Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

Construction term · Glossary

Sloping

Verified vs OSHA sources · 2026-10-27

An excavation protective system. Under 1926.650(b), sloping is a method of protecting employees from cave-ins by excavating to form sides of an excavation that are inclined away from the excavation so as to prevent cave-ins, and the angle of incline needed varies with the soil type, environmental conditions of exposure and surcharge loads. Under Option 2 of 1926.652(b), Appendix B to Subpart P gives the maximum allowable slope, the steepest incline acceptable for the most favorable site conditions, for excavations less than 20 feet deep: stable rock, vertical (90°); Type A, 3/4:1 (53°); Type B, 1:1 (45°); Type C, 1½:1 (34°). Option 1 of 1926.652(b) is a slope not steeper than 1½H:1V (34°) in any soil.

29 CFR 1926.650(b)

Also known as: sloping system

Sloping at a glance

  • Appendix B, Table B-1 (excavations less than 20 feet deep): stable rock, vertical (90°); Type A, 3/4:1 (53°); Type B, 1:1 (45°); Type C, 1½:1 (34°). Sloping or benching for excavations greater than 20 feet deep is designed by a registered professional engineer (Table B-1, note 3).
  • Type A short-term exception (Table B-1, note 2): a short-term maximum allowable slope of 1/2H:1V (63°) is allowed in Type A excavations 12 feet or less in depth, short term meaning open for 24 hours or less; for Type A excavations greater than 12 feet deep the short-term maximum allowable slope is 3/4H:1V (53°).
  • Actual slope (Appendix B (c)(3)): not steeper than the maximum allowable slope; less steep when there are signs of distress, cut back to a slope 1/2H:1V or more less steep than the maximum; and when surcharge loads from stored material, equipment or traffic are present, a competent person determines how far the actual slope is reduced below the maximum.
  • The maximum allowable slope is defined for the most favorable site conditions (Appendix B (b)). Soil and rock deposits are classified under Appendix A (Appendix B (c)(1)).
  • Option 1 of 1926.652(b): a slope not steeper than 1½H:1V (34°) in any soil, unless the employer uses one of the other options. Benching is different: Appendix B lists no benched configuration for Type C soil.

In plain English

Cutting the trench walls back at an angle instead of straight down. The looser the soil, the flatter the maximum slope Appendix B allows. The actual slope is flatter still when there are signs of distress or extra loads at the edge.

What the rule says

“Sloping (Sloping system) means a method of protecting employees from cave-ins by excavating to form sides of an excavation that are inclined away from the excavation so as to prevent cave-ins.”
29 CFR 1926.650(b)

In context

A concept governed primarily by OSHA's construction standards, 29 CFR Part 1926: the rules that apply on jobsites rather than the general-industry 1910 set.

29 CFR 1926

Where this is written in OSHA's rules

Example

In this invented illustration, a 6-foot-deep excavation in soil classified as Type C has simple slopes at 1½:1, so each wall is cut back 9 feet horizontally from the bottom edge (1½ feet for each foot of depth) and the width at the top is the bottom width plus 18 feet. That is the maximum allowable slope under the most favorable site conditions. The actual slope is flatter when there are signs of distress, and a competent person decides how much flatter it is when surcharge loads from stored material, equipment or traffic are present.

Why it matters

Appendix B ties the slope to the soil classification, so a slope that is acceptable in one soil may be too steep in another: Type A allows 3/4:1 and Type C 1½:1. The maximum allowable slope is for the most favorable site conditions, signs of distress and surcharge loads make the actual slope less steep, and excavations deeper than 20 feet are designed by a registered professional engineer.

Reading the slope ratio (H:V)

The ratio is horizontal distance to vertical rise (H:V), as Appendix B defines it. “1½:1” means 1½ feet back for every 1 foot down, a flatter slope than 1:1. Reading the ratio upside down would cut the wall too steep. A lower first number is steeper; a higher first number is flatter.

Maximum allowable slope by soil type, excavations less than 20 feet deep (Appendix B, Table B-1)

Soil typeMax slope (H:V)Angle
Stable rockVertical90°
Type A3/4 : 1 (short term, 12 feet or less deep: 1/2 : 1)53° (63°)
Type B1 : 145°
Type C1½ : 134°

Sloping: frequently asked questions

What is Sloping?
An excavation protective system. Under 1926.650(b), sloping is a method of protecting employees from cave-ins by excavating to form sides of an excavation that are inclined away from the excavation so as to prevent cave-ins, and the angle of incline needed varies with the soil type, environmental conditions of exposure and surcharge loads. Under Option 2 of 1926.652(b), Appendix B to Subpart P gives the maximum allowable slope, the steepest incline acceptable for the most favorable site conditions, for excavations less than 20 feet deep: stable rock, vertical (90°); Type A, 3/4:1 (53°); Type B, 1:1 (45°); Type C, 1½:1 (34°). Option 1 of 1926.652(b) is a slope not steeper than 1½H:1V (34°) in any soil.
What is the maximum slope for Type C soil?
1½:1 (34° from horizontal) in Table B-1 of Appendix B, meaning 1½ feet of horizontal cutback for each foot of depth, for excavations less than 20 feet deep. It is the maximum under the most favorable site conditions: the actual slope is less steep when there are signs of distress, and a competent person decides how much to reduce it for surcharge loads.
What do the slope ratios like 3/4:1 mean?
They are horizontal to vertical: 3/4:1 means 3/4 foot back for every 1 foot down. A larger first number is a flatter slope. Appendix B gives Type A 3/4:1 (with a short-term 1/2:1 for excavations 12 feet or less deep that are open 24 hours or less), Type B 1:1 and Type C 1½:1.
Can I slope any soil?
Yes. Option 1 of 1926.652(b) allows a slope not steeper than 1½H:1V (34°) in any soil, unless the employer uses one of the other options, and Appendix B gives steeper maximums for stable rock, Type A and Type B once the soil is classified under Appendix A. Sloping or benching of excavations greater than 20 feet deep is designed by a registered professional engineer.

Related terms

Free tools for this

Governing OSHA standards

More Construction terms

29 CFR 1910

The part of Title 29 of the Code of Federal Regulations that contains OSHA's General Industry standards, the default rulebook for most American workplaces (manufacturing, warehousing, healthcare, etc.) that are not covered by the construction, maritime or agriculture standards. It includes core rules such as Hazard Communication (1910.1200) and the air contaminant limits (1910.1000). Construction work is covered by Part 1926, which 1910.12(a) adopts as standards for every employee engaged in construction work, and some requirements are the same in both parts: 1926.59 says the HazCom requirements for construction are identical to those of 1910.1200.

29 CFR 1926

The part of Title 29 of the Code of Federal Regulations that contains OSHA's Construction standards, the “Safety and Health Regulations for Construction.” It applies to construction work, which 1910.12(b) defines as work for construction, alteration, and/or repair, including painting and decorating, with construction-specific rules for fall protection (Subpart M), scaffolds (Subpart L), excavations (Subpart P), electrical (Subpart K) and more. OSHA decides by the activity being performed and not only by the employer's general business. Some general-industry (1910) standards apply to construction because 1926 adopts them (HazCom through 1926.59) or because 1910 identifies them as applicable to construction; OSHA's Field Operations Manual says a hazard in construction work that no specific 1926 standard covers is not normally cited under 1910 unless that standard has been identified as applicable to construction.

Anchor Point

The secure attachment point a personal fall arrest system (PFAS) ties off to. Under 29 CFR 1926.502(d)(15), anchorages used for attachment of personal fall arrest equipment are independent of any anchorage being used to support or suspend platforms and capable of supporting 5,000 pounds or more pounds per employee attached, or are designed, installed and used as part of a complete personal fall arrest system that maintains a safety factor of two or more, under the supervision of a qualified person.

Atmospheric Testing

Measuring the air in a confined space with an instrument before and during entry, as part of the evaluation of a permit space (1926.1204(e)) or of the alternate procedures for a space whose only hazard is atmospheric and is controlled by forced air ventilation, which call for a calibrated direct-reading instrument (1926.1203(e)(2)(iii)). Testing is done in a set order: first oxygen, then combustible gases and vapors, then toxic gases and vapors (1926.1204(e)(3)). Whether an atmosphere is hazardous is defined in 1926.1202: flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit; oxygen below 19.5 percent or above 23.5 percent; a substance above its dose or permissible exposure limit; or any other atmospheric condition that is immediately dangerous to life or health. Readings within those ranges are one condition of an entry and are not enough on their own: the classification of the space, the permit, isolation, ventilation, an attendant and rescue also apply.

Benching

A method of protecting employees from cave-ins by excavating the sides of an excavation to form one or a series of horizontal levels or steps, usually with vertical or near-vertical surfaces between levels (1926.650(b)). Benching is one of the sloping and benching systems whose slopes and configurations are selected under 1926.652(b), by one of four options: a slope not steeper than 1½H:1V (Option 1), Appendices A and B (Option 2), other tabulated data (Option 3), or a design approved by a registered professional engineer (Option 4). Appendix B to Subpart P lists benched configurations for Type A and Type B soil in excavations 20 feet or less in depth, and it lists no benched configuration for Type C soil.

Competent Person (Excavation)

In OSHA's excavation standard (Subpart P), a competent person is one who is capable of identifying existing and predictable hazards in the surroundings, or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them (1926.650(b)). The competent person inspects excavations, the adjacent areas and protective systems before the start of work, as needed throughout the shift (not a continuous watch), and after every rainstorm or other hazard increasing occurrence, when employee exposure can be reasonably anticipated (1926.651(k)(1)). Exposed employees are removed from the hazardous area when the competent person finds evidence of a possible cave-in or another hazardous condition, until the necessary precautions have been taken (1926.651(k)(2)). When Appendix A to Subpart P applies, a competent person also classifies each soil and rock deposit as stable rock, Type A, Type B or Type C, based on a visual and a manual analysis.

Confined Space

A space that is large enough and so configured that an employee can bodily enter it, has limited or restricted means for entry and exit, and is not designed for continuous employee occupancy (1926.1202). It is a permit space (also called a PRCS) if it has one or more of these characteristics: it contains or has a potential to contain a hazardous atmosphere; it contains a material that has the potential for engulfing an entrant; it has an internal configuration such that an entrant could be trapped or asphyxiated by inwardly converging walls or by a floor that slopes downward and tapers to a smaller cross-section; or it contains any other recognized serious safety or health hazard. A competent person identifies the confined spaces and the permit spaces before work begins (1926.1203(a)). An employer that decides to have employees enter a permit space has a written permit space program (1926.1203(d)), or uses the alternate procedures of 1926.1203(e) when their conditions are met, and a permit space can be reclassified as a non-permit confined space only when a competent person determines that the requirements of 1926.1203(g) are met.

Controlling Employer

Under OSHA's Multi-Employer Citation Policy (CPL 02-00-124), a controlling employer is an employer who has general supervisory authority over the worksite, including the power to correct safety and health violations itself or to have others correct them. Control can be established by contract or, in the absence of explicit contractual provisions, by the exercise of control in practice. In the policy's examples the controlling employer is a general contractor or a construction manager, and an architect or engineer is one only if the breadth of its involvement is sufficient. The policy works in two steps: first the employer's role (creating, exposing, correcting or controlling), then whether its actions were sufficient for that role. A controlling employer has a duty to exercise reasonable care to prevent and detect violations on the site, and it can be cited for another employer's violation of an OSHA standard even when none of its own employees are exposed, but only when it did not meet that duty.

Sources & verification

Checked against the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.

A related free tool

The free Trench Protective System Selector covers a task related to Sloping. Read the rule above first, then use the tool for your own workplace.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.

Your account keeps working as usual. Cancel anytime.