Safety Data Sheet term · Glossary
Section 16: Other Information
Verified vs OSHA sources · 2026-10-05
The final SDS section. It holds the housekeeping and traceability information: the date the SDS was prepared or last revised, an indication of what changed from the previous version, a key to any abbreviations and acronyms used, and the references or data sources. Unlike sections 12–15, Section 16 is OSHA-enforced.
Also known as: SDS Section 16, other information section
On this page
Section 16: Other Information at a glance
- Contains the date of preparation or last revision — the currency check.
- Indicates what changed from the previous version.
- Provides a key to abbreviations/acronyms and the references used.
- Unlike sections 12–15, Section 16 IS enforced by OSHA.
In plain English
The “version and notes” page — the last one. It tells you when the SDS was written or last updated, what changed, what the abbreviations mean, and where the data came from. The revision date here is how you know if an SDS is current.
What the source says, in summary
Section 16, Other information, including date of preparation or last revision.
In context
A concept tied to the 16-section Safety Data Sheet required for every hazardous chemical under OSHA's Hazard Communication Standard, 29 CFR 1910.1200(g).
Where this is written in OSHA's rules
- 29 CFR 1910.1200 App DRead on eCFR / OSHA.gov
Example
Section 16 shows “Revision date: 2026-03-10, replaces 2023-06-01,” notes that Section 2 classifications were updated for the 2024 HCS, defines abbreviations like STEL and PBT, and lists the data sources — letting a reviewer confirm the SDS is current.
Why it matters
Section 16's revision date is how you audit an SDS library for currency — an SDS that hasn't been updated after a classification change (like the 2024 HCS) is a compliance gap. Because Section 16 is OSHA-enforced, a missing or blank revision date is a citable SDS deficiency under 1910.1200(g).
Section 16 is enforced; 12–15 are not
It's easy to assume the last four sections (12–15–16) are all “not OSHA's business.” In fact, OSHA does not enforce the content of sections 12–15 (ecological, disposal, transport, regulatory) but DOES enforce Section 16 — largely because the revision date and change history it carries are essential for keeping SDSs current.
What Section 16 contains
| Element | Purpose |
|---|---|
| Date of preparation / last revision | Confirm the SDS is current |
| Changes from previous version | Show what was updated |
| Abbreviations & acronyms key | Decode terms used on the sheet |
| References / data sources | Trace where the information came from |
Section 16: Other Information: frequently asked questions
- What is in Section 16 of an SDS?
- Other information for traceability: the date of preparation or last revision, an indication of what changed, a key to abbreviations and acronyms, and the references or data sources used.
- How do I tell if an SDS is current?
- Check the revision date in Section 16. If it predates a relevant classification change (such as the 2024 HCS update), the SDS may be outdated and should be refreshed.
- Does OSHA enforce Section 16?
- Yes. Unlike sections 12–15, Section 16 is within OSHA's enforcement — its revision date and change history are part of keeping an SDS accurate and current.
Related terms
Free tools for this
Governing OSHA standards
More SDS terms
A standardized 16-section document the chemical manufacturer, importer, or distributor must provide for every hazardous chemical, detailing its hazards, safe handling, storage, exposure controls, first aid, and emergency information. Its content and order are set by 29 CFR 1910.1200(g) and Appendix D; it replaced the unstandardized MSDS under GHS alignment.
Readily AccessibleThe OSHA requirement that safety data sheets be readily accessible to employees during each work shift, in their work areas (29 CFR 1910.1200(g)(8); adopted for construction by 1926.59). “Readily accessible” means without barriers or unreasonable delay — electronic access is allowed, but only with reliable backup for power or system failures and no obstacle between the worker and the SDS.
Section 1: IdentificationThe first section of a Safety Data Sheet. It identifies the chemical and who's responsible for it: the product identifier (matching the label), recommended use and restrictions, the manufacturer/importer's name, address, and phone, and — critically — an emergency phone number. It's the section a responder reads first to confirm they have the right SDS.
Section 2: Hazard IdentificationThe SDS section that states what's dangerous about the chemical: its GHS hazard classification (each hazard class and category), all the required label elements (pictograms, signal word, hazard statements, precautionary statements), and any hazards not otherwise classified (HNOC). It's the fastest read for “how could this hurt me?”
Section 3: Composition / Information on IngredientsThe SDS section that discloses what the chemical is made of: the chemical name, common names/synonyms, CAS number, and concentration (or concentration range) of the substance or of each hazardous ingredient in a mixture. Any ingredient that contributes to a classified hazard must be listed, subject to limited trade-secret protection.
Section 4: First-Aid MeasuresThe SDS section that tells you what to do if someone is exposed. It gives first-aid instructions broken out by route of exposure — inhalation, skin, eye, and ingestion — plus the most important symptoms (immediate and delayed) and any indication of the need for immediate medical attention or special treatment. It's the section to open in a medical emergency.
Section 5: Fire-Fighting MeasuresThe SDS section written for anyone fighting a fire involving the chemical. It lists suitable and unsuitable extinguishing media, the specific hazards the chemical creates in a fire (toxic combustion products, explosion risk, reactivity), and the special protective equipment and precautions firefighters need. It's a key reference for the fire department's pre-planning.
Section 6: Accidental Release MeasuresThe SDS section that tells you how to handle a spill or leak. It covers personal precautions, protective equipment, and emergency procedures (protecting people first), environmental precautions (keeping it out of drains and waterways), and the methods and materials for containment and cleanup. It's the spill-response playbook for the chemical.
Sources & verification
- 29 CFR 1910.1200 App D (eCFR / OSHA.gov)
- OSHA — Appendix D to §1910.1200: Safety Data Sheets
- OSHA Brief — Safety Data Sheets (OSHA 3514)
Reviewed by HazComFast against eCFR, OSHA.gov, NIOSH, and the Federal Register. Last reviewed 2026-10-05. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
Put Section 16: Other Information into practice
Don't just read the definition — apply it. Use the free SDS Gap Analyzer to put real numbers behind Section 16: Other Information for your jobsite.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA does not give advance notice of inspections (29 CFR 1903.6). Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.