Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

General safety term · Glossary

NFPA 704 Diamond

The NFPA “fire diamond”: a four-quadrant marking from NFPA 704, a private consensus standard of the National Fire Protection Association and not an OSHA rule. NFPA describes it as a simple, readily recognized, and easily understood system of markings that provides an immediate general sense of the hazards of a material and their severity as they relate to emergency response. Blue (health), red (flammability) and yellow (instability) are each rated from 0 (minimal) to 4 (severe), and a white quadrant holds special-hazard symbols, such as OX for an oxidizer or a W with a bar through it for a material that reacts with water. It is a different system from the GHS labels of OSHA's Hazard Communication standard. Whether it is used at a site follows from the employer's choice or from a rule outside OSHA that adopts it.

Also known as: fire diamond, NFPA hazard diamond, 704 placard

NFPA 704 Diamond at a glance

  • Four quadrants: blue = health, red = flammability, yellow = instability, white = special hazards.
  • Blue, red and yellow are rated 0 (minimal) to 4 (severe), per NFPA's description of the system.
  • White holds symbols and not numbers. OX (oxidizer) and a W with a bar through it (reacts with water) are the common ones; SA (simple asphyxiant) appears on some markings. Which symbols are in use depends on the edition of NFPA 704 that applies; NFPA's page lists the 2027 edition as current.
  • NFPA 704 is for emergency response, a general sense of the hazards, and not a full hazard communication for workers. It gives no compatibility, quantity or PPE detail, which come from the SDS and the site's emergency plan.
  • For a shipped container, 1910.1200(f)(1) lists the label elements, and an NFPA diamond does not replace them. OSHA's letter of March 4, 2014 says an HMIS label may be added on a shipped container as long as it does not contradict or cast doubt on the label information listed in (f)(1) or impede the user's ability to identify that information.
  • For containers in the workplace, 1910.1200(f)(6)(ii) allows the product identifier plus words, pictures, symbols, or a combination that provide at least general information regarding the hazards and, together with the other information immediately available to employees under the hazard communication program, give employees the specific hazard information. A system built on an NFPA 704 diamond or on HMIS labels has to meet that provision as a whole.

In plain English

The diamond-shaped hazard marking you see on tanks and building doors: four colored boxes, with numbers from 0 to 4 in three of them. It gives responders a general sense of a material's hazards for emergency response. The SDS and the plan for the site carry the product details.

What the source says, in summary

NFPA 704 presents a simple, readily recognized, and easily understood system of markings that provides an immediate general sense of the hazards of a material and the severity of these hazards as they relate to emergency response.
NFPA 704 (private standard, not an OSHA rule), as described on NFPA's pageSummarized, not quoted: read the source for its operative wording.

In context

An industrial-hygiene, exposure-control, or program-management concept that applies across OSHA standards and workplaces.

29 CFR 1910 / 1926

Example

In this invented illustration, a placard on a tank of a fictional liquid reads blue 3, red 0, yellow 1 and white OX. A responder reads it as a health rating of 3 on the 0 to 4 scale, no flammability rating, a low instability rating and an oxidizer. The numbers give a general sense of the hazards for emergency response. The SDS of the actual product gives its details, and the label of a shipped container follows 1910.1200(f)(1).

Why it matters

The fire diamond is what a responder can read from a distance before approaching a building or a spill, and it gives a general sense of the hazards, not a full picture. It is a responder tool and not worker hazard communication on its own: an NFPA diamond does not replace the label elements of a shipped container, and for in-plant containers it can be one part of a workplace labeling system that meets 1910.1200(f)(6)(ii). The SDS and the site's emergency plan hold the product details.

NFPA 704 vs. GHS labels

NFPA 704 rates hazards 0 to 4 for emergency response. HMIS is a different system for informing workers, with its own ratings. GHS labels (pictograms, signal word, hazard statements) are the worker hazard communication that 1910.1200 calls for on shipped containers. They look similar but serve different audiences, so a diamond alone does not replace the shipped-container label, while a workplace labeling system that includes an NFPA diamond or HMIS labels has to meet 1910.1200(f)(6)(ii) as a whole.

The NFPA 704 fire diamond

Quadrant (color)HazardScale
Blue (left)Health0 (minimal) to 4 (severe)
Red (top)Flammability0 to 4
Yellow (right)Instability0 to 4
White (bottom)Special hazards (OX, W with a bar, SA on some markings)Symbols, not a number

NFPA 704 Diamond: frequently asked questions

What is NFPA 704 Diamond?
The NFPA “fire diamond”: a four-quadrant marking from NFPA 704, a private consensus standard of the National Fire Protection Association and not an OSHA rule. NFPA describes it as a simple, readily recognized, and easily understood system of markings that provides an immediate general sense of the hazards of a material and their severity as they relate to emergency response. Blue (health), red (flammability) and yellow (instability) are each rated from 0 (minimal) to 4 (severe), and a white quadrant holds special-hazard symbols, such as OX for an oxidizer or a W with a bar through it for a material that reacts with water. It is a different system from the GHS labels of OSHA's Hazard Communication standard. Whether it is used at a site follows from the employer's choice or from a rule outside OSHA that adopts it.
What do the NFPA 704 colors mean?
Blue is health, red is flammability and yellow is instability, each rated 0 (minimal) to 4 (severe). White is for special hazards, such as OX for an oxidizer or a W with a bar for a material that reacts with water. NFPA 704 is a private standard for emergency response, not an OSHA rule.
What do the NFPA numbers 0 to 4 mean?
They rate the severity of each hazard as it relates to emergency response: 0 is minimal and 4 is severe. The rating gives a general sense of the hazard, and the SDS of the product gives the details.
Is NFPA 704 the same as a GHS label?
No. NFPA 704 is a hazard rating for emergency response, while the GHS label elements of 1910.1200(f)(1) are the worker hazard communication on a shipped container, and an NFPA diamond does not replace them. For containers in the workplace, 1910.1200(f)(6)(ii) allows words, pictures, symbols or a combination that provide at least general hazard information, and a system built on an NFPA diamond or HMIS labels has to meet that provision as a whole.

Related terms

Free tools for this

Governing OSHA standards

More General Safety terms

Arc Flash

An arc flash is the sudden release of thermal energy from an electrical arc fault, a short circuit that jumps through the air between energized parts. The arc can reach temperatures over 35,000°F (nearly four times the surface of the sun), causing severe burns, igniting clothing, and driving an explosive pressure wave known as the arc blast. OSHA has no single “arc-flash standard”. Its electrical rules apply instead: 29 CFR 1910.333 and 1910.335 for work practices and PPE, and 1910.269 for electric power work. The analysis method (arc-flash boundary, incident energy, arc-rated PPE) comes from NFPA 70E, a consensus standard that OSHA has not adopted; OSHA and employers can use it as a guide for hazard analysis and controls (OSHA interpretation 2006-11-14).

Experience Modification Rate (EMR)

A workers' compensation insurance multiplier that adjusts an employer's premium to reflect its own payroll and loss record compared with the expected experience of employers in the same classification. A mod of 1.00 leaves the premium unchanged (the unity mod). A mod above 1.00, a debit mod, raises the premium, and one below 1.00, a credit mod, lowers it. The mod multiplies the premium calculated before the modification. It's set by rating bureaus (NCCI or a state bureau) under each state's rules, not by OSHA.

Action Level

An airborne concentration of a substance, below the exposure limit, at which certain provisions of an OSHA standard begin to apply. Which provisions depend on the standard: they can include exposure assessment or monitoring, training and medical surveillance, each with its own trigger. The action level is set in each standard. For respirable crystalline silica it is 25 µg/m³ as an 8-hour TWA, half the 50 µg/m³ PEL; for lead it is 30 µg/m³ against a PEL of 50 µg/m³ (1910.1025), and for formaldehyde 0.5 ppm against a PEL of 0.75 ppm (1910.1048).

Administrative Controls

Changes to how and when work is done that reduce a worker's exposure without changing the hazard itself. NIOSH places administrative controls fourth in the hierarchy of controls, below elimination, substitution and engineering controls and above personal protective equipment, and gives examples such as work process training, job rotation, adequate rest breaks, limiting access to hazardous areas or machinery, and adjusting line speeds. Housekeeping, written procedures and signage fit the same description. The hierarchy is a preference order. What an OSHA standard calls for is in that standard's own words.

Biological Exposure Index (BEI)

An ACGIH guidance value for evaluating biological monitoring results. A BEI generally represents the level of a determinant most likely to be observed in specimens from healthy workers exposed at the TLV-TWA level. The determinant can be the chemical itself, one or more metabolites, or a characteristic, reversible biochemical change induced by the chemical, measured in a specimen such as blood, urine or exhaled breath. BEIs do not indicate a sharp distinction between hazardous and nonhazardous exposures, and they are advisory: an OSHA standard that calls for biological monitoring sets its own terms.

California Proposition 65

California's Safe Drinking Water and Toxic Enforcement Act of 1986. As OEHHA describes it, businesses give a “clear and reasonable” warning before knowingly and intentionally exposing anyone to a chemical on the state's list, unless the business can show that the anticipated exposure will not pose a significant risk of cancer or is significantly below levels observed to cause birth defects or other reproductive harm. The list has grown to approximately 900 chemicals. The warning requirement takes effect one year after a chemical is listed, and businesses with less than 10 employees and government agencies are exempt. The law also prohibits knowingly discharging listed chemicals into sources of drinking water. It is a California law, and the test is the exposure a business causes, not the presence of a listed chemical alone.

CAS Number

A numerical identifier assigned by CAS (Chemical Abstracts Service, a division of the American Chemical Society) to a substance registered in the CAS REGISTRY. CAS describes a CAS Registry Number as a unique and unambiguous identifier for a specific substance. Substances are added when they are identified in literature being indexed for the CAS Content Collection or when an entity requests a number for a novel substance. The number has up to 10 digits in three groups separated by hyphens: 2 to 7 digits, 2 digits, and one check digit (for example, 67-64-1 for acetone). CAS is the source and final authority for CAS Registry Numbers, and other resources may associate an incorrect number with a compound.

Ceiling Limit

An exposure limit that may not be exceeded at any instant during the workday. In OSHA's Z-tables it is marked with a “C” before the value. Unlike an 8-hour TWA (an average) or a 15-minute STEL, a Table Z-1 ceiling applies to a single moment; if instantaneous monitoring is not feasible, it is assessed as a 15-minute time-weighted average that may not be exceeded at any time during the working day. Table Z-2 instead uses an acceptable ceiling concentration with a separate acceptable maximum peak allowed for a limited time (1910.1000(a)(1), (b)(2)-(3)).

Sources & verification

Checked against NFPA, the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.

A related free tool

The free Chemical Compatibility Matrix covers a task related to NFPA 704 Diamond. Read the rule above first, then use the tool for your own workplace.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.