Select chemical-resistant gloves for the product, the way contact occurs and the length of the task. Start with the product's safety data sheet (SDS), then obtain resistance data for the specific glove model. “Nitrile” or “chemical resistant” on a box leaves too much unanswered to make that decision.
In general industry, 29 CFR 1910.138(b) requires selection based on the glove's performance, the task, working conditions, duration of use and identified hazards. Construction employers must provide suitable protection under 1926.95. The written hazard-assessment certification in 1910.132(d)(2) belongs to the general-industry rule; construction employers should use the requirements that govern their work.
Start with the product's SDS
Use the SDS that matches the container's product identifier. A sheet for pure acetone cannot establish glove protection for every thinner containing acetone. Mixtures need their own evaluation.
Read Section 8 for exposure controls and personal protective equipment (PPE), Section 2 for hazards, and Sections 7 and 10 for handling conditions and chemical reactivity. If the supplier says only “wear suitable gloves,” request a specific recommendation and the evidence supporting it. OSHA's SDS guide explains these sections. The Section 8 task-assessment guide shows how to connect the sheet to workplace controls.
Keep the product identifier and SDS revision with the selection record. Recheck the decision when a supplier changes the formulation or the employer changes the dilution.
Permeation, penetration and degradation
These terms describe different ways protection can fail.
| Term | What happens | Information to obtain |
|---|---|---|
| Permeation | A chemical moves through the glove material at a molecular level. | Test chemical and concentration, glove model and thickness, test temperature, breakthrough time and permeation rate where reported. |
| Penetration | A chemical passes through an opening, such as a hole, seam or defect. | Glove construction, inspection instructions and relevant test results. |
| Degradation | Contact changes the material's physical properties. | Manufacturer data on swelling, softening, brittleness or loss of strength. |
A glove may remain visibly intact while a chemical permeates it. Inspecting for damage is necessary, but appearance alone cannot establish wearing time. The Canadian Centre for Occupational Health and Safety explains these failure mechanisms and the information used in selection.
ASTM F739 tests permeation under continuous contact. Its breakthrough result describes the test conditions, rather than a worker's safe service interval. Temperature, flexing and mixtures can affect performance in use; OSHA discusses those factors in its Technical Manual on dermal exposure.
A six-step glove selection process
1. Describe the contact
Record the commercial product, concentration and task. Pouring a liquid, wiping a part and reaching into a bath create different contact conditions.
Include residues on hoses, handles, tools and used wipes. Determine whether the glove faces occasional splashes, repeated wetting or immersion, and record how long the work lasts. Account for hot liquids, abrasion, sharp edges and liquid that could enter at the cuff.
2. Obtain data for the specific glove model
Request the manufacturer's chemical-resistance chart or a technical recommendation for the proposed model and thickness. Read the test definitions: a rating, a breakthrough time and a permeation rate describe different results. An empty chart entry means the evidence still needs to be obtained.
For a mixture, ask the manufacturer what supports the recommendation for that formulation. Selecting a glove from separate ingredient results calls for more than assuming the mixture will behave like its least favorable ingredient.
3. Reduce contact before relying on gloves
Consider whether a closed transfer system, dispensing equipment or a handling tool can keep hands away from the product. NIOSH's hierarchy of controls gives priority to eliminating or reducing exposure before relying on PPE.
Where gloves remain necessary, compare the manufacturer's data with the contact conditions described in step 1. Resolve missing information with the supplier before authorizing the task.
4. Check fit, grip and mechanical protection
Using clean equipment, have the employee perform the movements the task calls for. Check sizing, grip, reach, cuff position and operation of controls.
Evaluate cuts, punctures and abrasion as well as chemical contact. If the job calls for an overglove or another combination, check the complete arrangement against the manufacturers' instructions. Excess bulk or a loose fit can interfere with control of a tool.
Check for entanglement before using gloves near machinery. A glove can pull a hand into an exposed rotating or moving part. Resolve that hazard through guarding, isolation or a different work method while also controlling chemical contact. The Massachusetts Department of Public Health's machinery warning, hosted by CDC, addresses this hazard.
5. Establish removal and replacement rules
Give workers a replacement interval supported by the product, glove data and conditions of use. Include what to do after unexpected contact, visible damage or contamination inside the glove.
Follow the manufacturer's instructions for single use, reuse and decontamination. Explain how to remove contaminated gloves without transferring the chemical to skin, clothing or clean surfaces, and where used gloves go.
For general-industry work, 1910.132(f) requires instruction on when and which PPE is needed, its use, limitations, care and disposal. Employees must demonstrate understanding and proper use before performing work requiring the PPE. Have the employee show the removal method and explain the replacement triggers.
6. Keep the decision with the task
Record the selected model, size, supporting data and limits of use. The supervisor needs that information when ordering replacements or assigning someone else to the work.
Review the selection after a change in product, concentration, temperature, contact pattern, equipment or glove model.
Compare wiping with immersion
Consider two ways of using the same cleaner: wiping a part with a wetted cloth and cleaning a part in a liquid bath. The formulation may be the same, but the contact to evaluate changes.
| Task | What the selection needs to address |
|---|---|
| Wiping with a wetted cloth | Repeated wetting of fingers and palm, abrasion against the part, handling used wipes and removing the glove without spreading residue. |
| Handling a part in a bath | Sustained contact, bath concentration and temperature, depth of immersion, cuff coverage and a way to handle the part without liquid entering the glove. |
Ask the manufacturer whether its recommendation covers the intended task. A model recommended for occasional splashes needs further evaluation before immersion use.
Material families such as nitrile, neoprene, natural rubber, butyl and laminate help narrow the search for data. Color, thickness and descriptions such as “heavy duty” still need supporting performance information for the model.
Glove selection record
| Selection field | Task record |
|---|---|
| Product identifier and SDS revision | ____________________ |
| Chemical or mixture and concentration | ____________________ |
| Task and contact pattern | ____________________ |
| Duration, frequency and temperature | ____________________ |
| Glove manufacturer, model, size and thickness | ____________________ |
| Resistance chart or manufacturer response | ____________________ |
| Limits of the recommendation | ____________________ |
| Mechanical hazards and dexterity needed | ____________________ |
| Removal, replacement and reuse instructions | ____________________ |
| Employee instruction and responsible person | ____________________ |
| Review date and reasons for reassessment | ____________________ |
Attach the manufacturer's evidence so a later review can trace the decision.
Does OSHA specify one glove for each chemical?
1910.138 establishes a selection duty rather than a universal chemical-to-material table. OSHA's nonmandatory PPE selection guidance provides additional guidance on chemical resistance and working conditions.
Can a GHS pictogram determine glove selection?
A GHS pictogram communicates chemical hazards, sometimes several classes or categories through the same symbol. OSHA's pictogram QuickCard shows those groupings. Glove selection also needs the formulation, concentration, contact conditions and resistance data. The chemical PPE guide covers how hand protection fits with eye, face, body and respiratory protection.
Site-wide regulatory figures such as compliance dates and penalty amounts come from our regulatory source-of-truth modules, last checked against the eCFR, OSHA.gov, and the Federal Register on October 19, 2026. Last reviewed November 16, 2026.
About This Article
Published by: HazComFast
Published: November 16, 2026
Last Updated: November 16, 2026
- https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.138
- https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.95
- https://www.osha.gov/sites/default/files/publications/OSHA3514.pdf
- https://www.ccohs.ca/oshanswers/prevention/ppe/gloves.html
- https://www.osha.gov/otm/section-2-health-hazards/chapter-2/
- https://www.cdc.gov/niosh/hierarchy-of-controls/about/index.html
- https://stacks.cdc.gov/view/cdc/216121
- https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.132
- https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910SubpartIAppB
- https://www.osha.gov/sites/default/files/publications/OSHA3491QuickCardPictogram.pdf
This content is for informational purposes only and does not constitute legal advice.