What 29 CFR 1926.1050 requires (plain English)
29 CFR 1926.1050 opens Subpart X, Stairways and Ladders, by defining its scope, application, and terms. It provides that the subpart applies to all stairways and ladders used in construction, alteration, repair (including painting and decorating), and demolition workplaces covered under Part 1926, and that it also sets forth, in specified circumstances, when stairways and ladders must be provided.
The general access rule, set in 1926.1051(a) rather than in this section, is that a stairway or ladder must be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. The alternatives are the four means of access listed in 1926.1051(a).
The section then defines the terms used across Subpart X's substantive sections (among them cleat, double-cleat ladder, equivalent, fixed ladder, handrail, job-made ladder, lower levels, maximum intended load, point of access, portable ladder, stairrail system and unprotected sides and edges) and states that additional requirements for ladders used on or with scaffolds are contained in Subpart L. The specific requirements follow in 1926.1051 (general requirements), 1926.1052 (stairways), and 1926.1053 (ladders), with training in 1926.1060.