Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

Safety Data Sheet term · Glossary

Section 1: Identification

Verified vs OSHA sources · 2026-10-27

The first section of a Safety Data Sheet, with the minimum information of 29 CFR 1910.1200 Appendix D, Table D.1: (a) the product identifier used on the label, (b) other means of identification, (c) the recommended use of the chemical and restrictions on use, (d) the name, U.S. address and U.S. telephone number of the chemical manufacturer, importer or other responsible party, and (e) an emergency phone number. It is where a reader confirms that the SDS belongs to the container in front of them and finds who to contact.

29 CFR 1910.1200 App D29 CFR 1910.1200 Appendix D

Also known as: SDS Section 1, identification section

Section 1: Identification at a glance

  • The product identifier is the one used on the label (Table D.1, Section 1(a)), and the label carries the product identifier used on the SDS (Appendix C, C.1). OSHA's letter of June 19, 2015 reads that as matching word for word.
  • Section 1 also lists other means of identification and the recommended use of the chemical and restrictions on use (1(b), 1(c)).
  • The responsible party's entry is the name, U.S. address and U.S. telephone number of the chemical manufacturer, importer or other responsible party (1(d)).
  • Section 1 includes an emergency phone number (1(e)). Appendix D does not set hours for it; OSHA's letter of October 25, 1986, written about an earlier version of the standard, says each manufacturer decides the hours of its emergency line.

In plain English

The “who and what” page of the SDS: the label's product identifier, recommended use, U.S. contact details and an emergency number. It is how you confirm the SDS matches the container in front of you.

What the rule says

“(a) Product identifier used on the label; (b) Other means of identification; (c) Recommended use of the chemical and restrictions on use; (d) Name, U.S. address, and U.S. telephone number of the chemical manufacturer, importer, or other responsible party; (e) Emergency phone number.”
29 CFR 1910.1200 App D, Table D.1 (Section 1, Identification)

In context

A concept tied to the 16-section Safety Data Sheet required for every hazardous chemical under OSHA's Hazard Communication Standard, 29 CFR 1910.1200(g).

29 CFR 1910.1200(g)

Where this is written in OSHA's rules

Example

For a drum of acetone, Section 1 shows the product identifier used on the label, a recommended use such as “solvent,” the name, U.S. address and U.S. telephone number of the responsible party, and an emergency phone number. A responder uses the identifier to confirm that the SDS matches the labeled drum before acting.

Why it matters

Section 1 is where a reader checks that the SDS matches the chemical and finds who to contact. An identifier that does not match the label, or a missing U.S. contact or emergency number, leaves Section 1 short of what Table D.1 lists, and the SDS falls short of 1910.1200(g)(2) and Appendix D.

Section 1 identifier vs. the label

Section 1 lists the product identifier used on the label (Appendix D, Section 1(a)), and the label carries the product identifier used on the SDS (Appendix C, C.1), so the two can be cross-referenced (1910.1200(c)). Under OSHA's letter of June 19, 2015, the product identifier matches word for word, while product codes added only as supplemental information can differ if cross-referencing still works.

What Section 1 lists (Appendix D, Table D.1)

ItemContentPurpose
1(a)Product identifier used on the labelMatch the SDS to the label
1(b)Other means of identificationOther ways the chemical is identified
1(c)Recommended use of the chemical and restrictions on useHow it is meant to be used, and what it is not meant for
1(d)Name, U.S. address and U.S. telephone number of the chemical manufacturer, importer or other responsible partyWho to contact about the SDS
1(e)Emergency phone numberWho to call in an incident

Section 1: Identification: frequently asked questions

What is Section 1: Identification?
The first section of a Safety Data Sheet, with the minimum information of 29 CFR 1910.1200 Appendix D, Table D.1: (a) the product identifier used on the label, (b) other means of identification, (c) the recommended use of the chemical and restrictions on use, (d) the name, U.S. address and U.S. telephone number of the chemical manufacturer, importer or other responsible party, and (e) an emergency phone number. It is where a reader confirms that the SDS belongs to the container in front of them and finds who to contact.
What information is in Section 1 of an SDS?
The product identifier used on the label, other means of identification, the recommended use of the chemical and restrictions on use, the name, U.S. address and U.S. telephone number of the chemical manufacturer, importer or other responsible party, and an emergency phone number (Appendix D, Table D.1).
Why does the Section 1 identifier match the label?
Table D.1 lists the product identifier used on the label, and Appendix C has the label carry the product identifier used on the SDS, so a worker or responder can cross-reference the two (1910.1200(c)). If the identifiers differ, they cannot confirm that the SDS applies to the chemical they are dealing with.
Does Section 1 need an emergency phone number?
Yes. Table D.1, Section 1(e) lists an emergency phone number. Appendix D does not set hours for it. OSHA's letter of October 25, 1986, written about an earlier version of the standard, says the standard does not specify hours of operation for emergency information lines and that each chemical manufacturer decides, weighing the completeness of its sheets, the hazards of the chemicals, how often they are used and other sources of information.
Who is the 'responsible party' in Section 1?
Table D.1, Section 1(d) names the chemical manufacturer, importer or other responsible party, not only the maker of the product, and the address and telephone number are U.S. ones.

Related terms

Free tools for this

Governing OSHA standards

More SDS terms

Safety Data Sheet (SDS)

A standardized document that a chemical manufacturer or importer obtains or develops for each hazardous chemical it produces or imports, and that each employer keeps in the workplace for each hazardous chemical it uses (29 CFR 1910.1200(g)(1)). It is in English and has the 16 headings of 1910.1200(g)(2) in the order listed, with the information of Appendix D under each heading; Appendix D does not set an order for the information within a section. Distributors pass SDSs and their updates to other distributors and employers (1910.1200(g)(7)). It replaced the unstandardized Material Safety Data Sheet (MSDS) when the standard aligned with the GHS.

Readily Accessible

The employer's duty under 29 CFR 1910.1200(g)(8), adopted for construction by 1926.59, to maintain in the workplace copies of the safety data sheets for each hazardous chemical and to ensure that they are readily accessible during each work shift to employees when they are in their work area(s). Electronic access and other alternatives to paper copies are permitted as long as no barriers to immediate employee access in each workplace are created by such options. OSHA reads “readily accessible” as immediate access (letter of February 18, 1999). Where employees travel between workplaces during a workshift, the SDSs may be kept at the primary workplace facility if the employer ensures that employees can immediately obtain the information in an emergency (1910.1200(g)(9)).

Section 2: Hazard Identification

The SDS section that identifies the hazards of the chemical. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 2 gives (a) the classification of the chemical under 1910.1200(d)(1), except classification under (d)(1)(ii); (b) the signal word, hazard statement(s), symbol(s) and precautionary statement(s) in accordance with paragraph (f); (c) hazards classified under (d)(1)(ii), which are chemical reaction products associated with known or reasonably anticipated uses or applications; (d) a description of any hazards not otherwise classified (HNOC) identified during the classification process; and (e) in the case described, a statement that X% of a mixture consists of ingredient(s) of unknown acute toxicity.

Section 3: Composition / Information on Ingredients

The SDS section that discloses what the chemical is made of: the chemical name, common names/synonyms, CAS number, and, for a mixture, the exact percentage of each listed ingredient by default. A concentration range is allowed only where a trade-secret claim meets 1910.1200(i) (and then one of the prescribed ranges), where the mixture varies from batch to batch, or for a group of substantially similar mixtures. The ingredients to list are those classified as health hazards that are present above their cut-off/concentration limits or that present a health risk below the cut-off, with the unique identifier or its source where there is no CAS number, and the trade-secret statement where the specific chemical identity is withheld.

Section 4: First-Aid Measures

The SDS section with the first-aid information for the product. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 4 gives (a) a description of necessary measures, subdivided according to the different routes of exposure: inhalation, skin and eye contact, and ingestion; (b) the most important symptoms and effects, acute and delayed; and (c) an indication of immediate medical attention and special treatment needed, if necessary. It is the product reference for the first-aid steps. It does not replace calling emergency services or a poison center, and Section 1 gives the emergency phone number.

Section 5: Fire-Fighting Measures

The SDS section with the fire-fighting information for the product. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 5 gives (a) suitable (and unsuitable) extinguishing media, (b) specific hazards arising from the chemical, for example the nature of any hazardous combustion products, and (c) special protective equipment and precautions for fire-fighters. It informs the people who respond to a fire involving the chemical. Who in a workplace may fight a fire is decided by the employer's emergency action plan and 1910.157, not by the SDS.

Section 6: Accidental Release Measures

The SDS section with the spill and leak information for the product. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 6 gives (a) personal precautions, protective equipment and emergency procedures, and (b) methods and materials for containment and cleaning up. Many sheets also add environmental precautions, such as keeping the product out of drains and waterways, which Table D.1 does not list as a sub-item. The section informs the response to a release. How a release is handled in a workplace depends on its size and on the employer's plans: 1910.120 separates the response to an incidental release that employees in the immediate release area can absorb, neutralize or otherwise control from an emergency response to an uncontrolled release (1910.120(a)(3), (q)).

Section 7: Handling & Storage

The SDS section with the handling and storage information for the product. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 7 gives (a) precautions for safe handling and (b) conditions for safe storage, including any incompatibilities. The conditions depend on the product: Table D.1 does not set a temperature, a ventilation arrangement or a container for every chemical, and where no relevant information is found for a sub-heading the sheet indicates that no applicable information is available (1910.1200(g)(3)).

Sources & verification

Checked against the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.

A related free tool

The free SDS Gap Analyzer covers a task related to Section 1: Identification. Read the rule above first, then use the tool for your own workplace.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.