Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

Data & Research

OSHA air samples compared with federal, NIOSH and California limits

By HazComFastPublished November 16, 2026Updated November 18, 202611 min read
OSHA air samples compared with federal, NIOSH and California limits
HazComFastLast reviewed November 18, 2026

OSHA's public sampling files contain results at or below a federal exposure-limit value and above a lower NIOSH or California value. In a defined panel of 24 reported substances and particulate categories, HazComFast identified 3,481 positive, unqualified results marked by OSHA as using an eight-hour calculation. Thirty-six fell between the federal and NIOSH reference values. Fifty-eight fell between the federal and California reference values.

Those counts describe different comparison panels and can overlap. They must not be added. The analysis applies reference values checked in November 2026 to samples collected from 2014 through 2025. It does not establish historical violations, national exposure prevalence or the safety of a workplace.

What the study found

FindingResult
Personal, nonblank source records dated 2014 through 2025278,119
Positive, unqualified, single records marked as using an eight-hour calculation in the retained panel3,481
Inspections represented by those retained records1,347
Retained records between a lower NIOSH value and the federal value36
Retained records between a lower California value and the federal value58

The NIOSH comparison with a lower reference covers 165 retained records across eight reported categories. The California comparison covers 1,097 across eleven categories. The different denominators reflect which reference values are lower and which comparisons can be supported by the reported substance and mass basis.

Download the study data (Excel).

Three reference systems can give different answers

A federal permissible exposure limit, a NIOSH recommended exposure limit and a California permissible exposure limit serve different purposes. A federal PEL is an enforceable limit where that federal provision applies. A NIOSH REL is a recommendation. California has its own enforceable limits within its jurisdiction. A California value used to screen a result from another jurisdiction does not become that jurisdiction's legal limit.

The reference system also determines the averaging period. The federal values used here are eight-hour time-weighted-average values from 29 CFR 1910.1000. California's TWA comparison is drawn from 8 CCR 5155, Table AC-1. NIOSH generally defines TWA RELs for workdays of up to ten hours during a forty-hour workweek in the Pocket Guide introduction. Substance-specific recommendations can specify another period. For chromium metal, NIOSH specifies an eight-hour TWA in Appendix C.

For example, the listed federal TWA value for toluene is 200 ppm, the NIOSH TWA recommendation is 100 ppm and California's TWA value is 10 ppm. These are comparisons of the listed TWA concentrations. Toluene also has short-term or ceiling provisions that this table does not evaluate.

The separate history of OSHA exposure limits explains the federal tables' regulatory background. The comparison here concerns the defined retained records and listed reference concentrations.

The reference values and their units are available in the comparison table. A blank comparison means that no numeric comparison was assigned for this analysis. It does not establish that a chemical lacks a recommended limit or other protective requirements.

The records retained for the main comparison

OSHA's Chemical Exposure Health Data files include personal samples, area samples and bulk samples. They also distinguish individual sample results from records marked as using an eight-hour calculation. Those distinctions affect what a result can be compared with. OSHA explicitly warns that individual sampling results may not be directly comparable with its PELs on the dataset page.

This study retained personal, nonblank records with sampling dates in 2014 through 2025. For the main comparison, a result also had to meet all of the following conditions:

  • The eight-hour-calculation field was explicitly marked Y.
  • Exactly one Y record existed for that inspection, sampling number and substance code.
  • The concentration was a finite number greater than zero, with no result qualifier.
  • The unit matched the reference table: ppm or mg/m³.
  • The reported substance and the reference could be compared on the retained basis.

A group with several Y records was excluded from the main comparison. A record already marked as using an eight-hour calculation was used as published, without multiplying it by sampling time and normalizing it a second time.

These rules produced 3,481 retained records. They are a selected subset of the source files. Percentages within that subset describe retained quantified results, not all measurements, all inspected workers or all U.S. workplaces.

Results between the reference values

A result is counted as between two references when its published concentration is greater than the lower value and less than or equal to the federal TWA reference value. This is a numerical comparison. The term does not mean that the establishment was compliant with every applicable provision.

Reported categoryRetained recordsBetween federal and NIOSHBetween federal and California
2-Butoxyethanol641
Toluene2007
Chromium metal and insoluble salts5411
Cobalt metal dust and fume1323
Nickel metal and insoluble compounds3029Not assigned
PNOR (total dust)945Not assigned45
Sulfuric acid4Not assigned1

The table lists categories with at least one between-reference result. Other retained categories remain in the downloadable tables, including categories whose listed values were equal. "Not assigned" means that the comparison was not assigned or that the alternative reference was not lower. A zero means that the comparison was made and found no retained result in that interval.

Nickel accounts for 29 of the 36 between-reference results in the NIOSH comparison. Total particulates not otherwise regulated account for 45 of the 58 in the California comparison. Those concentrations of counts make a pooled percentage sensitive to the chemical mix. A single percentage should not be read as a general difference between federal, NIOSH and California protection.

Within the eight-category NIOSH panel, 42 results were above the lower NIOSH reference. Thirty-six of those were at or below the federal reference, and six were above both. Within the eleven-category California panel, 149 were above the lower California reference. Fifty-eight were at or below the federal reference, and 91 were above both.

These panels have different substance coverage. Their results cannot show which jurisdiction has the higher overall workplace exposure rate.

Why nondetections are excluded from the main result

A nondetection does not establish that the concentration was zero. It means the laboratory did not quantify the substance at the applicable reporting threshold. To compare that result with a low exposure benchmark, the actual reporting limit and its units matter.

Among the single Y records with a matching unit, 4,984 had a nondetection or upper-bound qualifier. They were excluded from the main comparison. Twenty-three approximate results were also excluded. Records with other qualifiers, missing or nonfinite concentrations, or concentrations at or below zero were also excluded.

The analysis does not estimate a reporting limit from the smallest detected values. A low detected value on another sample does not establish the reporting limit for the sample under review. It can come from a different air volume, method, laboratory run or reporting convention.

For an employer reviewing a laboratory report, the useful questions are specific: What is the reporting limit? Is it expressed as concentration or mass? What air volume does the calculation use? Is the reporting limit low enough for the selected benchmark? If those details are missing, the comparison remains unresolved.

Excluding nondetections also changes the denominator. The retained positive results cannot be used to estimate the proportion of all samples above a limit. Their purpose here is to identify observed numerical differences that remain after uncertain nondetection bounds are removed.

Chemical form and mass basis change the comparison

Iron and zinc. An elemental result from a metals analysis does not establish the compound present in the airborne material. Converting iron to iron oxide or zinc to zinc oxide requires the relevant chemical form and reporting basis. The main comparison excludes the iron-oxide and zinc-oxide groups because the reported codes alone do not resolve that distinction.

Nickel. The source category covers nickel metal and insoluble compounds. California lists different TWA values for those forms. Federal and NIOSH numeric comparisons are included for the combined reported category; no California comparison is assigned without the chemical-form information needed to choose its reference.

Titanium dioxide. NIOSH has numeric recommendations for fine and ultrafine titanium dioxide in Current Intelligence Bulletin 63. The available total-dust records do not establish the particle characterization needed to apply those recommendations. California's listing also introduces an elemental titanium mass basis. The main panel excludes titanium dioxide because the records do not resolve the particle characterization and mass basis needed for these comparisons.

Manganese. The federal value in the candidate panel is a ceiling. An average below a ceiling cannot establish that no short peak exceeded it. Manganese was excluded from the TWA comparison.

The retained chromium category concerns chromium metal and insoluble salts. Its result does not measure hexavalent chromium exposure. Other substance-specific standards, short-term limits, skin designations and mixture provisions require their own assessment. The OSHA annotated tables are a starting point for locating these differences.

A separate check using records sampled for exactly 480 minutes

The eight-hour-calculation flag comes from the source dataset. A separate descriptive comparison covers positive, unqualified records marked N, with exactly one N record per inspection, sampling number and substance code, a compatible unit and a reported sampling duration of exactly 480 minutes.

That set contained 350 records across the retained panel. The lower-NIOSH comparison covered 26 of them, with four between the reference values. The lower-California comparison covered 121, also with four between the references.

This is a separate sensitivity check. It is not combined with the main panel. A recorded duration of 480 minutes does not, on its own, confirm sampling quality, exposure representativeness or the applicable legal standard.

What a safety manager can use from the findings

Start with the laboratory report and the task. Identify the substance, its chemical form and the aerosol fraction if relevant. Confirm the concentration unit, averaging period and reporting limit. Then select the applicable enforceable requirement and any additional health-based benchmark used by the employer.

Keep the comparisons separate. A federal reference, a California requirement and a NIOSH recommendation should each have its own label and source. If a result crosses a lower recommendation, review the controls and sampling plan with the industrial hygienist responsible for the assessment. A concentration below one reference does not settle short-term peaks, skin exposure, mixtures or all health risks.

The downloadable workbook contains the study tables and a review worksheet. It keeps the reported value, unit, averaging basis, benchmark source and nondetection reporting limit visible. It does not select a respirator or declare a workplace compliant. For chemical information used alongside monitoring, see the SDS management guide and chemical-resistant glove selection.

Data and methods

The study uses thirteen OSHA annual files labeled 2014 through 2026, available on November 16, 2026. Samples are selected by the date they were taken. A file from a later year can contain earlier samples.

Two malformed rows are excluded. Repeated records are identified by inspection, sampling, field and laboratory identifiers, substance code, result, sampling time and sampling date. When that key repeats, the record from the latest annual file is kept. Other fields can still differ.

The files contained 543,110 parsed records. Removing 8,867 repeats left 534,243. Selecting personal, nonblank samples within the date range left 278,119 records. Of the 28 substance or particulate categories considered, the four exclusions described above left 24. The published tables list each retained category and its reference value.

There were 16,861 records marked Y in the main panel. Requiring one record per group and a compatible unit left 9,139. Excluding qualified results and concentrations that were invalid or not positive left 3,481. The eligibility table gives the counts for each category.

Where the comparison stops

OSHA selects workplaces for enforcement sampling. Those samples cannot tell us how common an exposure is across U.S. workplaces. Cases appear in the public data after closure, and annual files differ in coverage. Changes in coding, substances sampled and available positive results also affect the comparison. The results cannot rank industries by danger or show a national exposure trend.

The federal reference values come from the general-industry tables. A sampled task may fall under a different sector rule, State Plan requirement or other provision. Applying a current value to an older sample does not establish which rule applied at the time. The comparison alone cannot determine an employer's legal compliance.

Sources and data

Suggested citation: HazComFast (2026). OSHA air samples compared with federal, NIOSH and California limits. Samples dated 2014 through 2025; data version November 16, 2026. Study page.

Federal OSHA penalty limits were last checked against the eCFR, OSHA.gov and the Federal Register on October 19, 2026, and HCS transition dates on June 23, 2026. Last reviewed November 18, 2026.

About This Article

Published by: HazComFast

Published: November 16, 2026

Last Updated: November 18, 2026

This content is for informational purposes only and does not constitute legal advice.

Ready to simplify your HazCom compliance?

HazComFast keeps your SDS library, GHS labels, and training records audit-ready, with the jobsite's SDS on the crew's phones.