Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

29 CFR 1926.1052 · Georgia

Stairways (Construction) Requirements in Georgia

Stairways (Construction) in Georgia: 2026 penalties, who enforces 29 CFR 1926.1052, the paragraphs cited and free tools.

Verified vs OSHA sources · 2026-10-19

GeorgiaConstruction (29 CFR 1926)Federal OSHA Jurisdiction

In Georgia, a serious violation of 29 CFR 1926.1052 (Stairways (Construction)) carries a maximum penalty of $16,550 per violation in 2026, rising to $165,514 for a willful or repeat violation. Stairways (Construction) is enforced for private construction employers by federal OSHA.

In FY2025, federal OSHA cited 29 CFR 1926.1052 7 times in Georgia construction (0.5% of its construction citations there, the 25th most-cited standard there). The paragraph cited most was 1926.1052(c)(1)(ii) with 3 citations.

7

1926.1052 citations in Georgia construction, FY2025

(c)(1)(ii)

paragraph cited most in Georgia (3 citations)

10.2

fatal work injuries per 100,000 full-time workers in construction, Georgia, 2024 (BLS)

Federal OSHA in Georgia: 29 CFR 1926.1052, FY2025

Counted · 2026-09-26

7

citations of 29 CFR 1926.1052 in 6 inspections

$19,261

penalties, current amounts ($24,001 as first proposed)

0.5%

of the 1,541 federal construction citations in Georgia

In FY2025, federal OSHA cited 29 CFR 1926.1052 (Stairways (Construction)) 7 times in inspections of Georgia construction employers. It ranked 25th of the 61 standards cited in them. By classification: 6 serious, 1 other-than-serious. Most-cited paragraphs: 1926.1052(c)(1)(ii) (3), 1926.1052(c)(12) (2), 1926.1052(b)(3) (1).

Counted by HazComFast from the U.S. Department of Labor's OSHA enforcement data (inspection and violation tables, retrieved September 26, 2026): citations issued October 1, 2024 – September 30, 2025 on federal OSHA inspections of construction employers (NAICS 23) in the state, deleted citations excluded, penalties at current amounts. OSHA's own cited-standards tool does not break federal states out; summed over every state, this count matches it within a few citations (6,778 for 1926.501, against 6,772). data.dol.gov

Stairways (Construction) in Georgia: real citations and FY2025 totals

Counted · Oct 21, 2026

The latest 10 inspections in Georgia with an item under 29 CFR 1926.1052 in the Department of Labor's OSHA enforcement data, every industry, newest first. Each line shows the item of that inspection with the largest current penalty under 29 CFR 1926.1052.

  • Jun 17, 2026 · An employer in foundation, structure, and building exterior contractors in Bloomingdale

    1926.1052(c)(1)(i), serious, $2,837 penalty; 2 items under 29 CFR 1926.1052 in this inspection, $2,837 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348897141 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Jun 2, 2026 · An employer in foundation, structure, and building exterior contractors in Statham

    1926.1052(c)(1)(ii), serious, $2,270 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348965021 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • May 29, 2026 · An employer in foundation, structure, and building exterior contractors in Flowery Branch

    1926.1052(c)(1)(ii), serious, $2,837 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348902891 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Apr 6, 2026 · An employer in foundation, structure, and building exterior contractors in Braselton

    1926.1052(c)(1)(ii), serious, $2,894 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348848169 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Mar 26, 2026 · An employer in foundation, structure, and building exterior contractors in Hoschton

    1926.1052(c)(1)(ii), serious, $1,702 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348818154 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Mar 6, 2026 · An employer in foundation, structure, and building exterior contractors in Braselton

    1926.1052(c)(1)(ii), serious, $1,929 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348746926 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Mar 3, 2026 · RQ CONSTRUCTION, LLC in Saint Marys

    1926.1052(c)(1)(ii), other-than-serious, no penalty. Case closed Mar 31, 2026. Recorded by federal OSHA.

    Inspection activity number 348649047 in the Department of Labor data; industry: Nonresidential Building Construction.

  • Jun 10, 2025 · An employer in foundation, structure, and building exterior contractors in Decatur

    1926.1052(c)(1)(ii), serious, $2,837 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348247883 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • May 22, 2025 · JOEL CONTRACTOR LLC in Pooler

    1926.1052(c)(12), serious, $3,783 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348121542 in the Department of Labor data; industry: Building Finishing Contractors.

  • May 22, 2025 · CORNERSTONE DRYWALL AND PAINT, INC. in Pooler

    1926.1052(c)(12), serious, $2,270 current penalty ($3,783 as first proposed). Case closed Jun 30, 2025. Recorded by federal OSHA.

    Inspection activity number 348120726 in the Department of Labor data; industry: Building Finishing Contractors.

FY2025 in Georgia, every industry

7

citation items under 29 CFR 1926.1052 in 6 inspections

0

items at employers outside construction (7 at construction employers, NAICS 23)

2.1%

of the 335 items under 29 CFR 1926.1052 in the data

From Oct 1, 2024 to Sep 30, 2025, the data record 7 citation items under 29 CFR 1926.1052 at inspected sites in Georgia, in 6 inspections, every industry included. Of the 120 sections of 29 CFR parts 1904, 1910 and 1926 cited in Georgia that year (2,547 citation items in all), 50 drew more items than 29 CFR 1926.1052 and 7 drew as many. By classification: 6 serious, 0 willful, 0 repeat and 1 other-than-serious. All of them were recorded by federal OSHA offices. Of the 36 states and territories with items under 29 CFR 1926.1052 in this data, 13 had more than Georgia and 1 had as many.

Paragraphs cited in Georgia, FY2025
ParagraphItemsShare of the 7
1926.1052(c)(1)(ii)343%
1926.1052(c)(12)229%
1926.1052(b)(3)114%
1926.1052(c)(1)(i)114%

Industry groups with the most items: Foundation, Structure, and Building Exterior Contractors (4); Building Finishing Contractors (2); Residential Building Construction (1). 67% of the 6 inspections with a recorded headcount were at sites with 1 to 10 employees (the headcount of the inspected site, not of the employer).

Quarter by quarter in Georgia

Citation items under 29 CFR 1926.1052 at inspected sites in Georgia, by quarter of issuance
QuarterItems
FY2025 · Oct to Dec 20244
FY2025 · Jan to Mar 20250
FY2025 · Apr to Jun 20253
FY2025 · Jul to Sep 20250
FY2026 · Oct to Dec 20250
FY2026 · Jan to Mar 20263
FY2026 · Apr to Jun 20265
FY2026 · Jul to Sep 20260

FY2026 so far: 8 citation items, against 7 in FY2025. FY2026 is still incomplete in the data extracted Oct 21, 2026: the Department of Labor adds citations with a delay.

29 CFR 1926.1052 in the states next to Georgia

Since October 1, 2024, the data record 15 citation items under 29 CFR 1926.1052 in Georgia; in the states next to it, Tennessee 68 (46 in FY2025), North Carolina 33 (17 in FY2025), Florida 17 (6 in FY2025) and South Carolina 4 (3 in FY2025), while Alabama had none. The latest there:

  • Sep 3, 2026 · K N M CONSTRUCTIONS CORP in Hialeah, Florida

    1926.1052(c)(1)(i), serious, $1,722 current penalty ($2,870 as first proposed). Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349123745 in the Department of Labor data; industry: Nonresidential Building Construction.

  • Sep 3, 2026 · SOUTH POINTE CONSTRUCTION & DEVELOPMENT CO. in Hialeah, Florida

    1926.1052(c)(1)(i), serious, $1,230 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348797481 in the Department of Labor data; industry: Residential Building Construction.

  • Aug 26, 2026 · RYAN HAMMOND, INC. in Fort Myers Beach, Florida

    1926.1052(c)(1), serious, $3,311 current penalty ($6,621 as first proposed). Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348816992 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

From the Department of Labor's OSHA enforcement data, extracted Oct 21, 2026: deleted items left out, 29 CFR numbers only, placed in the state of the inspected site; establishment names as recorded, shown when they name a business or a public body; penalties as recorded on Oct 28, 2026, and they change when a case is settled or contested. These are not figures OSHA publishes for the state, and the live database can change them. Same data source and method as our HazCom enforcement study.

Stairways (Construction) Cases in Georgia

Mulch Manufacturing, Inc.

$6,831 proposed - $4,700 final, grouped citation

Homerville, Georgia - wood products plant · 2023

A fatality inspection opened at the Homerville plant in March 2023, after a worker pulling waste boards off a conveyor was struck in the head by a cant propelled from the outfeed of a gang saw on March 14. The stairway citation has nothing to do with that saw; it came out of the wider walkaround. Inspectors grouped 1926.1052(c)(1), which requires at least one handrail and a stairrail system along each unprotected side of any stairway with four or more risers or rising more than 30 inches, with a walking-working surfaces citation under 1910.28(b)(1)(i) as a single serious item. Grouped that way, the stairway paragraph carries no separate figure: the pair was proposed at $6,831 and closed at $4,700.

OSHA inspection 1656669.015 (Fat/Cat), case closed - OSHA Establishment Search

How Georgia Enforces 29 CFR 1926.1052

Georgia has no State Plan, so federal OSHA has jurisdiction. 29 CFR 1926.1052 is enforced by U.S. Department of Labor compliance officers using standard federal procedures and the federal penalty maximums.

In Georgia, the FY2025 citations under 29 CFR 1926.1052 went most often to Framing Contractors (4) and Drywall and Insulation Contractors (2). Citing instances separately is a discretionary exception: OSHA's instance-by-instance policy of April 17, 2024 allows it for serious or repeat violations, and other-than-serious recordkeeping violations, where the standard's text allows it.

Help and oversight in Georgia

Free, confidential help: OSHA On-Site Consultation

In Georgia, the program is Georgia On-Site Safety and Health Consultation Program (Georgia Tech, Enterprise Innovation Institute). OSHA describes it as “Primarily for smaller businesses, no-cost, confidential consultations help employers identify and address hazards and establish or improve safety and health programs.” It is separate from OSHA enforcement; the employer commits to correcting serious hazards.

Georgia consultation program · OSHA consultation directory

Who inspects private employers here

Federal OSHA, from the Atlanta East Area Office (Atlanta), the Atlanta West Area Office (Atlanta) and the Savannah Area Office (Savannah).

OSHA offices for Georgia

Sources: osha.gov and the state's official statute site, September 26, 2026.

Georgia Penalty Amounts for 29 CFR 1926.1052 (2026)

Reviewed · 2026-10-19

Federal amounts effective January 15, 2025 (29 CFR 1903.15(d)).

Violation type2026 maximumBasis
Serious$16,550Federal max · 29 CFR 1903.15(d)
Willful$165,514Federal max · 29 CFR 1903.15(d)
Repeat$165,514Federal max · 29 CFR 1903.15(d)
Failure to abate$16,550/dayup to $16,550 per day; the total is normally capped at 30 times the daily amount (FOM Ch.6)

Georgia applies the federal OSHA maximums. Amounts are ceilings per violation. Federal OSHA can reduce the proposed penalty for employer size, good faith and history, depending on the violation class and the facts (FOM CPL 02-00-164 Ch. 6). There was no inflation increase for 2026: the 2025 amounts remain in effect (OMB Memo M-26-11).

Key Stairways (Construction) Requirements 29 CFR 1926.1052

  • Install stairs between 30° and 50° from horizontal (1926.1052(a)(2))
  • Equip stairways having four or more risers or rising more than 30 inches, whichever is less, with at least one handrail and one stairrail system along each unprotected side or edge (1926.1052(c)(1))
  • Stairrails installed after March 15, 1991 are not less than 36 inches from the upper surface of the stairrail system to the surface of the tread; when the top edge also serves as a handrail, it is not more than 37 inches nor less than 36 inches (1926.1052(c)(3)(i), (c)(7))
  • Keep riser height and tread depth uniform within each flight of stairs, with variations not over 1/4-inch (1926.1052(a)(3))
  • Provide midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members between the top rail of the stairrail system and the stairway steps (1926.1052(c)(4))
  • Except during stairway construction, allow no foot traffic on pan stairs or skeleton metal stairs unless they are fitted with the temporary treads and landings of 1926.1052(b)(1)-(2)

Who enforces it in Georgia: Federal OSHA inspects private construction employers; Georgia has no State Plan.

The compliance checklist, the paragraphs OSHA cites nationally and what an inspector checks under 29 CFR 1926.1052 are on the 29 CFR 1926.1052 page.

Most-Cited Stairways (Construction) Paragraphs in Georgia, FY2025

Federal OSHA issued 7 citations under 29 CFR 1926.1052 to Georgia construction employers in FY2025. The paragraphs cited most, with the official text. A serious violation carries up to $16,550.

  • 1

    1926.1052(c)(1)(ii) 3 citations

    “One stairrail system along each unprotected side or edge.”

  • 2

    1926.1052(c)(12) 2 citations

    “Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.”

  • 3

    1926.1052(b)(3) 1 citation

    “Treads for temporary service shall be made of wood or other solid material, and shall be installed the full width and depth of the stair.”

  • 4

    1926.1052(c)(1)(i) 1 citation

    “At least one handrail; and”

HazComFast count from the Labor Department's OSHA enforcement data: citations issued in FY2025 to construction employers (NAICS 23), by the paragraph cited. Paragraph text: eCFR, current as of September 24, 2026. data.dol.gov

Georgia Safety & Enforcement Profile

26,559

Federal construction citations (national, FY2025)
1,541 of them in Georgia (HazComFast count)

Federal OSHA

Enforces private construction

  • Construction trades inspected most in Georgia, FY2025: Framing Contractors (290), Roofing Contractors (163) and Siding Contractors (99), out of 885 inspections opened (federal OSHA and State Plan combined).
  • Cited most under 29 CFR 1926.1052 in Georgia, FY2025: Framing Contractors (4), Drywall and Insulation Contractors (2) and New Multifamily Housing Construction (except For-Sale Builders) (1), of 7 citations.
  • Construction fatality rate in Georgia, 2024: 10.2 per 100,000 full-time workers, 14th highest of the 40 states BLS published (all industries: 3.4).

HazComFast count from the Labor Department's OSHA enforcement data: inspections of construction employers (NAICS 23) opened from October 1, 2024 to September 30, 2025, federal OSHA and State Plan combined, grouped by the inspected employer's 2022 NAICS industry. HazComFast count from the Labor Department's OSHA enforcement data: citations issued in FY2025 to construction employers (NAICS 23), grouped by the cited employer's 2022 NAICS industry. Industry names are the Census Bureau's 2022 NAICS titles. data.dol.gov · BLS fatality rates by state, 2024

Free Stairways (Construction) Compliance Tools

Stairways (Construction) FAQ for Georgia

Which Georgia construction trades are cited most under Stairways (Construction)?

In FY2025, federal OSHA issued 7 citations under 29 CFR 1926.1052 to Georgia construction employers, most often to Framing Contractors (4), Drywall and Insulation Contractors (2) and New Multifamily Housing Construction (except For-Sale Builders) (1) (HazComFast count from Labor Department enforcement data, by the cited employer's NAICS industry). Federal OSHA inspects these employers directly, since Georgia has no state plan covering the private sector. For context, federal OSHA issued 1,541 citations across 711 inspections of Georgia construction employers in FY2025 (HazComFast count from Labor Department enforcement data). On a jobsite, the standard on this subject is 29 CFR 1926.1052.

How often is Stairways (Construction) cited on Georgia jobsites?

OSHA's cited-standards tool does not break Georgia out, but the Labor Department's enforcement data do: in FY2025, federal OSHA issued 1,541 citations across 711 inspections of Georgia construction employers, 7 of them under 29 CFR 1926.1052 (HazComFast count). Georgia's fatality figures are shown above.

Who enforces stairway rules (1926.1052) in Georgia?

Federal OSHA. With no State Plan, a compliance officer from OSHA's Atlanta region inspects and cites 1926.1052 directly.

Can I get free OSHA help in Georgia without an inspection?

Yes. OSHA's On-Site Consultation Program in Georgia is Georgia On-Site Safety and Health Consultation Program (Georgia Tech, Enterprise Innovation Institute). OSHA describes it this way: "Primarily for smaller businesses, no-cost, confidential consultations help employers identify and address hazards and establish or improve safety and health programs." Consultations are separate from OSHA enforcement, and the employer commits to correcting serious hazards.

How often does federal OSHA cite 29 CFR 1926.1052 in Georgia construction?

In FY2025, federal OSHA cited 29 CFR 1926.1052 (Stairways (Construction)) 7 times in 6 inspections of Georgia construction employers, with $19,261 in penalties at current amounts ($24,001 as first proposed), 0.5% of the 1,541 citations those inspections produced. It ranked 25th of the 61 standards cited. (HazComFast count from U.S. Department of Labor OSHA enforcement data, retrieved 2026-09-26.)

Want the complete federal guide for this standard?

Compare this combination against any other state and standard with the enforcement risk lookup.

Sources & verification

Penalty amounts and plan-type data were checked on 2026-10-19 against eCFR, OSHA.gov, and the Federal Register. This page is informational and not legal advice; consult the enforcing agency or counsel for your specific situation.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.

Your account keeps working as usual. Cancel anytime.