Chemical Compatibility

Verified vs OSHA sources · 2026-10-27

Whether two or more chemicals can be stored or used near each other without reacting dangerously, for example by releasing heat, toxic gas or fire. A safety data sheet gives incompatible materials in Section 10 and includes any incompatibilities in the storage conditions of Section 7 (Appendix D, Table D.1). Keeping incompatibles apart in storage is a recognized safety practice: Appendix A to OSHA's laboratory standard, which gives recommendations and sets no duties, advises consulting the SDS and keeping incompatibles separate during transport, storage, use and disposal (1910.1450 App A), and CDC's pool chemical guidance advises storing incompatible chemicals away from each other. What separation a given place needs depends on the products, the quantities, the containers, the manufacturer's instructions and local codes.

29 CFR 1910.1200 App D

Also known as: chemical segregation, storage compatibility

Chemical Compatibility at a glance

  • Appendix A to OSHA's laboratory standard, which gives recommendations and sets no duties, advises consulting the SDS and keeping incompatibles separate during transport, storage, use and disposal, and storing oxidizers, reducing agents and fuels separately to prevent contact in an accident (1910.1450 App A).
  • A sheet gives incompatibilities in Section 7 (storage conditions, including incompatibilities) and in Section 10 (incompatible materials, possibility of hazardous reactions). Neither is a complete list of every combination, so the products, quantities and uses are checked too.
  • Pairs that can react dangerously, depending on the products, concentrations and quantities, include acids with bases, oxidizers with flammables or organics, bleach with ammonia-containing products or with acids, and water-reactive metals with water.
  • Practical separation depends on containment, containers and distance, the manufacturer's instructions and local codes. CDC's pool chemical guidance advises storing each pool chemical separately in a dedicated location, including secondary containment, keeping chemicals in their original labeled containers, and following local or state building and fire codes.

In plain English

Which chemicals to keep apart because mixing them can be dangerous, for example bleach and ammonia-containing products, which can form chloramines. Checking the SDS and storing incompatible chemicals so that a leak from one cannot reach the other lowers the chance of fires, explosions and gas clouds.

What the rule says

“(a) Reactivity; (b) Chemical stability; (c) Possibility of hazardous reactions, including those associated with foreseeable emergencies; (d) Conditions to avoid (e.g., static discharge, shock, or vibration); (e) Incompatible materials; (f) Hazardous decomposition products.”
29 CFR 1910.1200 App D, Table D.1 (Section 10, Stability and reactivity)

In context

An industrial-hygiene, exposure-control, or program-management concept that applies across OSHA standards and workplaces.

29 CFR 1910 / 1926

Where this is written in OSHA's rules

Example

In this invented illustration, a site stores a pool chlorine product, which is an oxidizer, near a flammable product such as a fuel or a solvent-based cleaner. The SDS of each product lists, in Sections 7 and 10, what it is incompatible with, and an oxidizer next to flammables can start a fire if they come into contact. Whether a given pair is a problem depends on the actual products, so the sheets are read for the products on site, and the two are stored so that a leak from one cannot reach the other.

Why it matters

Reactions between incompatible chemicals can cause fires and toxic gas releases, for example when sodium hypochlorite bleach is mixed with an acid, which releases chlorine gas, or with an ammonia-containing compound, which forms chloramines (CDC MMWR). Checking Sections 7 and 10 and keeping incompatibles apart in storage lowers that chance. Which code or standard applies to a particular storage area, such as a fire code, the hazard communication program or a sector rule, depends on the site.

Separated vs. segregated

Putting incompatible chemicals on different shelves of the same cabinet may not be enough, because a spill can still let them mix. “Segregated” here means kept apart so that a leak from one cannot reach the other, by separate cabinets, secondary containment or distance, as the products, quantities, manufacturer instructions and local codes call for. No single distance or cabinet suits every case.

Examples of pairs that can react dangerously (depends on the products and conditions)

PairThe hazard
Acids + basesHeat and spatter from a vigorous neutralization, depending on concentration and quantity
Oxidizers + flammables/organicsFire or explosion are possible if they come into contact
Bleach + ammonia-containing productsChloramines can form (CDC MMWR)
Bleach + acidsChlorine gas is released (CDC MMWR)
Water-reactive metals + waterFlammable gas and fire are possible

Chemical Compatibility: frequently asked questions

What is Chemical Compatibility?
Whether two or more chemicals can be stored or used near each other without reacting dangerously, for example by releasing heat, toxic gas or fire. A safety data sheet gives incompatible materials in Section 10 and includes any incompatibilities in the storage conditions of Section 7 (Appendix D, Table D.1). Keeping incompatibles apart in storage is a recognized safety practice: Appendix A to OSHA's laboratory standard, which gives recommendations and sets no duties, advises consulting the SDS and keeping incompatibles separate during transport, storage, use and disposal (1910.1450 App A), and CDC's pool chemical guidance advises storing incompatible chemicals away from each other. What separation a given place needs depends on the products, the quantities, the containers, the manufacturer's instructions and local codes.
Where do I find a chemical's incompatibilities?
In Section 10 (Stability and reactivity) of its safety data sheet, which gives incompatible materials and the possibility of hazardous reactions, and in Section 7, whose storage conditions include any incompatibilities (Appendix D, Table D.1). The sheet is not a complete list of every combination, so the products and quantities on site are checked too.
What chemicals should not be stored together?
Examples of pairs that can react dangerously are acids with bases, oxidizers with flammables or organics, bleach with ammonia-containing products or with acids, and water-reactive materials with water. They are examples, not a complete list. The SDS of each product, the quantities and the manufacturer's instructions decide what to keep apart.
What's the difference between separating and segregating chemicals?
Separating puts them in different spots. Segregating keeps them apart so that a spill from one cannot reach the other, by separate cabinets, containment or distance, as the products, quantities, manufacturer instructions and local codes call for. A different shelf of the same cabinet may not be enough.

Related terms

Free tools for this

Governing OSHA standards

More General Safety terms

Arc Flash

An arc flash is the sudden release of thermal energy from an electrical arc fault, a short circuit that jumps through the air between energized parts. The arc can reach temperatures over 35,000°F (nearly four times the surface of the sun), causing severe burns, igniting clothing, and driving an explosive pressure wave known as the arc blast. OSHA has no single “arc-flash standard”. Its electrical rules apply instead: 29 CFR 1910.333 and 1910.335 for work practices and PPE, and 1910.269 for electric power work. The analysis method (arc-flash boundary, incident energy, arc-rated PPE) comes from NFPA 70E, a consensus standard that OSHA has not adopted; OSHA and employers can use it as a guide for hazard analysis and controls (OSHA interpretation 2006-11-14).

Experience Modification Rate (EMR)

A workers' compensation insurance multiplier that adjusts an employer's premium to reflect its own payroll and loss record compared with the expected experience of employers in the same classification. A mod of 1.00 leaves the premium unchanged (the unity mod). A mod above 1.00, a debit mod, raises the premium, and one below 1.00, a credit mod, lowers it. The mod multiplies the premium calculated before the modification. It's set by rating bureaus (NCCI or a state bureau) under each state's rules, not by OSHA.

Action Level

An airborne concentration of a substance, below the exposure limit, at which certain provisions of an OSHA standard begin to apply. Which provisions depend on the standard: they can include exposure assessment or monitoring, training and medical surveillance, each with its own trigger. The action level is set in each standard. For respirable crystalline silica it is 25 µg/m³ as an 8-hour TWA, half the 50 µg/m³ PEL; for lead it is 30 µg/m³ against a PEL of 50 µg/m³ (1910.1025), and for formaldehyde 0.5 ppm against a PEL of 0.75 ppm (1910.1048).

Administrative Controls

Changes to how and when work is done that reduce a worker's exposure without changing the hazard itself. NIOSH places administrative controls fourth in the hierarchy of controls, below elimination, substitution and engineering controls and above personal protective equipment, and gives examples such as work process training, job rotation, adequate rest breaks, limiting access to hazardous areas or machinery, and adjusting line speeds. Housekeeping, written procedures and signage fit the same description. The hierarchy is a preference order. What an OSHA standard calls for is in that standard's own words.

Biological Exposure Index (BEI)

An ACGIH guidance value for evaluating biological monitoring results. A BEI generally represents the level of a determinant most likely to be observed in specimens from healthy workers exposed at the TLV-TWA level. The determinant can be the chemical itself, one or more metabolites, or a characteristic, reversible biochemical change induced by the chemical, measured in a specimen such as blood, urine or exhaled breath. BEIs do not indicate a sharp distinction between hazardous and nonhazardous exposures, and they are advisory: an OSHA standard that calls for biological monitoring sets its own terms.

California Proposition 65

California's Safe Drinking Water and Toxic Enforcement Act of 1986. As OEHHA describes it, businesses give a “clear and reasonable” warning before knowingly and intentionally exposing anyone to a chemical on the state's list, unless the business can show that the anticipated exposure will not pose a significant risk of cancer or is significantly below levels observed to cause birth defects or other reproductive harm. The list has grown to approximately 900 chemicals. The warning requirement takes effect one year after a chemical is listed, and businesses with less than 10 employees and government agencies are exempt. The law also prohibits knowingly discharging listed chemicals into sources of drinking water. It is a California law, and the test is the exposure a business causes, not the presence of a listed chemical alone.

CAS Number

A numerical identifier assigned by CAS (Chemical Abstracts Service, a division of the American Chemical Society) to a substance registered in the CAS REGISTRY. CAS describes a CAS Registry Number as a unique and unambiguous identifier for a specific substance. Substances are added when they are identified in literature being indexed for the CAS Content Collection or when an entity requests a number for a novel substance. The number has up to 10 digits in three groups separated by hyphens: 2 to 7 digits, 2 digits, and one check digit (for example, 67-64-1 for acetone). CAS is the source and final authority for CAS Registry Numbers, and other resources may associate an incorrect number with a compound.

Ceiling Limit

An exposure limit that may not be exceeded at any instant during the workday. In OSHA's Z-tables it is marked with a “C” before the value. Unlike an 8-hour TWA (an average) or a 15-minute STEL, a Table Z-1 ceiling applies to a single moment; if instantaneous monitoring is not feasible, it is assessed as a 15-minute time-weighted average that may not be exceeded at any time during the working day. Table Z-2 instead uses an acceptable ceiling concentration with a separate acceptable maximum peak allowed for a limited time (1910.1000(a)(1), (b)(2)-(3)).

Sources & verification

Checked against the eCFR, OSHA.gov and the CDC. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.

A related free tool

The free Chemical Compatibility Matrix covers a task related to Chemical Compatibility. Read the rule above first, then use the tool for your own workplace.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.

Your account keeps working as usual. Cancel anytime.