hazard and precautionary statements) and the safety data sheet.
Corrosive to MetalsA GHS physical-hazard class (29 CFR 1910.1200 Appendix B.16) for a chemical that by chemical action will materially damage, or even destroy, metals (B.16.1). It has a single category, set with the corrosion test in Part III, sub-section 37.4 of the UN Manual of Tests and Criteria: a corrosion rate on steel or aluminum surfaces exceeding 6.25 mm per year at a test temperature of 55 °C. If an initial test on either metal shows the chemical is corrosive, the follow-up test on the other metal is not necessary (Table B.16.1, note). The label carries the corrosion pictogram (GHS05), the signal word “Warning” and the hazard statement “May be corrosive to metals” (H290) (Appendix C, C.4.29). It is a separate hazard from skin corrosion, even though both use GHS05.
Desensitized ExplosivesA physical-hazard class added to Appendix B (B.17) by OSHA's 2024 HCS update (GHS Revision 7): solid or liquid explosive chemicals that are phlegmatized, meaning wetted with water or alcohols, or diluted or dissolved, to form a homogeneous mixture, so that they do not mass explode and do not burn too rapidly (B.17.1). An explosive that is desensitized falls in this class unless it is intended to produce a practical explosive or pyrotechnic effect, has a mass explosion hazard or a corrected burning rate above 1200 kg/min, or has an exothermic decomposition energy below 300 J/g (B.17.2.1). The four categories are set by the corrected burning rate (Table B.17.1), and the label uses the flame pictogram (GHS02), not the exploding bomb (Appendix C, C.4.30).
Globally Harmonized System (GHS)An internationally agreed framework published by the United Nations (the “Purple Book,” first published in 2003) for classifying chemical hazards and communicating them with common classification criteria, pictograms, signal words (Danger / Warning), hazard and precautionary statements for labels, and a safety data sheet format. It is not binding in itself: each country or sector chooses which parts, hazard classes and categories to adopt. In the US, OSHA applies the GHS to workplace chemicals through the Hazard Communication Standard, 29 CFR 1910.1200, aligned with GHS Revision 3 in 2012 and primarily with Revision 7 in 2024. Transport, consumer products and environmental hazards fall under other authorities.
Sources & verification
- 29 CFR 1910.1200 App C (eCFR / OSHA.gov)
- OSHA: Appendix C to §1910.1200, Allocation of Label Elements (Figure C.1; C.4.14, C.4.21, C.4.28)
- eCFR: 29 CFR 1910.1200 (including (f)(1) and (f)(6))
- OSHA: Appendix B to §1910.1200, Physical Hazard Criteria (B.1, B.8, B.15, B.17)
- OSHA: Hazard Communication Pictograms
Checked against the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
A related free tool
The free GHS Label Generator covers a task related to GHS01 (Exploding Bomb). Read the rule above first, then use the tool for your own workplace.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.