What 29 CFR 1926.1052 requires (plain English)
29 CFR 1926.1052 sets the requirements for stairways on construction sites: a routine feature where crews slip, trip and fall, often while carrying materials. It covers when stairs must have rails, how those rails must be built, and the general condition and use rules that keep temporary and permanent construction stairs safe while a project is underway.
The central trigger is the rail requirement: any stairway with four or more risers, or rising more than 30 inches (whichever is less), must be equipped with at least one handrail and a stairrail system along each unprotected side or edge. Stairrail systems installed after March 15, 1991 must be not less than 36 inches high (measured from the tread), and handrails must provide a handhold and sit between 30 and 37 inches above the tread. This companion to 1926.1051, which requires a stairway or ladder wherever there is a break in elevation of 19 inches or more with no ramp, runway, or hoist: makes safe vertical access mandatory on the jobsite.
The standard also addresses condition and use: stairways must be kept clear of hazardous projections and slippery conditions, temporary service stairs with pan-type treads must be filled to the level of the nosing before use, and stairways must not be used until they are fully assembled and their rails are in place. Because workers use stairs constantly and often while carrying materials, unrailed or debris-strewn stairs cause preventable injuries.