General safety term · Glossary
SARA (Superfund Amendments and Reauthorization Act)
The Superfund Amendments and Reauthorization Act of 1986, which amended CERCLA (the Superfund law) on October 17, 1986. EPA says it reflected the agency's experience in administering Superfund during its first six years and made several important changes and additions to the program. One part of SARA, Title III, is the Emergency Planning and Community Right-to-Know Act (EPCRA). So “SARA Title III” and “EPCRA” name the same part of the law, while SARA as a whole is the amendment and reauthorization of the Superfund law and is not EPCRA alone.
Also known as: Superfund Amendments and Reauthorization Act, SARA 1986
On this page
SARA (Superfund Amendments and Reauthorization Act) at a glance
- Enacted October 17, 1986, as an amendment of CERCLA (Superfund). EPA says SARA made several important changes and additions to the program, such as more attention to permanent remedies, more State involvement, and a larger trust fund.
- Title III of SARA is EPCRA. EPA says EPCRA was authorized under Title III of SARA in 1986, and EPCRA sections 301 to 313 cover emergency planning, release notification, hazardous chemical inventory reporting and the Toxics Release Inventory.
- Within EPCRA, inventory reporting under sections 311 and 312 has conditions of its own: the federal rule asks for Tier I information at minimum and Tier II on request, and EPA says most States use the Tier II form (see the EPCRA entry).
- The Toxics Release Inventory (EPCRA section 313) applies to a covered facility, one with 10 or more full-time employees in a listed industry code that meets an activity threshold (40 CFR 372.22).
In plain English
The 1986 law that amended and reauthorized the Superfund cleanup law (CERCLA). One part of it, Title III, is the community right-to-know law called EPCRA. “SARA Title III” and “EPCRA” are the same part, not all of SARA.
What the source says, in summary
The Superfund Amendments and Reauthorization Act amended the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) on October 17, 1986.
In context
An industrial-hygiene, exposure-control, or program-management concept that applies across OSHA standards and workplaces.
Example
An SDS Section 15 that lists a chemical as subject to “SARA 313” points to EPCRA section 313, the Toxics Release Inventory, which is part of SARA Title III. The line only prompts a review of whether the facility is covered. 40 CFR 372.22 looks at the facility's industry code, whether it has 10 or more full-time employees, and whether it manufactured, processed or otherwise used the chemical above a threshold, so the line does not mean that every facility with the chemical files a report.
Why it matters
SARA is the law whose Title III, EPCRA, carries the reporting names that appear on SDSs and in compliance plans: Tier II, TRI and the section numbers 302, 311, 312 and 313. Knowing that SARA Title III is EPCRA keeps the names straight. It does not make the duties one: each EPCRA section has its own conditions, and a release of a CERCLA hazardous substance can raise a notification duty under CERCLA that is separate from EPCRA section 304.
SARA vs. CERCLA vs. EPCRA
CERCLA (1980) is the original Superfund law. SARA (1986) amended CERCLA, and its Title III is EPCRA, the community right-to-know law. So EPCRA is one part of SARA, and SARA amended CERCLA. The three are connected but not interchangeable: SARA covers more than EPCRA, and a release can raise separate notification duties under CERCLA and under EPCRA section 304 (40 CFR 355.30).
SARA and its relatives
| Law | Year | What it does |
|---|---|---|
| CERCLA | 1980 | The Superfund law: cleanup of hazardous substance sites and liability, with its own notification of releases |
| SARA | 1986 | Amended CERCLA on October 17, 1986 and added Title III |
| SARA Title III = EPCRA | 1986 | Community right-to-know: emergency planning, release notification, inventory reporting and the TRI, each under its own conditions |
SARA (Superfund Amendments and Reauthorization Act): frequently asked questions
- What is SARA (Superfund Amendments and Reauthorization Act)?
- The Superfund Amendments and Reauthorization Act of 1986, which amended CERCLA (the Superfund law) on October 17, 1986. EPA says it reflected the agency's experience in administering Superfund during its first six years and made several important changes and additions to the program. One part of SARA, Title III, is the Emergency Planning and Community Right-to-Know Act (EPCRA). So “SARA Title III” and “EPCRA” name the same part of the law, while SARA as a whole is the amendment and reauthorization of the Superfund law and is not EPCRA alone.
- What is SARA Title III?
- SARA Title III is the Emergency Planning and Community Right-to-Know Act (EPCRA). SARA (1986) amended CERCLA and, in its Title III, added the community right-to-know programs: emergency planning, release notification, hazardous chemical inventory reporting and the Toxics Release Inventory. Each has its own conditions for which facilities report.
- What's the difference between SARA and CERCLA?
- CERCLA (1980) is the original Superfund law addressing the cleanup of hazardous substance sites and liability. SARA (1986) is the act that amended and reauthorized CERCLA and, in its Title III, added the community right-to-know provisions (EPCRA).
- Does 'SARA 313' on an SDS mean something specific?
- Yes. It refers to EPCRA section 313, the Toxics Release Inventory, which is part of SARA Title III. It flags that the chemical may be one a covered facility reports. Whether a facility files depends on its industry code, its number of full-time employees and the amount it manufactured, processed or otherwise used (40 CFR 372.22).
Related terms
Free tools for this
More General Safety terms
An arc flash is the sudden release of thermal energy from an electrical arc fault, a short circuit that jumps through the air between energized parts. The arc can reach temperatures over 35,000°F (nearly four times the surface of the sun), causing severe burns, igniting clothing, and driving an explosive pressure wave known as the arc blast. OSHA has no single “arc-flash standard”. Its electrical rules apply instead: 29 CFR 1910.333 and 1910.335 for work practices and PPE, and 1910.269 for electric power work. The analysis method (arc-flash boundary, incident energy, arc-rated PPE) comes from NFPA 70E, a consensus standard that OSHA has not adopted; OSHA and employers can use it as a guide for hazard analysis and controls (OSHA interpretation 2006-11-14).
Experience Modification Rate (EMR)A workers' compensation insurance multiplier that adjusts an employer's premium to reflect its own payroll and loss record compared with the expected experience of employers in the same classification. A mod of 1.00 leaves the premium unchanged (the unity mod). A mod above 1.00, a debit mod, raises the premium, and one below 1.00, a credit mod, lowers it. The mod multiplies the premium calculated before the modification. It's set by rating bureaus (NCCI or a state bureau) under each state's rules, not by OSHA.
Action LevelAn airborne concentration of a substance, below the exposure limit, at which certain provisions of an OSHA standard begin to apply. Which provisions depend on the standard: they can include exposure assessment or monitoring, training and medical surveillance, each with its own trigger. The action level is set in each standard. For respirable crystalline silica it is 25 µg/m³ as an 8-hour TWA, half the 50 µg/m³ PEL; for lead it is 30 µg/m³ against a PEL of 50 µg/m³ (1910.1025), and for formaldehyde 0.5 ppm against a PEL of 0.75 ppm (1910.1048).
Administrative ControlsChanges to how and when work is done that reduce a worker's exposure without changing the hazard itself. NIOSH places administrative controls fourth in the hierarchy of controls, below elimination, substitution and engineering controls and above personal protective equipment, and gives examples such as work process training, job rotation, adequate rest breaks, limiting access to hazardous areas or machinery, and adjusting line speeds. Housekeeping, written procedures and signage fit the same description. The hierarchy is a preference order. What an OSHA standard calls for is in that standard's own words.
Biological Exposure Index (BEI)An ACGIH guidance value for evaluating biological monitoring results. A BEI generally represents the level of a determinant most likely to be observed in specimens from healthy workers exposed at the TLV-TWA level. The determinant can be the chemical itself, one or more metabolites, or a characteristic, reversible biochemical change induced by the chemical, measured in a specimen such as blood, urine or exhaled breath. BEIs do not indicate a sharp distinction between hazardous and nonhazardous exposures, and they are advisory: an OSHA standard that calls for biological monitoring sets its own terms.
California Proposition 65California's Safe Drinking Water and Toxic Enforcement Act of 1986. As OEHHA describes it, businesses give a “clear and reasonable” warning before knowingly and intentionally exposing anyone to a chemical on the state's list, unless the business can show that the anticipated exposure will not pose a significant risk of cancer or is significantly below levels observed to cause birth defects or other reproductive harm. The list has grown to approximately 900 chemicals. The warning requirement takes effect one year after a chemical is listed, and businesses with less than 10 employees and government agencies are exempt. The law also prohibits knowingly discharging listed chemicals into sources of drinking water. It is a California law, and the test is the exposure a business causes, not the presence of a listed chemical alone.
CAS NumberA numerical identifier assigned by CAS (Chemical Abstracts Service, a division of the American Chemical Society) to a substance registered in the CAS REGISTRY. CAS describes a CAS Registry Number as a unique and unambiguous identifier for a specific substance. Substances are added when they are identified in literature being indexed for the CAS Content Collection or when an entity requests a number for a novel substance. The number has up to 10 digits in three groups separated by hyphens: 2 to 7 digits, 2 digits, and one check digit (for example, 67-64-1 for acetone). CAS is the source and final authority for CAS Registry Numbers, and other resources may associate an incorrect number with a compound.
Ceiling LimitAn exposure limit that may not be exceeded at any instant during the workday. In OSHA's Z-tables it is marked with a “C” before the value. Unlike an 8-hour TWA (an average) or a 15-minute STEL, a Table Z-1 ceiling applies to a single moment; if instantaneous monitoring is not feasible, it is assessed as a 15-minute time-weighted average that may not be exceeded at any time during the working day. Table Z-2 instead uses an acceptable ceiling concentration with a separate acceptable maximum peak allowed for a limited time (1910.1000(a)(1), (b)(2)-(3)).
Sources & verification
- EPA: The Superfund Amendments and Reauthorization Act (SARA)
- EPA: Emergency Planning and Community Right-to-Know Act (EPCRA)
- eCFR: 40 CFR 372.22, Covered facilities for toxic chemical release reporting (EPCRA section 313)
- eCFR: 40 CFR 355.30, Emergency release notification (note on CERCLA)
Checked against epa.gov and the eCFR. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
A related free tool
The free Chemical Inventory Template covers a task related to SARA (Superfund Amendments and Reauthorization Act). Read the rule above first, then use the tool for your own workplace.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.