Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

Safety Data Sheet term · Glossary

Section 12: Ecological Information

Verified vs OSHA sources · 2026-10-27

The SDS section with the ecological information for the product. Under 29 CFR 1910.1200(g)(2), the SDS includes the headings of Sections 12 to 15 in order (Note 1), and OSHA will not enforce the information requirements in Sections 12 to 15, as these areas are not under its jurisdiction (Note 2). Appendix D lists the Section 12 items as non-mandatory: (a) ecotoxicity (aquatic and terrestrial, where available), (b) persistence and degradability, (c) bioaccumulative potential, (d) mobility in soil, and (e) other adverse effects, such as hazardous to the ozone layer. The same information can matter under other agencies' rules.

29 CFR 1910.1200 App D29 CFR 1910.1200(g)(2)

Also known as: SDS Section 12, ecological information section

Section 12: Ecological Information at a glance

  • Table D.1, Section 12 (content that Appendix D says may be included): ecotoxicity (aquatic and terrestrial, where available); persistence and degradability; bioaccumulative potential; mobility in soil; other adverse effects.
  • Heading and content are separate questions. Note 1 to 1910.1200(g)(2) says the SDS includes the headings of Sections 12 to 15 in order. Note 2 says OSHA will not enforce the information requirements in Sections 12 to 15, as these areas are not under its jurisdiction. Appendix D says the content of these sections may be included but is not mandatory.
  • GHS09, the environment pictogram, is not one of the eight pictograms of OSHA's Appendix C (see GHS09). Section 12 data can relate to aquatic toxicity in other systems, but the label elements under OSHA's standard are those of Appendix C.
  • Other agencies have their own tests. A release notification under CERCLA depends on a hazardous substance and a quantity equal to or exceeding the reportable quantity (40 CFR 302.6), and a waste determination under RCRA is made by the person who generates the waste, on the waste, at the point of generation (40 CFR 262.11). Section 12 is the test for neither.

In plain English

The “what it does to the environment” page of the SDS: ecotoxicity, persistence, bioaccumulation and mobility in soil. OSHA does not enforce its content. The heading stays on the sheet, and other agencies' rules can use the information.

What the source says, in summary

Section 12, Ecological information (non-mandatory): ecotoxicity (aquatic and terrestrial, where available); persistence and degradability; bioaccumulative potential; mobility in soil; and other adverse effects.
29 CFR 1910.1200 App D (Section 12, non-mandatory)Summarized, not quoted: read the source for its operative wording.

In context

A concept tied to the 16-section Safety Data Sheet required for every hazardous chemical under OSHA's Hazard Communication Standard, 29 CFR 1910.1200(g).

29 CFR 1910.1200(g)

Where this is written in OSHA's rules

Example

In this invented illustration, a product's Section 12 reports aquatic toxicity, persistence, bioaccumulative potential and soil mobility data for that product. The data can inform storage, disposal and spill planning. They do not by themselves decide labeling under OSHA's standard, which uses the classes and elements of Appendices A, B and C, or reporting and waste obligations, which other agencies' rules decide.

Why it matters

OSHA does not enforce the information in Section 12, but the information can be useful for decisions made under other rules, such as spill planning and waste management. Those rules have their own tests: CERCLA release notification depends on the substance and the quantity (40 CFR 302.6), and the RCRA hazardous waste determination is made on the waste at the point of generation (40 CFR 262.11). Section 12 informs those assessments and does not replace them. Ignoring the section because OSHA does not check it can leave out information they use.

“Not OSHA-enforced” doesn't mean “unregulated”

Sections 12 to 15 (ecological, disposal, transport, regulatory) are not under OSHA's jurisdiction, so OSHA does not enforce their information requirements (Note 2 to 1910.1200(g)(2)). The SDS still includes their headings in order (Note 1), while Appendix D lists their content as non-mandatory. That is not the same as unregulated: the hazards they describe are governed by other agencies, for example the EPA and DOT. The heading and the content are separate questions.

What Section 12 covers (Appendix D, Table D.1; content that may be included)

ItemWhat it describes
12(a) EcotoxicityAquatic and terrestrial, where available
12(b) Persistence and degradabilityHow long it lasts in the environment and whether it degrades
12(c) Bioaccumulative potentialWhether it builds up in organisms
12(d) Mobility in soilHow readily it moves through soil
12(e) Other adverse effectsSuch as hazardous to the ozone layer

Section 12: Ecological Information: frequently asked questions

What is Section 12: Ecological Information?
The SDS section with the ecological information for the product. Under 29 CFR 1910.1200(g)(2), the SDS includes the headings of Sections 12 to 15 in order (Note 1), and OSHA will not enforce the information requirements in Sections 12 to 15, as these areas are not under its jurisdiction (Note 2). Appendix D lists the Section 12 items as non-mandatory: (a) ecotoxicity (aquatic and terrestrial, where available), (b) persistence and degradability, (c) bioaccumulative potential, (d) mobility in soil, and (e) other adverse effects, such as hazardous to the ozone layer. The same information can matter under other agencies' rules.
What is in Section 12 of an SDS?
Ecotoxicity (aquatic and terrestrial, where available), persistence and degradability, bioaccumulative potential, mobility in soil, and other adverse effects (Appendix D, Table D.1; content that may be included).
Does an SDS still carry Section 12 if OSHA doesn't enforce it?
The heading, yes. Note 1 to 1910.1200(g)(2) says the SDS includes the headings of Sections 12 to 15 in order, Note 2 says OSHA will not enforce the information requirements in those sections because they are not under its jurisdiction, and Appendix D says the content may be included but is not mandatory. Whether a sheet fills the section is the preparer's choice under OSHA's standard, and other rules can call for the information.
Which SDS sections does OSHA enforce?
Appendix D sets the information of Sections 1 to 11 and 16 as the minimum content of an SDS. OSHA does not enforce the information requirements in Sections 12 to 15 (Note 2 to 1910.1200(g)(2)).

Related terms

Free tools for this

Governing OSHA standards

More SDS terms

Safety Data Sheet (SDS)

A standardized document that a chemical manufacturer or importer obtains or develops for each hazardous chemical it produces or imports, and that each employer keeps in the workplace for each hazardous chemical it uses (29 CFR 1910.1200(g)(1)). It is in English and has the 16 headings of 1910.1200(g)(2) in the order listed, with the information of Appendix D under each heading; Appendix D does not set an order for the information within a section. Distributors pass SDSs and their updates to other distributors and employers (1910.1200(g)(7)). It replaced the unstandardized Material Safety Data Sheet (MSDS) when the standard aligned with the GHS.

Readily Accessible

The employer's duty under 29 CFR 1910.1200(g)(8), adopted for construction by 1926.59, to maintain in the workplace copies of the safety data sheets for each hazardous chemical and to ensure that they are readily accessible during each work shift to employees when they are in their work area(s). Electronic access and other alternatives to paper copies are permitted as long as no barriers to immediate employee access in each workplace are created by such options. OSHA reads “readily accessible” as immediate access (letter of February 18, 1999). Where employees travel between workplaces during a workshift, the SDSs may be kept at the primary workplace facility if the employer ensures that employees can immediately obtain the information in an emergency (1910.1200(g)(9)).

Section 1: Identification

The first section of a Safety Data Sheet, with the minimum information of 29 CFR 1910.1200 Appendix D, Table D.1: (a) the product identifier used on the label, (b) other means of identification, (c) the recommended use of the chemical and restrictions on use, (d) the name, U.S. address and U.S. telephone number of the chemical manufacturer, importer or other responsible party, and (e) an emergency phone number. It is where a reader confirms that the SDS belongs to the container in front of them and finds who to contact.

Section 2: Hazard Identification

The SDS section that identifies the hazards of the chemical. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 2 gives (a) the classification of the chemical under 1910.1200(d)(1), except classification under (d)(1)(ii); (b) the signal word, hazard statement(s), symbol(s) and precautionary statement(s) in accordance with paragraph (f); (c) hazards classified under (d)(1)(ii), which are chemical reaction products associated with known or reasonably anticipated uses or applications; (d) a description of any hazards not otherwise classified (HNOC) identified during the classification process; and (e) in the case described, a statement that X% of a mixture consists of ingredient(s) of unknown acute toxicity.

Section 3: Composition / Information on Ingredients

The SDS section that discloses what the chemical is made of: the chemical name, common names/synonyms, CAS number, and, for a mixture, the exact percentage of each listed ingredient by default. A concentration range is allowed only where a trade-secret claim meets 1910.1200(i) (and then one of the prescribed ranges), where the mixture varies from batch to batch, or for a group of substantially similar mixtures. The ingredients to list are those classified as health hazards that are present above their cut-off/concentration limits or that present a health risk below the cut-off, with the unique identifier or its source where there is no CAS number, and the trade-secret statement where the specific chemical identity is withheld.

Section 4: First-Aid Measures

The SDS section with the first-aid information for the product. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 4 gives (a) a description of necessary measures, subdivided according to the different routes of exposure: inhalation, skin and eye contact, and ingestion; (b) the most important symptoms and effects, acute and delayed; and (c) an indication of immediate medical attention and special treatment needed, if necessary. It is the product reference for the first-aid steps. It does not replace calling emergency services or a poison center, and Section 1 gives the emergency phone number.

Section 5: Fire-Fighting Measures

The SDS section with the fire-fighting information for the product. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 5 gives (a) suitable (and unsuitable) extinguishing media, (b) specific hazards arising from the chemical, for example the nature of any hazardous combustion products, and (c) special protective equipment and precautions for fire-fighters. It informs the people who respond to a fire involving the chemical. Who in a workplace may fight a fire is decided by the employer's emergency action plan and 1910.157, not by the SDS.

Section 6: Accidental Release Measures

The SDS section with the spill and leak information for the product. Under 29 CFR 1910.1200 Appendix D, Table D.1, Section 6 gives (a) personal precautions, protective equipment and emergency procedures, and (b) methods and materials for containment and cleaning up. Many sheets also add environmental precautions, such as keeping the product out of drains and waterways, which Table D.1 does not list as a sub-item. The section informs the response to a release. How a release is handled in a workplace depends on its size and on the employer's plans: 1910.120 separates the response to an incidental release that employees in the immediate release area can absorb, neutralize or otherwise control from an emergency response to an uncontrolled release (1910.120(a)(3), (q)).

Sources & verification

Checked against the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.

A related free tool

The free SDS Gap Analyzer covers a task related to Section 12: Ecological Information. Read the rule above first, then use the tool for your own workplace.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.

Your account keeps working as usual. Cancel anytime.