At a glance
- Carbon monoxide: permissible exposure limit of 50 ppm, 8-hour time-weighted average, in construction (29 CFR 1926.55, Table 1) and general industry (29 CFR 1910.1000, Table Z-1).
- About 5 minutes to read the script out loud, then the three questions. The drill and the tables below add time if you use them.
- Free PDF and Word file: the script, the questions, the rule and a 20-line sign-in sheet. No account, no email.
Read this to your crew
Today is carbon monoxide, CO. It comes out of anything that burns fuel: generators, propane and kerosene heaters, gas-powered saws, pressure washers, compressors, forklifts and trucks idling by a door. You cannot see it, smell it or taste it, and it can reach a deadly level in minutes in a room, a basement, a trailer or a tented area.
Engines run outside, away from doors, windows and air intakes, so the exhaust does not drift back in. An open door or a fan does not make an engine safe inside: CO can build up quickly in enclosed and partly enclosed spaces. When the work is inside, we use electric, battery or air-powered tools if they can be used safely.
Heaters are the winter version of the same problem. A fuel-burning heater inside a building under construction gets the ventilation its maker calls for, and someone checks the air. A CO alarm warns you; it does not make it acceptable to run a generator in the next room.
Know the signs: headache, dizziness, nausea, tiredness, confusion. It can leave you too confused to see what is happening, so watch each other.
If you or someone near you has those signs, shut off the equipment if you can do it on your way out, get everyone to fresh air and call 911. Do not go back in after someone if you would have to breathe that air: rescuers get overcome too. That rescue belongs to people trained and equipped for it.
A dust mask does nothing against CO; it stops particles, not gases. If the air shows CO and the work has to go on, the air gets fixed first: the engine comes out, the ventilation goes in, and the space is tested again before anyone goes back.
Three questions for the crew
- Which engines or heaters will run today, and where does their exhaust go?
Listen for: Each machine by name and a spot outside, away from doors, windows and air intakes, or an electric or battery tool instead. - What do you do if two people in the same room get headaches and feel dizzy?
Listen for: Everyone out to fresh air, equipment off on the way out if it is safe, a call to 911, and nobody back in until the air has been tested. - Why does an open door not make a generator safe inside?
Listen for: CO can build up quickly in enclosed and partly enclosed spaces, open door or not, and nobody can smell it.
What are the limits for carbon monoxide?
OSHA's permissible exposure limit for carbon monoxide is 50 parts per million as an 8-hour time-weighted average, in construction (29 CFR 1926.55, Table 1) and in general industry (29 CFR 1910.1000, Table Z-1). It limits a worker's exposure over a shift. It is not the alarm setting of a detector, and it is not a safe level for an emergency.
NIOSH, the federal research agency, recommends a lower limit: 35 ppm averaged over the workday and a ceiling of 200 ppm, with 1,200 ppm as the level immediately dangerous to life or health. Those are NIOSH recommendations, not OSHA rules.
In construction, when temporary heating devices are used, fresh air shall be supplied in sufficient quantities to maintain the health and safety of workers, and where natural means of fresh air supply are inadequate, mechanical ventilation shall be provided (29 CFR 1926.154(a)(1)).
Where a space meets the definition of a permit-required confined space, conditions in it are tested before entry is authorized (29 CFR 1926.1204(e)(1) in construction, 29 CFR 1910.146(d)(5)(i) in general industry).
The paragraphs, word for word:
“(a) Ventilation. (1) Fresh air shall be supplied in sufficient quantities to maintain the health and safety of workmen. Where natural means of fresh air supply is inadequate, mechanical ventilation shall be provided.”
Where CO builds up on a job, and what to do
| Source | Where it gets dangerous | Prevention | If someone feels sick |
|---|---|---|---|
| Portable generator | Inside a building, garage, basement or trailer, or near a door, window or air intake | Run it outside, away from openings, with the exhaust pointed away | Equipment off on the way out if safe, everyone to fresh air, call 911 |
| Fuel-burning heater | A closed-in floor, a tented area, a trailer | The ventilation its maker calls for, an electric heater where possible, the air checked | Same: out, fresh air, 911 |
| Gas saw, pressure washer or compressor | Inside a building or a partly enclosed area | The engine stays outside and only the hose or line comes in; electric or battery tools inside | Same: out, fresh air, 911 |
| Forklift or truck engine | A warehouse with the doors closed, a dock with trucks idling | Engines off when parked, ventilation, electric equipment indoors | Same: out, fresh air, 911 |
| Confined space | A space where exhaust or a process gas collects | The air tested before entry; nothing with an engine inside | Rescue only by people trained and equipped for it |
A CO alarm or a personal monitor warns that the air is already contaminated. It does not make running an engine indoors acceptable.
Drill: where does the exhaust go?
About five minutes, before anyone starts an engine or a heater.
- Walk to each generator, heater, saw or compressor planned for the day.
- Point to where its exhaust goes, and to the doors, windows and air intakes nearby.
- Move anything that would send exhaust inside, or switch to an electric or battery tool.
- Check the CO alarm or personal monitor the way its maker says, if the site uses one.
- Agree on the call: who calls 911, and where everyone meets outside.