General safety term · Glossary
Tier II Report
The annual hazardous-chemical inventory report required under EPCRA §312 (SARA Title III) for facilities that store hazardous chemicals at or above the reporting thresholds. It lists the chemicals, quantities, and storage locations, and is due by March 1 each year to the State Emergency Response Commission (SERC), the Local Emergency Planning Committee (LEPC), and the local fire department.
Also known as: Tier 2 report, Emergency and Hazardous Chemical Inventory
On this page
Tier II Report at a glance
- Reporting thresholds: 10,000 lb for a hazardous chemical; 500 lb (or the TPQ, whichever is lower) for an Extremely Hazardous Substance.
- Due by March 1 each year, for chemicals present the prior calendar year.
- Filed with three recipients: the SERC, the LEPC, and the local fire department.
- Triggered when an SDS-bearing chemical is stored at or above the threshold.
In plain English
The yearly “here's what hazardous chemicals we store and where” form facilities send to their state, local planners, and fire department. If you store enough of a hazardous chemical, you have to file it by March 1.
What the source says, in summary
The owner or operator of a facility … shall prepare and submit an emergency and hazardous chemical inventory form (Tier II) to the [SERC], the [LEPC], and the fire department with jurisdiction over the facility … by March 1.
In context
An industrial-hygiene, exposure-control, or program-management concept that applies across OSHA standards and workplaces.
Example
A construction yard stores 15,000 pounds of diesel — above the 10,000-pound hazardous-chemical threshold — so by March 1 it files a Tier II report listing the diesel's maximum and average quantities and storage location with its SERC, LEPC, and fire department.
Why it matters
Tier II is how firefighters know what they're walking into before they respond to your site — which is exactly why the EPA enforces missed filings. Facilities often assume “that's not us,” but common materials (diesel, propane, sulfuric acid in batteries) cross the thresholds, and a missed Tier II is a straightforward EPA penalty.
Two different thresholds (EHS vs. hazardous chemical)
The reporting threshold depends on the chemical. For an ordinary hazardous chemical it's 10,000 pounds. For an Extremely Hazardous Substance (EHS) it's much lower — 500 pounds or the chemical's Threshold Planning Quantity, whichever is less. Using the 10,000-pound figure for an EHS misses the report.
Tier II reporting thresholds
| Chemical type | Reporting threshold |
|---|---|
| Hazardous chemical (non-EHS) | 10,000 lb |
| Extremely Hazardous Substance (EHS) | 500 lb or the TPQ, whichever is lower |
| Due date | March 1 each year |
| Recipients | SERC + LEPC + local fire department |
Tier II Report: frequently asked questions
- What is the Tier II reporting threshold?
- 10,000 pounds for an ordinary hazardous chemical, and 500 pounds (or the Threshold Planning Quantity, whichever is lower) for an Extremely Hazardous Substance. A facility at or above the threshold must file.
- When is the Tier II report due, and to whom?
- By March 1 each year (for chemicals present the prior calendar year), to the State Emergency Response Commission (SERC), the Local Emergency Planning Committee (LEPC), and the local fire department.
- What information goes on a Tier II report?
- The hazardous chemicals stored above the threshold, their maximum and average daily amounts, how they're stored, and where on site — so emergency responders know what's present.
Related terms
Free tools for this
More General Safety terms
An arc flash is the sudden release of thermal energy from an electrical arc fault — a short circuit that jumps through the air between energized parts. The arc can reach temperatures over 35,000°F (nearly four times the surface of the sun), causing severe burns, igniting clothing, and driving an explosive pressure wave known as the arc blast. OSHA sets no single “arc-flash standard”: the analysis method — the arc-flash boundary, incident energy, and arc-rated PPE — comes from the NFPA 70E consensus standard, which OSHA enforces through its electrical-PPE rules (29 CFR 1910.335, 1910.269) and the General Duty Clause.
Action LevelAn airborne concentration of a substance — typically half the PEL — at which certain provisions of an OSHA standard kick in (such as exposure monitoring, training, and medical surveillance), even though it is below the legal exposure limit. For respirable crystalline silica the action level is 25 µg/m³ as an 8-hour TWA, half the 50 µg/m³ PEL.
Administrative ControlsChanges to how and when work is done — job rotation, scheduling, safe work practices, housekeeping, training, and signage — that reduce a worker's exposure without altering the hazard itself. They are the fourth tier of the hierarchy of controls, below engineering controls and above PPE.
Biological Exposure Index (BEI)An ACGIH guidance value for interpreting biological monitoring results — the concentration of a chemical (or its metabolite) measured in a worker's blood, urine, or exhaled breath. A BEI represents the level most likely found in a healthy worker whose inhalation exposure was at the TLV, so it measures the dose the body actually absorbed, not just what's in the air.
California Proposition 65California's Safe Drinking Water and Toxic Enforcement Act of 1986. It requires businesses to warn Californians before exposing them to any of the ~900+ listed chemicals known to the state to cause cancer, birth defects, or other reproductive harm, and prohibits discharging those chemicals into drinking-water sources. It's a California law, but it reaches nearly any product sold there.
CAS NumberA unique numerical identifier assigned by the Chemical Abstracts Service (a division of the American Chemical Society) to every distinct chemical substance. It has the format of up to seven digits, a dash, two digits, a dash, and a final check digit (e.g., 67-64-1 for acetone). Because chemical names vary, the CAS number is the unambiguous global key used on SDSs, inventories, and regulations.
Ceiling LimitAn exposure limit that must not be exceeded at any instant during the workday — the strictest type of OSHA exposure limit. In OSHA's Z-tables it is marked with a “C” before the value. Unlike an 8-hour TWA (an average) or a 15-minute STEL, a ceiling applies to a single moment.
Chemical CompatibilityWhether two or more chemicals can be safely stored or used near each other without reacting dangerously — releasing heat, toxic gas, or fire. Incompatible chemicals must be physically separated (segregated) in storage. Each chemical's incompatibilities are listed in Section 10 of its SDS, and compatibility drives storage layout and spill response.
Sources & verification
Reviewed by HazComFast against eCFR, OSHA.gov, NIOSH, and the Federal Register. Last reviewed 2026-10-05. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
Put Tier II Report into practice
Don't just read the definition — apply it. Use the free Chemical Inventory Template to put real numbers behind Tier II Report for your jobsite.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA does not give advance notice of inspections (29 CFR 1903.6). Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.