What 29 CFR 1926.1051 requires (plain English)
29 CFR 1926.1051 contains the general requirements of Subpart X (Stairways and Ladders). Under paragraph (a), a stairway or ladder must be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. Employees do not use any spiral stairways that will not be a permanent part of the structure on which construction work is being performed ((a)(1)).
When ladders are the only mean of access or exit from a working area for 25 or more employees, or when a ladder is to serve simultaneous two-way traffic, a double-cleated ladder or two or more separate ladders must be provided (1926.1051(a)(2)). When a building or structure has only one point of access between levels, that point of access is kept clear to permit free passage of employees, and when work must be performed or equipment must be used such that free passage at that point is restricted, a second point of access is provided and used (1926.1051(a)(3)). When it has two or more points of access between levels, at least one is kept clear (1926.1051(a)(4)). Paragraph (b) has the employer provide and install all stairway and ladder fall protection systems required by the subpart, and comply with all other pertinent requirements, before employees begin the work that necessitates their installation and use.
1926.1051 works with the rest of Subpart X: the scope and definitions are in 1926.1050, the detailed stairway requirements in 1926.1052, the detailed ladder requirements in 1926.1053, and training in 1926.1060. The handrails, the extension above the landing and the fastening, with their conditions and alternatives, are in 1926.1052 and 1926.1053.