Skip to content

Approaching: Nov 20, 2026 — HCS 2024 Deadline. Get ready →

Safety Data Sheet term · Glossary

Section 5: Fire-Fighting Measures

Verified vs OSHA sources · 2026-10-05

The SDS section written for anyone fighting a fire involving the chemical. It lists suitable and unsuitable extinguishing media, the specific hazards the chemical creates in a fire (toxic combustion products, explosion risk, reactivity), and the special protective equipment and precautions firefighters need. It's a key reference for the fire department's pre-planning.

29 CFR 1910.1200 App D

Also known as: SDS Section 5, firefighting section

Section 5: Fire-Fighting Measures at a glance

  • Lists suitable AND unsuitable extinguishing media (e.g., “do not use water”).
  • Describes hazardous combustion products (toxic gases, smoke).
  • Notes explosion or reactivity risks during a fire.
  • Specifies special firefighter PPE (often SCBA and full protective gear).

In plain English

The “how to fight a fire with this stuff” page. It says what to put the fire out with (and what NOT to use — water can make some fires worse), what nasty gases it gives off when burning, and what gear firefighters need.

What the source says, in summary

Section 5, Fire-fighting measures: suitable (and unsuitable) extinguishing media; specific hazards arising from the chemical (e.g., nature of any hazardous combustion products); and special protective equipment and precautions for fire-fighters.
29 CFR 1910.1200 App D (Section 5)Summarized, not quoted: read the source for its operative wording.

In context

A concept tied to the 16-section Safety Data Sheet required for every hazardous chemical under OSHA's Hazard Communication Standard, 29 CFR 1910.1200(g).

29 CFR 1910.1200(g)

Where this is written in OSHA's rules

Example

For a water-reactive metal, Section 5 warns “Do NOT use water” (it can intensify the fire or release flammable gas), recommends a dry-powder extinguisher, notes toxic fumes on combustion, and calls for SCBA — exactly what a responding firefighter needs to know before acting.

Why it matters

Using the wrong extinguishing medium can turn a small fire into an explosion — water on a metal fire or a live electrical fire being the classic example. Section 5 is what the fire department relies on for pre-incident planning, so an incomplete or wrong Section 5 endangers responders.

Suitable vs. unsuitable extinguishing media

Section 5 lists both on purpose. “Suitable” is what to use; “unsuitable” is what will make things worse (for example, water on a water-reactive or burning-metal fire). Reading only the “suitable” line and ignoring the “unsuitable” warning is a dangerous mistake.

What Section 5 covers

ElementWhat it tells responders
Suitable extinguishing mediaWhat to use to put the fire out
Unsuitable extinguishing mediaWhat NOT to use (e.g., water)
Specific hazardsToxic combustion products, explosion risk
Firefighter PPESpecial protective equipment (e.g., SCBA)

Section 5: Fire-Fighting Measures: frequently asked questions

What is in Section 5 of an SDS?
Suitable and unsuitable extinguishing media, the specific hazards the chemical creates in a fire (such as toxic combustion products), and the special protective equipment and precautions for firefighters.
Why does Section 5 list 'unsuitable' extinguishing media?
Because the wrong medium can make a fire worse — for example, water on a water-reactive substance or a burning metal. Section 5 warns responders what not to use.
Who uses Section 5?
Emergency responders and fire departments — often during pre-incident planning — as well as on-site emergency teams deciding how to respond to a fire involving the chemical.

Related terms

Free tools for this

Governing OSHA standards

More SDS terms

Safety Data Sheet (SDS)

A standardized 16-section document the chemical manufacturer, importer, or distributor must provide for every hazardous chemical, detailing its hazards, safe handling, storage, exposure controls, first aid, and emergency information. Its content and order are set by 29 CFR 1910.1200(g) and Appendix D; it replaced the unstandardized MSDS under GHS alignment.

Readily Accessible

The OSHA requirement that safety data sheets be readily accessible to employees during each work shift, in their work areas (29 CFR 1910.1200(g)(8); adopted for construction by 1926.59). “Readily accessible” means without barriers or unreasonable delay — electronic access is allowed, but only with reliable backup for power or system failures and no obstacle between the worker and the SDS.

Section 1: Identification

The first section of a Safety Data Sheet. It identifies the chemical and who's responsible for it: the product identifier (matching the label), recommended use and restrictions, the manufacturer/importer's name, address, and phone, and — critically — an emergency phone number. It's the section a responder reads first to confirm they have the right SDS.

Section 2: Hazard Identification

The SDS section that states what's dangerous about the chemical: its GHS hazard classification (each hazard class and category), all the required label elements (pictograms, signal word, hazard statements, precautionary statements), and any hazards not otherwise classified (HNOC). It's the fastest read for “how could this hurt me?”

Section 3: Composition / Information on Ingredients

The SDS section that discloses what the chemical is made of: the chemical name, common names/synonyms, CAS number, and concentration (or concentration range) of the substance or of each hazardous ingredient in a mixture. Any ingredient that contributes to a classified hazard must be listed, subject to limited trade-secret protection.

Section 4: First-Aid Measures

The SDS section that tells you what to do if someone is exposed. It gives first-aid instructions broken out by route of exposure — inhalation, skin, eye, and ingestion — plus the most important symptoms (immediate and delayed) and any indication of the need for immediate medical attention or special treatment. It's the section to open in a medical emergency.

Section 6: Accidental Release Measures

The SDS section that tells you how to handle a spill or leak. It covers personal precautions, protective equipment, and emergency procedures (protecting people first), environmental precautions (keeping it out of drains and waterways), and the methods and materials for containment and cleanup. It's the spill-response playbook for the chemical.

Section 7: Handling & Storage

The SDS section on how to work with and store the chemical safely day to day. It covers precautions for safe handling (hygiene practices, avoiding ignition sources or incompatible conditions) and conditions for safe storage — temperature, ventilation, container type, and, importantly, which materials it must be kept away from (incompatibilities).

Sources & verification

Reviewed by HazComFast against eCFR, OSHA.gov, NIOSH, and the Federal Register. Last reviewed 2026-10-05. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.

Put Section 5: Fire-Fighting Measures into practice

Don't just read the definition — apply it. Use the free SDS Gap Analyzer to put real numbers behind Section 5: Fire-Fighting Measures for your jobsite.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA does not give advance notice of inspections (29 CFR 1903.6). Get the binder in order before the opening conference, not during it.