In Wyoming, a serious violation of 29 CFR 1926.1053 (Ladders (Construction)) carries a maximum penalty of $16,550 per violation in 2026, rising to $165,514 for a willful or repeat violation. Ladders (Construction) is enforced for private construction employers by Wyoming OSHA.
- Home
- OSHA Penalties by State
- Wyoming
- Ladders (Construction)
29 CFR 1926.1053 · Wyoming
Ladders (Construction) Requirements in Wyoming
Ladders (Construction) in Wyoming: 2026 penalties, who enforces 29 CFR 1926.1053, the paragraphs cited and free tools.
Verified vs OSHA sources · 2026-10-19
In FY2025, Wyoming OSHA cited 29 CFR 1926.1053 1 time in Wyoming construction (1.1% of its construction citations there, the 25th most-cited standard there). The paragraph cited most was 1926.1053(b)(1) with 1 citation.
1
1926.1053 citations in Wyoming construction, FY2025
(b)(1)
paragraph cited most in Wyoming (1 citation)
27.1
fatal work injuries per 100,000 full-time workers in construction, Wyoming, 2024 (BLS)
Wyoming 29 CFR 1926.1053 Enforcement, FY2025
Verified · 2026-08-081
citations of 29 CFR 1926.1053 (FY2025)
$3,111
penalties for this standard
1.1%
of the state's 89 construction citations
In FY2025, Wyoming OSHA cited 29 CFR 1926.1053 (Ladders (Construction)) 1 times on Wyoming construction jobsites with $3,111 in penalties for it (current amounts), about 1.1% of every construction citation the state issued that year. That put it 25th on Wyoming's most-cited construction list for FY2025.
Ladders (Construction) in Wyoming: real citations and FY2025 totals
Counted · Oct 21, 2026The latest 6 inspections in Wyoming with an item under 29 CFR 1926.1053 in the Department of Labor's OSHA enforcement data, every industry, newest first. Each line shows the item of that inspection with the largest current penalty under 29 CFR 1926.1053.
Aug 3, 2026 · An employer in foundation, structure, and building exterior contractors in Cheyenne
1926.1053(b)(1), serious, $4,965 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by the State Plan's office.
Inspection activity number 349008383 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.
Mar 25, 2026 · SHAFFER'S COMPLETE CONSTRUCTION in Sheridan
1926.1053(b)(4), other-than-serious, $0 current penalty ($2,713 as first proposed). Case closed Apr 17, 2026. Recorded by the State Plan's office.
Inspection activity number 348745639 in the Department of Labor data; industry: Nonresidential Building Construction.
Mar 25, 2026 · MCCARTY AND COMPANY CONSTRUCTION LLC in Sheridan
1926.1053(b)(4), other-than-serious, $2,170 current penalty ($2,713 as first proposed). Case closed Jun 2, 2026. Recorded by the State Plan's office.
Inspection activity number 348745118 in the Department of Labor data; industry: Other Specialty Trade Contractors.
Feb 25, 2026 · An employer in foundation, structure, and building exterior contractors in Cheyenne
1926.1053(b)(1), serious, $3,192 penalty; 2 items under 29 CFR 1926.1053 in this inspection, $3,192 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by the State Plan's office.
Inspection activity number 348598368 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.
Nov 17, 2025 · JJ CORONA BUILDERS in Etna
1926.1053(b)(8), serious, $3,457 penalty; 2 items under 29 CFR 1926.1053 in this inspection, $3,457 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by the State Plan's office.
Inspection activity number 348510546 in the Department of Labor data; industry: Nonresidential Building Construction.
Sep 18, 2025 · MONOS CONSTRUCTION LLC in Sheridan
1926.1053(b)(1), serious, $3,111 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by the State Plan's office.
Inspection activity number 348465931 in the Department of Labor data; industry: Nonresidential Building Construction.
FY2025 in Wyoming, every industry
1
citation items under 29 CFR 1926.1053 in 1 inspection
0
items at employers outside construction (1 at construction employers, NAICS 23)
0.0%
of the 4,009 items under 29 CFR 1926.1053 in the data
From Oct 1, 2024 to Sep 30, 2025, the data record 1 citation item under 29 CFR 1926.1053 at inspected sites in Wyoming, in 1 inspection, every industry included. Of the 45 sections of 29 CFR parts 1904, 1910 and 1926 cited in Wyoming that year (203 citation items in all), 30 drew more items than 29 CFR 1926.1053 and 14 drew as many. By classification: 1 serious, 0 willful, 0 repeat and 0 other-than-serious. All of them were recorded by the State Plan's office. Of the 53 states, DC and territories with items under 29 CFR 1926.1053 in this data, 50 had more than Wyoming and 2 had as many.
| Paragraph | Items | Share of the 1 |
|---|---|---|
| 1926.1053(b)(1) | 1 | 100% |
Industry groups with the most items: Nonresidential Building Construction (1). 100% of the 1 inspection with a recorded headcount were at sites with 1 to 10 employees (the headcount of the inspected site, not of the employer).
Quarter by quarter in Wyoming
| Quarter | Items |
|---|---|
| FY2025 · Oct to Dec 2024 | 0 |
| FY2025 · Jan to Mar 2025 | 0 |
| FY2025 · Apr to Jun 2025 | 0 |
| FY2025 · Jul to Sep 2025 | 1 |
| FY2026 · Oct to Dec 2025 | 2 |
| FY2026 · Jan to Mar 2026 | 4 |
| FY2026 · Apr to Jun 2026 | 0 |
| FY2026 · Jul to Sep 2026 | 1 |
FY2026 so far: 7 citation items, against 1 in FY2025. FY2026 is still incomplete in the data extracted Oct 21, 2026: the Department of Labor adds citations with a delay.
29 CFR 1926.1053 in the states next to Wyoming
Since October 1, 2024, the data record 8 citation items under 29 CFR 1926.1053 in Wyoming; in the states next to it, Colorado 86 (60 in FY2025), Idaho 75 (49 in FY2025), Nebraska 67 (55 in FY2025), South Dakota 48 (25 in FY2025), Utah 28 (13 in FY2025) and Montana 5 (4 in FY2025). The latest there:
Sep 8, 2026 · MARTINEZ ROOFING, LLC in Billings, Montana
1926.1053(b)(1), serious, $1,447 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.
Inspection activity number 349066522 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.
Sep 8, 2026 · FORTRESS FRAMING, INC. in Thornton, Colorado
1926.1053(b)(1), serious, $3,405 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.
Inspection activity number 349039834 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.
Sep 8, 2026 · GUERRERO BRO. CONSTRUCTION LLC in Sioux Falls, South Dakota
1926.1053(b)(1), serious, $1,362 current penalty ($2,270 as first proposed); 2 items under 29 CFR 1926.1053 in this inspection, $1,362 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.
Inspection activity number 348890492 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.
From the Department of Labor's OSHA enforcement data, extracted Oct 21, 2026: deleted items left out, 29 CFR numbers only, placed in the state of the inspected site; establishment names as recorded, shown when they name a business or a public body; penalties as recorded on Oct 28, 2026, and they change when a case is settled or contested. A State Plan office can record an item under a state rule number instead of 29 CFR 1926.1053; only items recorded under the federal number appear here. These are not figures OSHA publishes for the state, and the live database can change them. Same data source and method as our HazCom enforcement study.
What Wyoming's own rule says
“29 C.F.R. §§ 1926.1050 - 1926.1060 (2016) as it was in effect on June 19, 2018.”
Ladders and stairways share Chapter 24, which carries the whole of Subpart X, 1926.1050 through 1926.1060, at the 2016 edition as in effect June 19, 2018. The three-foot extension above the landing, the load ratings and the training duties are unchanged. Wyoming's construction rules also carry chapters for general provisions and general interpretations, Chapters 1 and 2, each with its own incorporation date.
Wyo. OSHA Construction 1926, Chapter 24 (Subpart X)The duty matches the federal text. Only the citation number differs.
Falls and work deaths in Wyoming, 2024
Wyoming recorded 37 fatal work injuries in 2024, down from 45 in 2023. Falls, slips and trips caused 5 of them (14%). Construction accounted for 6.
Source: BLS Census of Fatal Occupational Injuries, Wyoming, 2024
How Wyoming Enforces 29 CFR 1926.1053
Wyoming runs an OSHA-approved State Plan administered by Wyoming OSHA, which ordinarily covers private-sector construction (a few workplaces, such as some federal enclaves, military installations and maritime work, stay under federal OSHA, as the Coverage section of OSHA's page on the plan lists). Its compliance officers enforce Wyoming's own standards, which must be at least as effective as federal OSHA's and may go further. On this subject the rule is Wyo. OSHA Construction 1926, Chapter 24 (Subpart X). Wyoming OSHA cited 29 CFR 1926.1053 1 time in Wyoming construction in FY2025 (OSHA Frequently Cited Standards). Wyoming applies the federal penalty maximums.
In Wyoming, the FY2025 citations under 29 CFR 1926.1053 went most often to Commercial and Institutional Building Construction (1). Citing instances separately is a discretionary exception: OSHA's instance-by-instance policy of April 17, 2024 allows it for serious or repeat violations, and other-than-serious recordkeeping violations, where the standard's text allows it.
HazComFast records the state of every jobsite and shows that the Wyoming State Plan ordinarily governs it; a location in the state does not settle the exclusions listed in the Coverage section of OSHA's page on the plan. Start free
Help and oversight in Wyoming
Free, confidential help: OSHA On-Site Consultation
In Wyoming, the program is OSHA Division (Wyoming Department of Workforce Services). OSHA describes it as “Primarily for smaller businesses, no-cost, confidential consultations help employers identify and address hazards and establish or improve safety and health programs.” It is separate from OSHA enforcement; the employer commits to correcting serious hazards.
Sources: osha.gov and the state's official statute site, September 26, 2026.
Wyoming Penalty Amounts for 29 CFR 1926.1053 (2026)
Reviewed · 2026-10-19Federal amounts effective January 15, 2025 (29 CFR 1903.15(d)).
| Violation type | 2026 maximum | Basis |
|---|---|---|
| Serious | $16,550 | Federal max · 29 CFR 1903.15(d) |
| Willful | $165,514 | Federal max · 29 CFR 1903.15(d) |
| Repeat | $165,514 | Federal max · 29 CFR 1903.15(d) |
| Failure to abate | $16,550/day | up to $16,550 per day; the total is normally capped at 30 times the daily amount (FOM Ch.6) |
Wyoming applies the federal OSHA maximums. Amounts are ceilings per violation. Wyoming OSHA computes proposed penalties under its own State Plan procedures.
Key Ladders (Construction) Requirements 29 CFR 1926.1053
- Give a portable ladder used to reach an upper landing surface side rails that extend at least 3 feet above it; where the ladder's length makes that impossible, secure it at the top to a rigid support that will not deflect and provide a grasping device (1926.1053(b)(1))
- Use ladders only on stable and level surfaces unless they are secured to prevent accidental displacement; do not use them on slippery surfaces unless secured or fitted with slip-resistant feet; secure a ladder placed where work or traffic can displace it, or barricade it (1926.1053(b)(6)-(8))
- Place a non-self-supporting ladder at the angle the rule sets, about one-quarter of the working length from the base, except for the site-built wooden ladder cases it lists (1926.1053(b)(5))
- Have a competent person inspect ladders for visible defects on a periodic basis and after any occurrence that could affect their safe use; mark or tag a defective portable ladder "Do Not Use" and withdraw it until repaired (1926.1053(b)(15)-(16))
- Do not load a ladder beyond its maximum intended load (1926.1053(a)(1)) and do not use the top or top step of a stepladder as a step (1926.1053(b)(13))
- Each employee faces the ladder when climbing, uses at least one hand to grasp it, and carries no object or load that could cause a loss of balance (1926.1053(b)(20)-(22))
Who enforces it in Wyoming: Wyoming OSHA inspects private employers, construction included, under an OSHA-approved State Plan. Wyoming's own rule on this subject is Wyo. OSHA Construction 1926, Chapter 24 (Subpart X).
The compliance checklist, the paragraphs OSHA cites nationally and what an inspector checks under 29 CFR 1926.1053 are on the 29 CFR 1926.1053 page.
Most-Cited Ladders (Construction) Paragraphs in Wyoming, FY2025
Wyoming OSHA issued 1 citation under 29 CFR 1926.1053 to Wyoming construction employers in FY2025. The paragraphs cited most, with the official text. A serious violation carries up to $16,550.
- 1
1926.1053(b)(1) 1 citation
“When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing …”
HazComFast count from the Labor Department's OSHA enforcement data: citations issued in FY2025 to construction employers (NAICS 23), by the paragraph cited. Paragraph text: eCFR, current as of September 24, 2026. data.dol.gov
Wyoming Safety & Enforcement Profile
89
FY2025 construction citations
Wyoming OSHA
Enforces private construction
- Construction trades inspected most in Wyoming, FY2025: Roofing Contractors (17), Commercial and Institutional Building Construction (15) and New Single-Family Housing Construction (except For-Sale Builders) (5), out of 73 inspections opened (federal OSHA and State Plan combined).
- Cited most under 29 CFR 1926.1053 in Wyoming, FY2025: Commercial and Institutional Building Construction (1), of 1 citations.
- Construction fatality rate in Wyoming, 2024: 27.1 per 100,000 full-time workers, 2nd highest of the 40 states BLS published (all industries: 13.9).
HazComFast count from the Labor Department's OSHA enforcement data: inspections of construction employers (NAICS 23) opened from October 1, 2024 to September 30, 2025, federal OSHA and State Plan combined, grouped by the inspected employer's 2022 NAICS industry. HazComFast count from the Labor Department's OSHA enforcement data: citations issued in FY2025 to construction employers (NAICS 23), grouped by the cited employer's 2022 NAICS industry. Industry names are the Census Bureau's 2022 NAICS titles. data.dol.gov · BLS fatality rates by state, 2024
Free Ladders (Construction) Compliance Tools
Ladders (Construction) FAQ for Wyoming
Which Wyoming construction trades are cited most under Ladders (Construction)?
In FY2025, Wyoming OSHA issued 1 citations under 29 CFR 1926.1053 to Wyoming construction employers, most often to Commercial and Institutional Building Construction (1) (HazComFast count from Labor Department enforcement data, by the cited employer's NAICS industry). Wyoming OSHA inspects these employers directly and may apply requirements beyond the federal standard. For context, Wyoming OSHA issued 89 construction citations across 37 inspections in FY2025. On a jobsite, the standard on this subject is 29 CFR 1926.1053.
How often is Ladders (Construction) cited on Wyoming jobsites?
In FY2025, Wyoming's state plan (Wyoming OSHA) issued 89 construction citations across 37 inspections (OSHA Frequently Cited Standards, NAICS 23). Wyoming's fatality figures are shown above.
Who enforces ladder rules (1926.1053) on Wyoming construction sites?
Wyoming OSHA, a division of the Wyoming Department of Workforce Services. Wyoming runs a full OSHA-approved State Plan, so a state compliance officer inspects and cites 29 CFR 1926.1053 on private jobsites.
Can I get free OSHA help in Wyoming without an inspection?
Yes. OSHA's On-Site Consultation Program in Wyoming is OSHA Division (Wyoming Department of Workforce Services). OSHA describes it this way: "Primarily for smaller businesses, no-cost, confidential consultations help employers identify and address hazards and establish or improve safety and health programs." Consultations are separate from OSHA enforcement, and the employer commits to correcting serious hazards.
How often does Wyoming cite 29 CFR 1926.1053 in construction?
In FY2025, Wyoming OSHA cited 29 CFR 1926.1053 (Ladders (Construction)) 1 times on Wyoming construction jobsites, with $3,111 in penalties for that standard alone (current amounts), about 1.1% of the 89 construction citations the state issued that year. (Source: OSHA Frequently Cited Standards, NAICS 23; verified 2026-08-08.)
Ladders (Construction) Guides & Resources
Compare this combination against any other state and standard with the enforcement risk lookup.
Ladders (Construction) in Other States
7 other state plans write a rule of their own for 29 CFR 1926.1053 rather than adopting the federal text unchanged. Those are listed first. Compare all of them side by side.
Other OSHA Standards in Wyoming
Sources & verification
Penalty amounts and plan-type data were checked on 2026-10-19 against eCFR, OSHA.gov, and the Federal Register. This page is informational and not legal advice; consult the enforcing agency or counsel for your specific situation.
- https://www.osha.gov/memos/2026-05-21/2026-annual-adjustments-osha-civil-penalties
- https://www.osha.gov/memos/2024-04-17/instance-instance-citation-policy-serious-repeat-and-other-serious-violations
- https://www.osha.gov/penalties
- https://www.osha.gov/fom/chapter-6
- Wyoming OSHA: https://dws.wyo.gov/dws-division/osha/
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.