A short talk on carbon monoxide for crews that run generators, heaters, saws or other engines near enclosed spaces. CO has no color, no smell and no taste, and its first symptoms can include a headache or dizziness. OSHA's permissible exposure limit is 50 ppm averaged over an 8-hour shift, in construction (29 CFR 1926.55, Table 1) and in general industry (29 CFR 1910.1000, Table Z-1).

All safety topics

At a glance

  • Carbon monoxide: permissible exposure limit of 50 ppm, 8-hour time-weighted average, in construction (29 CFR 1926.55, Table 1) and general industry (29 CFR 1910.1000, Table Z-1).
  • About 5 minutes to read the script out loud, then the three questions. The drill and the tables below add time if you use them.
  • Free PDF and Word file: the script, the questions, the rule and a 20-line sign-in sheet. No account, no email.

Read this to your crew

Today is carbon monoxide, CO. It comes out of anything that burns fuel: generators, propane and kerosene heaters, gas-powered saws, pressure washers, compressors, forklifts and trucks idling by a door. You cannot see it, smell it or taste it, and it can reach a deadly level in minutes in a room, a basement, a trailer or a tented area.

Engines run outside, away from doors, windows and air intakes, so the exhaust does not drift back in. An open door or a fan does not make an engine safe inside: CO can build up quickly in enclosed and partly enclosed spaces. When the work is inside, we use electric, battery or air-powered tools if they can be used safely.

Heaters are the winter version of the same problem. A fuel-burning heater inside a building under construction gets the ventilation its maker calls for, and someone checks the air. A CO alarm warns you; it does not make it acceptable to run a generator in the next room.

Know the signs: headache, dizziness, nausea, tiredness, confusion. It can leave you too confused to see what is happening, so watch each other.

If you or someone near you has those signs, shut off the equipment if you can do it on your way out, get everyone to fresh air and call 911. Do not go back in after someone if you would have to breathe that air: rescuers get overcome too. That rescue belongs to people trained and equipped for it.

A dust mask does nothing against CO; it stops particles, not gases. If the air shows CO and the work has to go on, the air gets fixed first: the engine comes out, the ventilation goes in, and the space is tested again before anyone goes back.

Three questions for the crew

  1. Which engines or heaters will run today, and where does their exhaust go?
    Listen for: Each machine by name and a spot outside, away from doors, windows and air intakes, or an electric or battery tool instead.
  2. What do you do if two people in the same room get headaches and feel dizzy?
    Listen for: Everyone out to fresh air, equipment off on the way out if it is safe, a call to 911, and nobody back in until the air has been tested.
  3. Why does an open door not make a generator safe inside?
    Listen for: CO can build up quickly in enclosed and partly enclosed spaces, open door or not, and nobody can smell it.

What are the limits for carbon monoxide?

OSHA's permissible exposure limit for carbon monoxide is 50 parts per million as an 8-hour time-weighted average, in construction (29 CFR 1926.55, Table 1) and in general industry (29 CFR 1910.1000, Table Z-1). It limits a worker's exposure over a shift. It is not the alarm setting of a detector, and it is not a safe level for an emergency.

NIOSH, the federal research agency, recommends a lower limit: 35 ppm averaged over the workday and a ceiling of 200 ppm, with 1,200 ppm as the level immediately dangerous to life or health. Those are NIOSH recommendations, not OSHA rules.

In construction, when temporary heating devices are used, fresh air shall be supplied in sufficient quantities to maintain the health and safety of workers, and where natural means of fresh air supply are inadequate, mechanical ventilation shall be provided (29 CFR 1926.154(a)(1)).

Where a space meets the definition of a permit-required confined space, conditions in it are tested before entry is authorized (29 CFR 1926.1204(e)(1) in construction, 29 CFR 1910.146(d)(5)(i) in general industry).

The paragraphs, word for word:

“(a) Ventilation. (1) Fresh air shall be supplied in sufficient quantities to maintain the health and safety of workmen. Where natural means of fresh air supply is inadequate, mechanical ventilation shall be provided.”

29 CFR 1926.154(a)(1)

Where CO builds up on a job, and what to do

SourceWhere it gets dangerousPreventionIf someone feels sick
Portable generatorInside a building, garage, basement or trailer, or near a door, window or air intakeRun it outside, away from openings, with the exhaust pointed awayEquipment off on the way out if safe, everyone to fresh air, call 911
Fuel-burning heaterA closed-in floor, a tented area, a trailerThe ventilation its maker calls for, an electric heater where possible, the air checkedSame: out, fresh air, 911
Gas saw, pressure washer or compressorInside a building or a partly enclosed areaThe engine stays outside and only the hose or line comes in; electric or battery tools insideSame: out, fresh air, 911
Forklift or truck engineA warehouse with the doors closed, a dock with trucks idlingEngines off when parked, ventilation, electric equipment indoorsSame: out, fresh air, 911
Confined spaceA space where exhaust or a process gas collectsThe air tested before entry; nothing with an engine insideRescue only by people trained and equipped for it

A CO alarm or a personal monitor warns that the air is already contaminated. It does not make running an engine indoors acceptable.

Drill: where does the exhaust go?

About five minutes, before anyone starts an engine or a heater.

  1. Walk to each generator, heater, saw or compressor planned for the day.
  2. Point to where its exhaust goes, and to the doors, windows and air intakes nearby.
  3. Move anything that would send exhaust inside, or switch to an electric or battery tool.
  4. Check the CO alarm or personal monitor the way its maker says, if the site uses one.
  5. Agree on the call: who calls 911, and where everyone meets outside.

Inside HazComFast

Give the CO talk before the heaters come out

Print this talk for the morning meeting. In HazComFast, the crew signs the toolbox talk on a phone, in English or Spanish, and the record stays with each worker.

  • Signed where the signal isn't

    In a basement or a dead zone, the crew can still sign the toolbox talk in Chrome on Android or on a computer. The sign-ins go out once the app is open with a signal again, and each one lands once.
  • Sheets and certificates in Spanish

    Toolbox talk PDFs and training certificates print in Spanish, and compliance reports come out in English, Spanish or both side by side.
  • Thirty hires on a Monday morning

    Import a spreadsheet, see line by line who was created and who wasn't, and print one sheet of QR badges for the morning toolbox talk. Email is optional.
  • Records that stay when a worker leaves

    When a worker leaves, their training records and competent person designation stay on file. The account can't take them along.

New sign-ups are paused · the free tools need no account

Questions about this talk

What is OSHA's limit for carbon monoxide?

50 parts per million as an 8-hour time-weighted average, in construction (29 CFR 1926.55, Table 1) and in general industry (29 CFR 1910.1000, Table Z-1).

Can you run a generator inside a building with the doors open?

NIOSH advises against running gasoline engines or tools inside buildings or in partly enclosed areas, where CO can build up quickly, and recommends placing gasoline engines outside, 20 feet or more from any window, door or other opening.

Does a dust mask protect against carbon monoxide?

No. A dust mask stops particles, not gases. OSHA's carbon monoxide fact sheet points to a self-contained breathing apparatus or a supplied-air respirator where concentrations are high, and to canister respirators with personal CO monitoring only for short periods where levels are not high, within a respiratory protection program (29 CFR 1910.134).

What should you do if a coworker shows signs of CO poisoning?

Get them and everyone else to fresh air, shut off the equipment if you can do it on the way out, and call 911. Do not go back into the space if you would breathe the same air: OSHA's fact sheet warns that rescuers can be exposed to fatal levels, and that rescue is for people trained and equipped for it.

Is a CO detector enough on a jobsite?

A detector or a personal monitor with an audible alarm warns people when CO is already in the air, and both NIOSH and OSHA recommend them where exposure is possible. It does not replace keeping engines and their exhaust out of enclosed and partly enclosed spaces.

Does OSHA require toolbox talks?

No rule requires a talk by that name. Construction employers must instruct each employee in the recognition and avoidance of unsafe conditions (29 CFR 1926.21(b)(2)), and many standards carry their own training duty; a toolbox talk is a common way to deliver part of it.

Do we need a sign-in sheet for a toolbox talk?

No general OSHA rule requires attendance records for a toolbox talk. Some standards require written certification of training, such as fall protection (29 CFR 1926.503(b)(1)) and forklift operators (29 CFR 1910.178(l)(6)). A signed sheet shows who attended; keep the topic, the date, the presenter and the language with it. It does not show that the content was understood.

Go further

More talks on chemicals, dust and noise

Sources

In a State Plan state, the state's own standard applies, and it can be stricter than the federal rule. Not legal advice.

All safety topics 100 safety topics Safety tip of the day