Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

29 CFR 1926.451 · Florida

Scaffolding Requirements in Florida

Scaffolding in Florida: 2026 penalties, who enforces 29 CFR 1926.451, the paragraphs cited and free tools.

Verified vs OSHA sources · 2026-10-19

FloridaConstruction (29 CFR 1926)Federal OSHA Jurisdiction

In Florida, a serious violation of 29 CFR 1926.451 (Scaffolding) carries a maximum penalty of $16,550 per violation in 2026, rising to $165,514 for a willful or repeat violation. Scaffolding is enforced for private construction employers by federal OSHA.

In FY2025, federal OSHA cited 29 CFR 1926.451 232 times in Florida construction (9.7% of its construction citations there, the 4th most-cited standard there). The paragraph cited most was 1926.451(g)(1) with 39 citations.

232

1926.451 citations in Florida construction, FY2025

(g)(1)

paragraph cited most in Florida (39 citations)

9.4

fatal work injuries per 100,000 full-time workers in construction, Florida, 2024 (BLS)

Federal OSHA in Florida: 29 CFR 1926.451, FY2025

Counted · 2026-09-26

232

citations of 29 CFR 1926.451 in 92 inspections

$761,344

penalties, current amounts ($986,395 as first proposed)

9.7%

of the 2,403 federal construction citations in Florida

In FY2025, federal OSHA cited 29 CFR 1926.451 (Scaffolding) 232 times in inspections of Florida construction employers. It ranked fourth of the 86 standards cited in them. By classification: 207 serious, 2 repeat, 2 willful, 21 other-than-serious. Most-cited paragraphs: 1926.451(g)(1) (39), 1926.451(b)(1) (37), 1926.451(e)(1) (30).

Counted by HazComFast from the U.S. Department of Labor's OSHA enforcement data (inspection and violation tables, retrieved September 26, 2026): citations issued October 1, 2024 – September 30, 2025 on federal OSHA inspections of construction employers (NAICS 23) in the state, deleted citations excluded, penalties at current amounts. OSHA's own cited-standards tool does not break federal states out; summed over every state, this count matches it within a few citations (6,778 for 1926.501, against 6,772). data.dol.gov

Scaffolding in Florida: real citations and FY2025 totals

Counted · Oct 21, 2026

The latest 10 inspections in Florida with an item under 29 CFR 1926.451 in the Department of Labor's OSHA enforcement data, every industry, newest first. Each line shows the item of that inspection with the largest current penalty under 29 CFR 1926.451.

  • Sep 1, 2026 · CAZU CONSTRUCTION SERVICES INC in Lake Mary

    1926.451(b)(1), serious, $3,405 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348973728 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 31, 2026 · M.R. GALARZA INC. in Palm City

    1926.451(c)(2)(iv), serious, $1,362 current penalty ($2,270 as first proposed). Case closed Sep 11, 2026. Recorded by federal OSHA.

    Inspection activity number 348828211 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 26, 2026 · RYAN HAMMOND, INC. in Fort Myers Beach

    1926.451(g)(1), serious, $7,414 current penalty ($9,268 as first proposed); 2 items under 29 CFR 1926.451 in this inspection, $10,725 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348816992 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 19, 2026 · U.S. STRUCTURES, INC. in Boynton Beach

    1926.451(b)(1), serious, $3,689 current penalty ($6,149 as first proposed); 2 items under 29 CFR 1926.451 in this inspection, $7,378 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348784125 in the Department of Labor data; industry: Business, Professional, Labor, Political, and Similar Organizations.

  • Aug 17, 2026 · GOLDEN BEAM GROUP, INC. in Inlet Beach

    1926.451(b)(2), serious, $3,405 penalty; 3 items under 29 CFR 1926.451 in this inspection, $3,405 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349093716 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 17, 2026 · AMBROSE DESIGN INC. in Belleair Beach

    1926.451(g)(1), serious, $2,979 current penalty ($3,972 as first proposed). Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348983750 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 3, 2026 · NORTH FLORIDA DRYWALL & PAINTING LLC in Lake Mary

    1926.451(c)(2)(i), serious, $3,972 penalty; 5 items under 29 CFR 1926.451 in this inspection, $15,888 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348879800 in the Department of Labor data; industry: Nonresidential Building Construction.

  • Jul 22, 2026 · NEXFORM CONSTRUCTION INC in Apopka

    1926.451(b)(1), serious, $3,972 penalty; 6 items under 29 CFR 1926.451 in this inspection, $11,916 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348895459 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Jul 15, 2026 · JMF CONSTRUCTION SERVICES INC in Coral Gables

    1926.451(g)(4)(iii), serious, $2,837 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348711425 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Jul 14, 2026 · SL CONCRETE OF SWF, LLC in Redington Beach

    1926.451(c)(2), serious, $2,838 penalty; 2 items under 29 CFR 1926.451 in this inspection, $5,676 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 348696774 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

FY2025 in Florida, every industry

238

citation items under 29 CFR 1926.451 in 97 inspections

6

items at employers outside construction (232 at construction employers, NAICS 23)

7.4%

of the 3,222 items under 29 CFR 1926.451 in the data

From Oct 1, 2024 to Sep 30, 2025, the data record 238 citation items under 29 CFR 1926.451 at inspected sites in Florida, in 97 inspections, every industry included. Of the 137 sections of 29 CFR parts 1904, 1910 and 1926 cited in Florida that year (3,813 citation items in all), 3 drew more items than 29 CFR 1926.451. By classification: 211 serious, 2 willful, 2 repeat and 23 other-than-serious. All of them were recorded by federal OSHA offices. Of the 55 states, DC and territories with items under 29 CFR 1926.451 in this data, 1 had more than Florida.

Paragraphs cited in Florida, FY2025
ParagraphItemsShare of the 238
1926.451(g)(1)3916%
1926.451(b)(1)3816%
1926.451(e)(1)3013%
1926.451(c)(2)208%
1926.451(f)(3)146%

38 different paragraphs were cited in all; the table lists the 5 with the most items.

Industry groups with the most items: Foundation, Structure, and Building Exterior Contractors (131); Building Finishing Contractors (38); Residential Building Construction (38). 85% of the 97 inspections with a recorded headcount were at sites with 1 to 10 employees (the headcount of the inspected site, not of the employer).

Quarter by quarter in Florida

Citation items under 29 CFR 1926.451 at inspected sites in Florida, by quarter of issuance
QuarterItems
FY2025 · Oct to Dec 202433
FY2025 · Jan to Mar 202552
FY2025 · Apr to Jun 202583
FY2025 · Jul to Sep 202570
FY2026 · Oct to Dec 202536
FY2026 · Jan to Mar 202656
FY2026 · Apr to Jun 202643
FY2026 · Jul to Sep 202637

FY2026 so far: 172 citation items, against 238 in FY2025. FY2026 is still incomplete in the data extracted Oct 21, 2026: the Department of Labor adds citations with a delay.

29 CFR 1926.451 in the states next to Florida

Since October 1, 2024, the data record 410 citation items under 29 CFR 1926.451 in Florida; in the states next to it, Georgia 254 (122 in FY2025) and Alabama 120 (64 in FY2025). The latest there:

  • Sep 1, 2026 · An employer in foundation, structure, and building exterior contractors in Fairhope, Alabama

    1926.451(g)(1), serious, $2,838 penalty. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349131680 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

  • Aug 17, 2026 · SEALY CONSTRUCTION COMPANY, LLC in Calera, Alabama

    1926.451(c)(2)(i), serious, $9,268 penalty; 4 items under 29 CFR 1926.451 in this inspection, $35,749 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349007633 in the Department of Labor data; industry: Residential Building Construction.

  • Aug 12, 2026 · SANCHEZ CONSTRUCTION in Calera, Alabama

    1926.451(c)(2)(i), serious, $2,383 current penalty ($3,972 as first proposed); 5 items under 29 CFR 1926.451 in this inspection, $11,575 in current penalties for all of them. Case still open in the data extracted Oct 21, 2026. Recorded by federal OSHA.

    Inspection activity number 349007674 in the Department of Labor data; industry: Foundation, Structure, and Building Exterior Contractors.

From the Department of Labor's OSHA enforcement data, extracted Oct 21, 2026: deleted items left out, 29 CFR numbers only, placed in the state of the inspected site; establishment names as recorded, shown when they name a business or a public body; penalties as recorded on Oct 28, 2026, and they change when a case is settled or contested. These are not figures OSHA publishes for the state, and the live database can change them. Same data source and method as our HazCom enforcement study.

Scaffolding Cases in Florida

Stucco Works Inc.

$74,555 proposed - $40,000 final

Miami Beach, Florida · 2023

In July 2023, a 22-year-old worker suffered a fatal head injury at a Miami Beach residential site when the hoist arm of a scaffold pulley system detached and struck him as crews hoisted buckets of concrete. OSHA cited the contractor for using unsafe scaffolding, exposing workers to struck-by hazards and falls of up to 27 feet, and failing to train scaffold users, and proposed $74,555. (The company contested the findings; an administrative law judge's decision reduced the penalty from $74,555 to $40,000, and the inspection record shows the case closed on May 12, 2025.)

OSHA inspection 1683379.015 (Fat/Cat), case closed - OSHA Establishment Search

How Florida Enforces 29 CFR 1926.451

Florida has no State Plan, so federal OSHA has jurisdiction. 29 CFR 1926.451 is enforced by U.S. Department of Labor compliance officers using standard federal procedures and the federal penalty maximums.

In Florida, the FY2025 citations under 29 CFR 1926.451 went most often to Masonry Contractors (50) and Siding Contractors (38). Citing instances separately is a discretionary exception: OSHA's instance-by-instance policy of April 17, 2024 allows it for serious or repeat violations, and other-than-serious recordkeeping violations, where the standard's text allows it.

Help and oversight in Florida

Free, confidential help: OSHA On-Site Consultation

In Florida, the program is USF SafetyFlorida Consultation Program (University of South Florida). OSHA describes it as “Primarily for smaller businesses, no-cost, confidential consultations help employers identify and address hazards and establish or improve safety and health programs.” It is separate from OSHA enforcement; the employer commits to correcting serious hazards.

Florida consultation program · OSHA consultation directory

Who inspects private employers here

Federal OSHA, from the Fort Lauderdale Area Office (Ft. Lauderdale), the Jacksonville Area Office (Jacksonville), the Tampa Area Office (Tampa), the Mobile Area Office (Mobile) and the Orlando Area Office (Orlando).

OSHA offices for Florida

Sources: osha.gov and the state's official statute site, September 26, 2026.

Florida Penalty Amounts for 29 CFR 1926.451 (2026)

Reviewed · 2026-10-19

Federal amounts effective January 15, 2025 (29 CFR 1903.15(d)).

Violation type2026 maximumBasis
Serious$16,550Federal max · 29 CFR 1903.15(d)
Willful$165,514Federal max · 29 CFR 1903.15(d)
Repeat$165,514Federal max · 29 CFR 1903.15(d)
Failure to abate$16,550/dayup to $16,550 per day; the total is normally capped at 30 times the daily amount (FOM Ch.6)

Florida applies the federal OSHA maximums. Amounts are ceilings per violation. Federal OSHA can reduce the proposed penalty for employer size, good faith and history, depending on the violation class and the facts (FOM CPL 02-00-164 Ch. 6). There was no inflation increase for 2026: the 2025 amounts remain in effect (OMB Memo M-26-11).

Key Scaffolding Requirements 29 CFR 1926.451

  • Each scaffold and scaffold component supports, without failure, its own weight and at least 4 times the maximum intended load, except as provided in (a)(2)-(a)(5) and (g) (1926.451(a)(1))
  • Provide fall protection for each employee on a scaffold more than 10 feet above a lower level, with the system (g)(1)(i)-(vii) sets for the scaffold type: personal fall arrest, guardrails, or both
  • A competent person inspects scaffolds and scaffold components for visible defects before each work shift and after any occurrence which could affect structural integrity (1926.451(f)(3))
  • Train each employee who performs work on a scaffold (1926.454)
  • Provide access by ladder, stair tower, ramp, walkway, integral prefabricated scaffold access or similar means when platforms are more than 2 feet above or below a point of access; crossbraces are not used as a means of access (1926.451(e)(1))
  • Follow the requirements specific to the scaffold type (1926.452)

Who enforces it in Florida: Federal OSHA inspects private construction employers; Florida has no State Plan.

The compliance checklist, the paragraphs OSHA cites nationally and what an inspector checks under 29 CFR 1926.451 are on the 29 CFR 1926.451 page.

Most-Cited Scaffolding Paragraphs in Florida, FY2025

Federal OSHA issued 232 citations under 29 CFR 1926.451 to Florida construction employers in FY2025. The paragraphs cited most, with the official text. A serious violation carries up to $16,550.

  • 1

    1926.451(g)(1) 39 citations

    “Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through …”

  • 2

    1926.451(b)(1) 37 citations

    “Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:”

  • 3

    1926.451(e)(1) 30 citations

    “When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type …”

  • 4

    1926.451(c)(2) 20 citations

    “Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.”

  • 5

    1926.451(f)(3) 14 citations

    “Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural …”

  • 6

    1926.451(g)(1)(vii) 9 citations

    “For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or …”

HazComFast count from the Labor Department's OSHA enforcement data: citations issued in FY2025 to construction employers (NAICS 23), by the paragraph cited. Paragraph text: eCFR, current as of September 24, 2026. data.dol.gov

Florida Safety & Enforcement Profile

26,559

Federal construction citations (national, FY2025)
2,403 of them in Florida (HazComFast count)

Federal OSHA

Enforces private construction

  • Construction trades inspected most in Florida, FY2025: Roofing Contractors (596), Framing Contractors (275) and Commercial and Institutional Building Construction (117), out of 1,662 inspections opened (federal OSHA and State Plan combined).
  • Cited most under 29 CFR 1926.451 in Florida, FY2025: Masonry Contractors (50), Siding Contractors (38) and Residential Remodelers (21), of 232 citations.
  • Construction fatality rate in Florida, 2024: 9.4 per 100,000 full-time workers, 20th highest of the 40 states BLS published (all industries: 2.9).

HazComFast count from the Labor Department's OSHA enforcement data: inspections of construction employers (NAICS 23) opened from October 1, 2024 to September 30, 2025, federal OSHA and State Plan combined, grouped by the inspected employer's 2022 NAICS industry. HazComFast count from the Labor Department's OSHA enforcement data: citations issued in FY2025 to construction employers (NAICS 23), grouped by the cited employer's 2022 NAICS industry. Industry names are the Census Bureau's 2022 NAICS titles. data.dol.gov · BLS fatality rates by state, 2024

Scaffolding FAQ for Florida

Which Florida construction trades are cited most under Scaffolding?

In FY2025, federal OSHA issued 232 citations under 29 CFR 1926.451 to Florida construction employers, most often to Masonry Contractors (50), Siding Contractors (38) and Residential Remodelers (21) (HazComFast count from Labor Department enforcement data, by the cited employer's NAICS industry). Federal OSHA inspects these employers directly, since Florida has no state plan covering the private sector. For context, federal OSHA issued 2,403 citations across 1,090 inspections of Florida construction employers in FY2025 (HazComFast count from Labor Department enforcement data). On a jobsite, the standard on this subject is 29 CFR 1926.451.

How often is Scaffolding cited on Florida jobsites?

OSHA's cited-standards tool does not break Florida out, but the Labor Department's enforcement data do: in FY2025, federal OSHA issued 2,403 citations across 1,090 inspections of Florida construction employers, 232 of them under 29 CFR 1926.451 (HazComFast count). Florida's fatality figures are shown above.

Who enforces scaffold safety in Florida?

Federal OSHA. Florida has no State Plan, so federal OSHA inspects and cites 29 CFR 1926.451 directly, using the federal maximums ($16,550 serious / $165,514 willful-repeat in 2026). Scaffolding (1926.451) was the 4th most-cited standard in federal construction inspections in FY2025, with 2,152 citations (OSHA Frequently Cited Standards).

What is a fatal Florida scaffold case?

In 2023, a 22-year-old worker was killed at a Miami Beach site when a scaffold hoist arm detached and struck him. OSHA cited the contractor (Stucco Works) for unsafe scaffolding, struck-by hazards and falls up to 27 feet, and proposed $74,555; after an administrative law judge's decision the case closed on May 12, 2025 at $40,000 (sources: US DOL / OSHA news release, January 2024; OSHA inspection record 1683379.015).

Can I get free OSHA help in Florida without an inspection?

Yes. OSHA's On-Site Consultation Program in Florida is USF SafetyFlorida Consultation Program (University of South Florida). OSHA describes it this way: "Primarily for smaller businesses, no-cost, confidential consultations help employers identify and address hazards and establish or improve safety and health programs." Consultations are separate from OSHA enforcement, and the employer commits to correcting serious hazards.

How often does federal OSHA cite 29 CFR 1926.451 in Florida construction?

In FY2025, federal OSHA cited 29 CFR 1926.451 (Scaffolding) 232 times in 92 inspections of Florida construction employers, with $761,344 in penalties at current amounts ($986,395 as first proposed), 9.7% of the 2,403 citations those inspections produced. It ranked fourth of the 86 standards cited. (HazComFast count from U.S. Department of Labor OSHA enforcement data, retrieved 2026-09-26.)

Scaffolding Guides & Resources

Want the complete federal guide for this standard?

Compare this combination against any other state and standard with the enforcement risk lookup.

Sources & verification

Penalty amounts and plan-type data were checked on 2026-10-19 against eCFR, OSHA.gov, and the Federal Register. This page is informational and not legal advice; consult the enforcing agency or counsel for your specific situation.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers

New sign-ups are paused. The free tools below need no account, and customers can log in as usual.

Your account keeps working as usual. Cancel anytime.