OSHA term · Glossary
Assigned Protection Factor (APF)
Verified vs OSHA sources · 2026-10-27
The workplace level of respiratory protection that a respirator or class of respirators is expected to provide to employees when the employer implements a continuing, effective respiratory protection program (29 CFR 1910.134(b)). OSHA lists APFs in Table 1 of 1910.134(d)(3)(i)(A), and note 2 of the table says they are only effective when the employer implements such a program, including training, fit testing, maintenance and use requirements. An APF of 10 therefore means a class of respirators is expected to hold the wearer's exposure to about one-tenth of the concentration outside the respirator under a program that works as the standard describes; it is a planning value for a class of respirators, not a measurement of the air an individual worker breathes. Examples from Table 1: air-purifying quarter mask 5, half mask 10 (this category includes filtering facepieces and elastomeric half masks) and full facepiece 50; PAPR or continuous-flow supplied-air loose-fitting facepiece 25; helmet or hood 25, or 1,000 only with manufacturer evidence of that performance (note 4); tight-fitting full-facepiece PAPR 1,000; and SCBA in pressure-demand or other positive-pressure mode 10,000. The APF is used to determine the Maximum Use Concentration (MUC = APF × PEL) (1910.134(b)).
Also known as: APF, protection factor
On this page
Assigned Protection Factor (APF) at a glance
- Table 1 of 29 CFR 1910.134(d)(3)(i)(A) lists the APFs, and the employer uses them to select a respirator that meets or exceeds the required level of employee protection. Air-purifying respirators: quarter mask 5, half mask 10, full facepiece 50. Table note 3 says the half mask category includes filtering facepieces and half masks with elastomeric facepieces.
- Powered air-purifying respirators (PAPR): half mask 50, tight-fitting full facepiece 1,000, loose-fitting facepiece 25. A helmet or hood is 25, or 1,000 only if the manufacturer provides evidence that testing demonstrates performance at a level of protection of 1,000 or greater (Table 1 note 4); without that evidence it is treated as a loose-fitting facepiece respirator at 25. Supplied-air respirators in continuous-flow mode have the same values.
- Supplied-air respirators: demand mode half mask 10 and full facepiece 50; pressure-demand or other positive-pressure mode half mask 50 and full facepiece 1,000. SCBA: demand mode full facepiece 50; pressure-demand or other positive-pressure mode 10,000, the highest value in the table.
- Maximum Use Concentration: the MUC can be determined mathematically by multiplying the APF of a respirator by the OSHA PEL, STEL or ceiling limit (MUC = APF × PEL; 1910.134(b)). The employer selects a respirator that keeps the employee's exposure, measured outside the respirator, at or below the MUC (1910.134(d)(3)(i)(B)(1)).
- MUCs are not applied to IDLH conditions, where respirators listed for IDLH conditions in paragraph (d)(2) are used instead (1910.134(d)(3)(i)(B)(2)). When the calculated MUC exceeds the IDLH level or the performance limits of the cartridge or canister, the maximum MUC is set at that lower limit (1910.134(d)(3)(i)(B)(3)).
- Table 1 note 2 says the APFs are only effective when the employer implements a continuing, effective respirator program, including training, fit testing, maintenance and use requirements. Note 1 says employers may select respirators assigned for higher concentrations for use at lower concentrations. Note 5 says the APFs do not apply to respirators used solely for escape.
- For a combination respirator, such as an airline respirator with an air-purifying filter, the APF is the one appropriate to the mode of operation in use (1910.134(d)(3)(i)(A)).
In plain English
A number that shows how much a respirator class is expected to cut exposure. It is a program-level value, not a reading inside one worker's mask. An APF of 10 means about one-tenth of the concentration outside the respirator, and 50 means about one-fiftieth. Multiply the APF by the exposure limit to get the Maximum Use Concentration (MUC), the highest concentration the respirator class is expected to handle. The MUC is capped at the IDLH level or the cartridge limit when either is lower.
What the rule says
“Assigned protection factor (APF) means the workplace level of respiratory protection that a respirator or class of respirators is expected to provide to employees when the employer implements a continuing, effective respiratory protection program as specified by this section.”
In context
An enforcement, recordkeeping, or general-duty concept under the Occupational Safety and Health Act and 29 CFR. These terms define how OSHA inspects, cites, and penalizes employers.
Where this is written in OSHA's rules
- 29 CFR 1910.134(d)(3)(i)Read on eCFR / OSHA.gov
- 29 CFR 1910.134(b)Read on eCFR / OSHA.gov
Example
In this invented illustration, a contaminant has a PEL of 5 mg/m³ and a worker's measured exposure is 40 mg/m³. Dividing exposure by the PEL gives a required protection factor of 8, so a half-mask air-purifying respirator (APF 10) is within range: its Maximum Use Concentration is 10 × 5 = 50 mg/m³, above the 40 mg/m³ exposure. If exposure were instead 400 mg/m³, the required protection factor would be 400 ÷ 5 = 80. The half mask's MUC (50 mg/m³) would be exceeded, and so would a full facepiece's (APF 50, MUC 250 mg/m³) and a half-mask PAPR's (APF 50). A class with an APF of at least 80 in Table 1, such as a tight-fitting full-facepiece PAPR (APF 1,000) or a full-facepiece supplied-air respirator in continuous-flow or pressure-demand mode (APF 1,000), could be considered. Whether any of them can be used depends on the IDLH status of the atmosphere, oxygen content, the form of the contaminant, the filter or cartridge limits (the MUC is capped at the lower of the IDLH level and those limits), NIOSH certification and the respiratory protection program. MUCs are not applied to IDLH conditions (1910.134(d)(3)(i)(B)(2)).
Why it matters
The APF turns a respirator class into a concrete usable concentration through the MUC (APF × PEL). A respirator whose MUC is below the actual exposure leaves the worker overexposed even though the worker is wearing a respirator. Respirators sit low in the hierarchy of controls, so matching the APF to the exposure and staying within the MUC, the IDLH level and the cartridge limits is part of selecting one.
APF vs. fit factor
These sound similar and are different numbers. The ASSIGNED PROTECTION FACTOR (APF) is a value from Table 1: the protection a respirator CLASS is expected to provide when the employer implements an effective program (for example, half masks get an APF of 10). The FIT FACTOR is a result from a quantitative fit test: a quantitative estimate of how well one respirator fits one person at that test (for example, a fit factor of 150). A quantitative fit test is passed with a fit factor of 100 or more for a tight-fitting half facepiece, but the protection used to select a respirator for the workplace is the APF in Table 1, not the individual fit factor.
OSHA Assigned Protection Factors: Table 1 (29 CFR 1910.134)
| Respirator Type | APF |
|---|---|
| Half mask, air-purifying (includes filtering facepieces and elastomeric half masks) | 10 |
| Full facepiece, air-purifying | 50 |
| Loose-fitting facepiece (PAPR or continuous-flow supplied-air) | 25 |
| Helmet or hood (PAPR or continuous-flow supplied-air) | 25, or 1,000 only with manufacturer evidence (note 4) |
| Tight-fitting full-facepiece PAPR | 1,000 |
| Demand-mode SCBA / SAR, full facepiece | 50 |
| Pressure-demand or other positive-pressure SCBA, full facepiece | 10,000 |
Assigned Protection Factor (APF): frequently asked questions
- What is Assigned Protection Factor (APF)?
- The workplace level of respiratory protection that a respirator or class of respirators is expected to provide to employees when the employer implements a continuing, effective respiratory protection program (29 CFR 1910.134(b)). OSHA lists APFs in Table 1 of 1910.134(d)(3)(i)(A), and note 2 of the table says they are only effective when the employer implements such a program, including training, fit testing, maintenance and use requirements. An APF of 10 therefore means a class of respirators is expected to hold the wearer's exposure to about one-tenth of the concentration outside the respirator under a program that works as the standard describes; it is a planning value for a class of respirators, not a measurement of the air an individual worker breathes. Examples from Table 1: air-purifying quarter mask 5, half mask 10 (this category includes filtering facepieces and elastomeric half masks) and full facepiece 50; PAPR or continuous-flow supplied-air loose-fitting facepiece 25; helmet or hood 25, or 1,000 only with manufacturer evidence of that performance (note 4); tight-fitting full-facepiece PAPR 1,000; and SCBA in pressure-demand or other positive-pressure mode 10,000. The APF is used to determine the Maximum Use Concentration (MUC = APF × PEL) (1910.134(b)).
- What does an assigned protection factor of 10 mean?
- An APF of 10 means that a class of respirators is expected to provide a level of protection that holds the wearer's exposure to about one-tenth of the concentration outside the respirator, when the employer implements a continuing, effective respiratory protection program (1910.134(b)). Table 1 gives half-mask air-purifying respirators an APF of 10. It is an expected level for a class of respirators, not a measurement of the air inside an individual worker's respirator. To find the highest concentration for a respirator class, multiply the APF by the exposure limit (the Maximum Use Concentration).
- How do you calculate the Maximum Use Concentration (MUC)?
- The MUC can be determined mathematically by multiplying the APF of a respirator by the OSHA PEL, STEL or ceiling limit (MUC = APF × PEL; 1910.134(b)). For example, a full facepiece (APF 50) used against a contaminant with a 5 mg/m³ PEL has an MUC of 250 mg/m³. The employer selects a respirator that keeps exposure, measured outside the respirator, at or below the MUC (1910.134(d)(3)(i)(B)(1)). MUCs are not applied to IDLH conditions (1910.134(d)(3)(i)(B)(2)), and when the calculated MUC exceeds the IDLH level or the performance limits of the cartridge or canister, the maximum MUC is that lower limit (1910.134(d)(3)(i)(B)(3)).
- Which respirator has the highest assigned protection factor?
- Table 1 gives its highest value, 10,000, to SCBA in pressure-demand or other positive-pressure mode. By contrast, a half-mask air-purifying respirator has an APF of 10. Atmospheres that are immediately dangerous to life or health are handled in paragraph (d)(2) of the standard, which lists the respirators for them, and MUCs are not applied there.
Related terms
Free tools for this
More OSHA terms
The action an employer takes to fix a cited violation or eliminate a hazard OSHA identified during an inspection. The abatement date starts as the date set in the citation and can move later through an approved petition for modification of abatement date (PMA), a settlement or, for a contested item, the final order. Within 10 calendar days after that date the employer must certify to OSHA that each cited violation was abated, unless the compliance officer saw the fix within 24 hours during the on-site inspection and noted it in the citation (29 CFR 1903.19(b)(2), (c)). For an item left uncorrected, OSHA can assess a penalty of up to $16,550 per day.
Area DirectorThe senior OSHA official in charge of a specific OSHA Area Office, the local unit that runs inspections and enforcement in its geographic territory. The Area Director reviews the inspector's report, issues citations, determines the proposed penalties, holds informal conferences with employers, and can enter into informal settlement agreements before a case is contested; once an employer contests, the Regional Solicitor's office takes part. When a Compliance Safety and Health Officer (CSHO) completes an inspection, it's the Area Director who issues the citation (29 CFR 1903.14(a), 1903.15(b); OSHA Field Operations Manual, ch. 7).
Bureau of Labor Statistics (BLS)The federal statistical agency within the U.S. Department of Labor that collects, analyzes, and publishes data on workplace injuries, illnesses, and fatalities. BLS conducts the annual Survey of Occupational Injuries and Illnesses (SOII), a survey of randomly selected employers built on their OSHA injury and illness records, and the Census of Fatal Occupational Injuries (CFOI). OSHA's Site-Specific Targeting (SST) program builds its inspection lists from the Form 300A data that employers submit to OSHA under 29 CFR 1904.41, not from the BLS survey.
Competent PersonUnder OSHA's construction standards, a person who is capable of identifying existing and predictable hazards in the surroundings or working conditions, and who has the authorization to take prompt corrective measures to eliminate them. The role requires both knowledge and the authority to act, and is mandated by name in many specific standards: excavations, scaffolds, fall protection, asbestos, and more.
CitationThe formal written notice OSHA issues to an employer after an inspection. It describes each alleged violation with particularity, names the provision alleged to have been violated, and fixes a reasonable time to correct (abate) it. The proposed penalty comes in a separate notice of proposed penalty, sent with or after the citation, and that notice can also say that no penalty is proposed. OSHA must issue a citation with reasonable promptness and no later than six months after the violation occurred (OSH Act §9; 29 CFR 1903.14(a), 1903.15(a)).
Closing ConferenceThe meeting at the end of an OSHA inspection where the compliance officer confers with the employer and the employee representatives, together or separately, and informally advises them of any apparent violations found. The employer can also bring pertinent information about conditions in the workplace to the compliance officer's attention. The closing conference discusses what was observed and the parties' rights. It issues no citation and sets no penalty: those come later in the written Citation and Notification of Penalty (29 CFR 1903.7(e); OSHA Field Operations Manual, ch. 3).
Compliance Officer (CSHO)An OSHA Compliance Safety and Health Officer, the inspector who conducts workplace inspections. A CSHO presents credentials (a photo ID and a serial number), holds the opening conference, performs the walkaround, collects evidence, interviews employees, and reports the findings to the Area Director, who reviews the report and decides whether to issue a citation. CSHOs may specialize as safety specialists or as industrial hygienists, and the scope of each inspection is explained at the opening conference (29 CFR 1903.7(a), 1903.14(a)).
ContestAn employer's formal challenge to an OSHA citation, proposed penalty, or abatement date. To contest, the employer notifies the OSHA Area Director in writing, with a notice postmarked within 15 working days of receiving the notice of proposed penalty (29 CFR 1903.17(a)). The Area Director forwards it to the independent Occupational Safety and Health Review Commission (OSHRC), a federal agency that resolves these disputes. Without a timely notice, the citation and proposed penalty become a final order that no court or agency reviews (29 CFR 1903.15(a)).
Sources & verification
- 29 CFR 1910.134(d)(3)(i) (eCFR / OSHA.gov)
- 29 CFR 1910.134(b) (eCFR / OSHA.gov)
- OSHA: 29 CFR 1910.134 (Respiratory Protection)
- OSHA: Respiratory Protection (Safety and Health Topics)
- eCFR: 29 CFR 1910.134, Respiratory protection
Checked against the eCFR and OSHA.gov. Last reviewed 2026-10-27. This glossary is general information, not legal advice; OSHA State-Plan states (e.g. California, Michigan) may adopt stricter requirements.
A related free tool
The free Respirator Fit-Test Method Selector covers a task related to Assigned Protection Factor (APF). Read the rule above first, then use the tool for your own workplace.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.