Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

29 CFR 1926.1053 · Pennsylvania

Ladders (Construction) Requirements in Pennsylvania

Ladders (Construction) in Pennsylvania: 2026 penalties, who enforces 29 CFR 1926.1053, the paragraphs cited and free tools.

Verified vs OSHA sources · 2026-10-19

PennsylvaniaConstruction (29 CFR 1926)Federal OSHA Jurisdiction

In Pennsylvania, a serious violation of 29 CFR 1926.1053 (Ladders (Construction)) carries a maximum penalty of $16,550 per violation in 2026, rising to $165,514 for a willful or repeat violation. Ladders (Construction) is enforced for private construction employers by federal OSHA.

In FY2025, federal OSHA cited 29 CFR 1926.1053 104 times in Pennsylvania construction (8.4% of its construction citations there, the 4th most-cited standard there). The paragraph cited most was 1926.1053(b)(1) with 67 citations.

104

1926.1053 citations in Pennsylvania construction, FY2025

(b)(1)

paragraph cited most in Pennsylvania (67 citations)

11.9

fatal work injuries per 100,000 full-time workers in construction, Pennsylvania, 2024 (BLS)

Federal OSHA in Pennsylvania: 29 CFR 1926.1053, FY2025

Counted · 2026-09-26

104

citations of 29 CFR 1926.1053 in 87 inspections

$397,314

penalties, current amounts ($454,387 as first proposed)

8.4%

of the 1,245 federal construction citations in Pennsylvania

In FY2025, federal OSHA cited 29 CFR 1926.1053 (Ladders (Construction)) 104 times in inspections of Pennsylvania construction employers. It ranked fourth of the 79 standards cited in them. By classification: 88 serious, 3 repeat, 13 other-than-serious. Most-cited paragraphs: 1926.1053(b)(1) (67), 1926.1053(b)(4) (11), 1926.1053(b)(13) (4).

Counted by HazComFast from the U.S. Department of Labor's OSHA enforcement data (inspection and violation tables, retrieved September 26, 2026): citations issued October 1, 2024 – September 30, 2025 on federal OSHA inspections of construction employers (NAICS 23) in the state, deleted citations excluded, penalties at current amounts. OSHA's own cited-standards tool does not break federal states out; summed over every state, this count matches it within a few citations (6,778 for 1926.501, against 6,772). data.dol.gov

Ladders (Construction) in Pennsylvania: real citations and FY2025 totals

Counted · Oct 21, 2026

The latest 10 inspections in Pennsylvania with an item under 29 CFR 1926.1053 in the Department of Labor's OSHA enforcement data, every industry, newest first. Each line shows the item of that inspection with the largest current penalty under 29 CFR 1926.1053.

  • Aug 27, 2026 · JD BROTHERS CONTRACTOR, LLC in Hanover

    1926.1053(b)(1), serious, $2,837 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348903451 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 27, 2026 · AR ENTERPRISE, LLC in Mount Joy

    1926.1053(b)(1), serious, $2,270 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348796103 in the Department of Labor data; industry: Residential Building Construction.

  • Aug 20, 2026 · ROCK HOLLOW ROOFING LLC in Saint Marys

    1926.1053(b)(1), serious, $1,447 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349096842 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 12, 2026 · WILLOW VALLEY ROOFING, LLC in Williamsport

    1926.1053(b)(1), serious, $2,838 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348846726 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 5, 2026 · JJ MONROY CONSTRUCTION, INC. in Northampton

    1926.1053(b)(1), serious, $2,270 penalty; 3 items under 29 CFR 1926.1053 in this inspection, $2,270 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348905928 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Jul 31, 2026 · URUS CONSTRUCTION CORPORATION in Philadelphia

    1926.1053(a)(2), serious, $11,585 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349063131 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Jul 27, 2026 · REAM ROOFING ASSOCIATES, LLC in York

    1926.1053(b)(7), other-than-serious, $4,052 current penalty ($5,788 as first proposed). Case closed Aug 18, 2026. Recorded by federal OSHA.

    Inspection activity number 348950676 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Jul 24, 2026 · An employer in automotive repair and maintenance in Enola

    1926.1053(b)(1), other-than-serious, no penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349051680 in the Department of Labor data; industry: Automotive Repair and Maintenance.

  • Jul 24, 2026 · CRL CONSTRUCTION LLC in Pennsburg

    1926.1053(b)(1), other-than-serious, no penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349015404 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Jul 24, 2026 · BEZA'S CONTRACTOR, INC. in Hanover

    1926.1053(b)(6), serious, $4,256 penalty; 2 items under 29 CFR 1926.1053 in this inspection, $6,809 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348859828 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

FY2025 in Pennsylvania, every industry

106

citation items under 29 CFR 1926.1053 in 89 inspections

2

items at employers outside construction (104 at construction employers, NAICS 23)

2.6%

of the 4,009 items under 29 CFR 1926.1053 in the data

From Oct 1, 2024 to Sep 30, 2025, the data record 106 citation items under 29 CFR 1926.1053 at inspected sites in Pennsylvania, in 89 inspections, every industry included. Of the 141 sections of 29 CFR parts 1904, 1910 and 1926 cited in Pennsylvania that year (3,539 citation items in all), 8 drew more items than 29 CFR 1926.1053 and 1 drew as many. By classification: 90 serious, 0 willful, 3 repeat and 13 other-than-serious. All of them were recorded by federal OSHA offices. Of the 53 states, DC and territories with items under 29 CFR 1926.1053 in this data, 14 had more than Pennsylvania.

Paragraphs cited in Pennsylvania, FY2025
ParagraphItemsShare of the 106
1926.1053(b)(1)6965%
1926.1053(b)(4)1110%
1926.1053(b)(13)44%
1926.1053(b)(5)(i)44%
1926.1053(b)(16)44%

13 different paragraphs were cited in all; the table lists the 5 with the most items.

Industry groups with the most items: Foundation, Structure, and Building Exterior Contractors (90); Residential Building Construction (5); Nonresidential Building Construction (5). 92% of the 89 inspections with a recorded headcount were at sites with 1 to 10 employees (the headcount of the inspected site, not of the employer).

Quarter by quarter in Pennsylvania

Citation items under 29 CFR 1926.1053 at inspected sites in Pennsylvania, by quarter of issuance
QuarterItems
FY2025 · Oct to Dec 202421
FY2025 · Jan to Mar 202530
FY2025 · Apr to Jun 202525
FY2025 · Jul to Sep 202530
FY2026 · Oct to Dec 20259
FY2026 · Jan to Mar 202619
FY2026 · Apr to Jun 202619
FY2026 · Jul to Sep 202617

FY2026 so far: 64 citation items, against 106 in FY2025. FY2026 is still incomplete in the data extracted Oct 21, 2026: the Department of Labor adds citations with a delay.

29 CFR 1926.1053 in the states next to Pennsylvania

Since October 1, 2024, the data record 170 citation items under 29 CFR 1926.1053 in Pennsylvania; in the states next to it, Maryland 693 (393 in FY2025), Ohio 380 (237 in FY2025), New York 321 (186 in FY2025), New Jersey 227 (112 in FY2025), Delaware 49 (32 in FY2025) and West Virginia 17 (8 in FY2025). The latest there:

  • Sep 14, 2026 · BUILDERGURU CONTRACTING, INC. in Annapolis, Maryland

    1926.1053(b)(1), repeat, $4,200 penalty; 2 items under 29 CFR 1926.1053 in this inspection, $4,200 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by the Maryland State Plan office.

    Inspection activity number 349051185 in the Department of Labor data; industry: Nonresidential Building Construction.

  • Sep 9, 2026 · FLORISA HOME IMPROVEMENT, INC in Yonkers, New York

    1926.1053(b)(1), serious, $2,720 current penalty ($3,972 as first proposed). Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349133918 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Sep 8, 2026 · KGS CONSTRUCTION SERVICES, INCORPORATED in Frederick, Maryland

    1926.1053(a)(24), serious, $2,800 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by the Maryland State Plan office.

    Inspection activity number 349054346 in the Department of Labor data; industry: Nonresidential Building Construction.

From the Department of Labor's OSHA enforcement data, extracted Oct 21, 2026: deleted items left out, 29 CFR numbers only, placed in the state of the inspected site; establishment names as recorded, shown when they name a business or a public body; penalties as recorded on Oct 28, 2026, and they change when a case is settled or contested. These are not figures OSHA publishes for the state, and the live database can change them. Same data source and method as our HazCom enforcement study.

What federal OSHA is targeting in Pennsylvania

Pennsylvania has no state OSHA plan for private-sector work. Federal OSHA schedules inspections for the hazards set out in the published emphasis directives below.

Regional Emphasis Program for Fall Hazards in the Construction Industry

2023-01 (CPL 04) · Philadelphia Regional Office · effective October 1, 2023 · ends no later than September 30, 2028

“This Instruction applies to all Area Offices in Region III.”

Fall hazards are the named target across every area office in Region III, and the directive says why in its own background: the Bureau of Labor Statistics recorded 393 deaths from falls to a lower level in construction in 2021, up from 321 in 2018. The program runs to September 30, 2028.

Read the directive · verified 2026-08-09

Regional Emphasis Program for Demolition Activities and Gut Rehabilitation

2023-07 (CPL 04) · Philadelphia Regional Office · effective October 1, 2023 · ends no later than September 30, 2028

“This Instruction applies to all worksites located within the jurisdiction of the Region III, Philadelphia, Charleston, Wilkes-Barre, Erie, Allentown, Baltimore/Washington, Harrisburg, and Pittsburgh Area Offices.”

Demolition and gut rehabilitation carry their own programmed-inspection program, aimed at the destruction and renovation of fixed buildings and structures. The area offices are named individually (Philadelphia, Charleston, Wilkes-Barre, Erie, Allentown, Baltimore/Washington, Harrisburg and Pittsburgh), so the reach is Pennsylvania, West Virginia and the District through the Baltimore/Washington office.

Read the directive · verified 2026-08-09

Every emphasis program, region by region

How Pennsylvania Enforces 29 CFR 1926.1053

Pennsylvania has no State Plan, so federal OSHA has jurisdiction. 29 CFR 1926.1053 is enforced by U.S. Department of Labor compliance officers using standard federal procedures and the federal penalty maximums.

In Pennsylvania, the FY2025 citations under 29 CFR 1926.1053 went most often to Roofing Contractors (56) and Framing Contractors (25). Citing instances separately is a discretionary exception: OSHA's instance-by-instance policy of April 17, 2024 allows it for serious or repeat violations, and other-than-serious recordkeeping violations, where the standard's text allows it.

Help and oversight in Pennsylvania

Free, confidential help: OSHA On-Site Consultation

In Pennsylvania, the program is Pennsylvania OSHA Consultation. OSHA describes it as “Primarily for smaller businesses, no-cost, confidential consultations help employers identify and address hazards and establish or improve safety and health programs.” It is separate from OSHA enforcement; the employer commits to correcting serious hazards.

Pennsylvania consultation program · OSHA consultation directory

Who inspects private employers here

Federal OSHA, from the Allentown Area Office (Center Valley), the Erie Area Office (Erie), the Harrisburg Area Office (Harrisburg), the Philadelphia Area Office (Philadelphia), the Pittsburgh Area Office (Pittsburgh) and the Wilkes-Barre Area Office (Wilkes-Barre).

OSHA offices for Pennsylvania

Sources: osha.gov and the state's official statute site, September 26, 2026.

Pennsylvania Penalty Amounts for 29 CFR 1926.1053 (2026)

Reviewed · 2026-10-19

Federal amounts effective January 15, 2025 (29 CFR 1903.15(d)).

Violation type2026 maximumBasis
Serious$16,550Federal max · 29 CFR 1903.15(d)
Willful$165,514Federal max · 29 CFR 1903.15(d)
Repeat$165,514Federal max · 29 CFR 1903.15(d)
Failure to abate$16,550/dayup to $16,550 per day; the total is normally capped at 30 times the daily amount (FOM Ch.6)

Pennsylvania applies the federal OSHA maximums. Amounts are ceilings per violation. Federal OSHA can reduce the proposed penalty for employer size, good faith and history, depending on the violation class and the facts (FOM CPL 02-00-164 Ch. 6). There was no inflation increase for 2026: the 2025 amounts remain in effect (OMB Memo M-26-11).

Key Ladders (Construction) Requirements 29 CFR 1926.1053

  • Give a portable ladder used to reach an upper landing surface side rails that extend at least 3 feet above it; where the ladder's length makes that impossible, secure it at the top to a rigid support that will not deflect and provide a grasping device (1926.1053(b)(1))
  • Use ladders only on stable and level surfaces unless they are secured to prevent accidental displacement; do not use them on slippery surfaces unless secured or fitted with slip-resistant feet; secure a ladder placed where work or traffic can displace it, or barricade it (1926.1053(b)(6)-(8))
  • Place a non-self-supporting ladder at the angle the rule sets, about one-quarter of the working length from the base, except for the site-built wooden ladder cases it lists (1926.1053(b)(5))
  • Have a competent person inspect ladders for visible defects on a periodic basis and after any occurrence that could affect their safe use; mark or tag a defective portable ladder "Do Not Use" and withdraw it until repaired (1926.1053(b)(15)-(16))
  • Do not load a ladder beyond its maximum intended load (1926.1053(a)(1)) and do not use the top or top step of a stepladder as a step (1926.1053(b)(13))
  • Each employee faces the ladder when climbing, uses at least one hand to grasp it, and carries no object or load that could cause a loss of balance (1926.1053(b)(20)-(22))

Who enforces it in Pennsylvania: Federal OSHA inspects private construction employers; Pennsylvania has no State Plan.

The compliance checklist, the paragraphs OSHA cites nationally and what an inspector checks under 29 CFR 1926.1053 are on the 29 CFR 1926.1053 page.

Most-Cited Ladders (Construction) Paragraphs in Pennsylvania, FY2025

Federal OSHA issued 104 citations under 29 CFR 1926.1053 to Pennsylvania construction employers in FY2025. The paragraphs cited most, with the official text. A serious violation carries up to $16,550.

  • 1

    1926.1053(b)(1) 67 citations

    “When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing …”

  • 2

    1926.1053(b)(4) 11 citations

    “Ladders shall be used only for the purpose for which they were designed.”

  • 3

    1926.1053(b)(13) 4 citations

    “The top or top step of a stepladder shall not be used as a step.”

  • 4

    1926.1053(b)(16) 4 citations

    “Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or …”

  • 5

    1926.1053(b)(5)(i) 4 citations

    “Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the …”

  • 6

    1926.1053(b)(6) 3 citations

    “Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.”

HazComFast count from the Labor Department's OSHA enforcement data: citations issued in FY2025 to construction employers (NAICS 23), by the paragraph cited. Paragraph text: eCFR, current as of September 24, 2026. data.dol.gov

Pennsylvania Safety & Enforcement Profile

26,559

Federal construction citations (national, FY2025)
1,245 of them in Pennsylvania (HazComFast count)

Federal OSHA

Enforces private construction

  • Construction trades inspected most in Pennsylvania, FY2025: Commercial and Institutional Building Construction (281), Roofing Contractors (257) and Framing Contractors (95), out of 1,354 inspections opened (federal OSHA and State Plan combined).
  • Cited most under 29 CFR 1926.1053 in Pennsylvania, FY2025: Roofing Contractors (56), Framing Contractors (25) and Siding Contractors (5), of 104 citations.
  • Construction fatality rate in Pennsylvania, 2024: 11.9 per 100,000 full-time workers, 10th highest of the 40 states BLS published (all industries: 3.1).

HazComFast count from the Labor Department's OSHA enforcement data: inspections of construction employers (NAICS 23) opened from October 1, 2024 to September 30, 2025, federal OSHA and State Plan combined, grouped by the inspected employer's 2022 NAICS industry. HazComFast count from the Labor Department's OSHA enforcement data: citations issued in FY2025 to construction employers (NAICS 23), grouped by the cited employer's 2022 NAICS industry. Industry names are the Census Bureau's 2022 NAICS titles. data.dol.gov · BLS fatality rates by state, 2024

Free Ladders (Construction) Compliance Tools

Ladders (Construction) FAQ for Pennsylvania

Which Pennsylvania construction trades are cited most under Ladders (Construction)?

In FY2025, federal OSHA issued 104 citations under 29 CFR 1926.1053 to Pennsylvania construction employers, most often to Roofing Contractors (56), Framing Contractors (25) and Siding Contractors (5) (HazComFast count from Labor Department enforcement data, by the cited employer's NAICS industry). Federal OSHA inspects these employers directly, since Pennsylvania has no state plan covering the private sector. For context, federal OSHA issued 1,245 citations across 546 inspections of Pennsylvania construction employers in FY2025 (HazComFast count from Labor Department enforcement data). On a jobsite, the standard on this subject is 29 CFR 1926.1053.

How often is Ladders (Construction) cited on Pennsylvania jobsites?

OSHA's cited-standards tool does not break Pennsylvania out, but the Labor Department's enforcement data do: in FY2025, federal OSHA issued 1,245 citations across 546 inspections of Pennsylvania construction employers, 104 of them under 29 CFR 1926.1053 (HazComFast count). Pennsylvania's fatality figures are shown above.

Who enforces ladder rules (1926.1053) on Pennsylvania construction sites?

Federal OSHA. Pennsylvania has no State Plan, so a compliance officer from OSHA's Philadelphia region inspects and cites 29 CFR 1926.1053 directly at the federal penalty maximums.

Can I get free OSHA help in Pennsylvania without an inspection?

Yes. OSHA's On-Site Consultation Program in Pennsylvania is Pennsylvania OSHA Consultation. OSHA describes it this way: "Primarily for smaller businesses, no-cost, confidential consultations help employers identify and address hazards and establish or improve safety and health programs." Consultations are separate from OSHA enforcement, and the employer commits to correcting serious hazards.

How often does federal OSHA cite 29 CFR 1926.1053 in Pennsylvania construction?

In FY2025, federal OSHA cited 29 CFR 1926.1053 (Ladders (Construction)) 104 times in 87 inspections of Pennsylvania construction employers, with $397,314 in penalties at current amounts ($454,387 as first proposed), 8.4% of the 1,245 citations those inspections produced. It ranked fourth of the 79 standards cited. (HazComFast count from U.S. Department of Labor OSHA enforcement data, retrieved 2026-09-26.)

Want the complete federal guide for this standard?

Compare this combination against any other state and standard with the enforcement risk lookup.

Sources & verification

Penalty amounts and plan-type data were checked on 2026-10-19 against eCFR, OSHA.gov, and the Federal Register. This page is informational and not legal advice; consult the enforcing agency or counsel for your specific situation.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.