What 29 CFR 1926.702 requires (plain English)
29 CFR 1926.702 sets the equipment-specific safety requirements for concrete and masonry construction, covering bulk cement storage, concrete mixers, power concrete trowels, buggies, pumping systems, concrete buckets, tremies, bull floats, masonry saws, and lockout/tagout during maintenance and repair.
Under (f)(1), concrete buckets equipped with hydraulic or pneumatic gates have positive safety latches or similar devices to prevent premature or accidental dumping. Concrete mixers with one-cubic-yard-or-larger loading skips must have a mechanical device to clear the skip and guardrails on each side (1926.702(b)); concrete pumping systems must have discharge-pipe supports designed for 100 percent overload and positive fail-safe joint connectors on compressed air hoses (1926.702(e)); and bulk cement storage must have conical or tapered bottoms, a mechanical or pneumatic means of starting the flow, and lockout and tagout of the ejection system before anyone enters (1926.702(a)). Tremie sections are secured with wire rope or the equivalent in addition to their couplings (g), bull float handles that could contact energized conductors are nonconductive or insulated (h), masonry saws have a semicircular enclosure over the blade (i), and equipment such as compressors, mixers, screens and pumps is locked out and tagged before maintenance or repair (j).
1926.702 works with the general concrete standard (1926.701), under which no employee works under concrete buckets while they are being elevated or lowered into position, and the formwork standard (1926.703). Concrete buggy handles do not extend beyond the wheels on either side of the buggy (d); concrete buckets are designed to prevent concrete from hanging up on top and the sides (f)(2); masonry saw enclosures incorporate a method for retaining blade fragments (i)(2); the tags read Do Not Start or similar language (j)(2). The general industry lockout/tagout standard 1910.147 is not imported automatically into construction.