Petroleum · CAS Database
Mineral Spirits
Mineral Spirits (CAS 8052-41-3): Paint thinner and degreaser. What OSHA's HazCom rules ask of it on a job site, and where its Safety Data Sheet comes from: your supplier.
CAS Registry Number CAS 8052-41-3 · also known as White spirit, Stoddard solvent, Varsol
Overview
Paint thinner and degreaser
Get the SDS for your product
Mineral Spirits is a substance. What you hold is a product: a drum, jug or cylinder from a supplier, with its own formula and its own sheet. These are official sheets for mineral spirits products from US suppliers, opened on Oct 21, 2026.
Klean Strip Paint Thinner
W. M. Barr
Number CKPT94402, EKPT94401, GKPT94002 and 5 more · Date on the sheet Aug 9, 2023
Klean Strip Odorless Mineral Spirits
W. M. Barr
Number GKSP94006P, QKSP94005, QKSP945 and 2 more · Date on the sheet Nov 5, 2021
Low odor mineral spirits
Sunnyside Corporation
Number Product 80332 · Revision date Nov 8, 2013
Paint thinner
Sunnyside Corporation
Number Product 70132 · Revision date May 29, 2015
Each link opens the maker's or supplier's own copy. Match the product name, the number and the revision date with your container, and keep the current sheet for the exact product you hold. Other products: SDS Lookup.
What the sheet of a mineral spirits product sets off
Each line is a condition on the sheet you hold, and it names the paragraph it rests on. The paragraphs were verified against the eCFR on Oct 19, 2026. General industry follows 29 CFR part 1910 and construction follows part 1926.
If Section 2 lists a classification or a hazard not otherwise classified
Written program with its chemical list, training, sheet access each shift and workplace labels. (29 CFR 1910.1200(c), (e)(1), (f)(6), (g)(8), (h)(1); 1926.59)
If Section 2 lists a flammable liquid
Electrical connection of nozzle and container at dispensing, for Category 1 or 2 or Category 3 below 100 °F, in the industrial plants that paragraph (e)(1) describes (general industry). Construction names Category 1, 2 and 3 in its own paragraph. (29 CFR 1910.106(e)(1), (e)(6)(ii); 1926.152(e)(2))
If Section 8 calls for a respirator
The employer provides one when necessary to protect health and keeps a respiratory protection program. (29 CFR 1910.134(a)(2); 1926.103)
If Section 8 lists an OSHA exposure limit
The tables are in 1910.1000 and, in construction, Table 1 of 1926.55. (29 CFR 1910.1000; 1926.55)
If the product is a consumer product
Outside the standard when the employer shows use as its maker intended at no more than consumer exposure. Hours of use every shift can fall outside that. (29 CFR 1910.1200(b)(6)(ix))
A container you fill from the sheet carries a label built from Section 2 of that sheet. The secondary container label maker makes it from what you type in, in English and Spanish if you tick both, and fills in nothing from a list.
Mineral Spirits on the job site
Mineral spirits (Stoddard solvent) is the mild, slower-evaporating solvent for parts cleaning, degreasing, brush cleanup, and concrete form-release. Its PEL is comparatively high, 200 ppm on a construction site (Table 1 to 29 CFR 1926.55) and 500 ppm in general industry (Table Z-1), and its odor is mild, which is exactly why it's easy to overuse in a poorly ventilated space and why repeated bare-hand contact is common, which leads to defatting dermatitis (dry, cracked skin) more often than acute poisoning.
Here the glove lesson flips: mineral spirits is an aliphatic hydrocarbon, and nitrile is commonly listed as resisting it, often a reasonable choice (unlike acetone or toluene); mineral spirits products differ in composition, so confirm on the permeation data for the exact glove and product. It is still combustible, so keep it away from hot work and store rags in a covered metal can to prevent a soaked-rag fire. Good ventilation and gloves handle nearly all of the routine risk.
Key takeaways
- The common harm is defatting dermatitis from bare-hand contact: wear gloves for routine cleanup.
- Unlike ketones/aromatics, nitrile is commonly listed as resisting mineral spirits; confirm the glove's permeation data for your product and task.
- Still combustible: keep it from hot work and store soaked rags in a covered metal can.
Field guidance for planning and training, not a substitute for the manufacturer Safety Data Sheet, which gives the exposure limits, PPE, and handling for your specific product.
OSHA Exposure Limits
OSHA permissible exposure limit (PEL) and secondary limit for Mineral Spirits on a US construction site. Where a substance-specific 1926 standard applies, its codified limit is shown; otherwise the figure comes from Table 1 to 29 CFR 1926.55, the construction air-contaminants table. Where Table 1 gives no figure, either the substance has its own standard (the row says "see 1926.xxxx" and this page names that standard) or Table 1 sets no limit for it. In both cases Section 8 of the Safety Data Sheet lists the limits other bodies recommend and the supplier's controls.
| Limit | Value | Basis / citation |
|---|---|---|
| OSHA PEL (8-hr TWA) | 200 ppm | 29 CFR 1926.55 Table 1 |
| Action level | See SDS / standard | Not all substances define an action level |
| Averaging period | 8-hour TWA | The ACGIH TLV and NIOSH REL are recommendations; some are lower than the PEL |
Many OSHA PELs date to 1971 and may be less protective than current ACGIH/NIOSH values; always check Section 8 of the manufacturer SDS for the limits it lists, which can be lower than the PEL, and for its control guidance. Not legal advice.
Where Mineral Spirits shows up on the job
Trades that commonly handle Mineral Spirits, each with an OSHA HazCom guide built for the chemicals and tasks on that kind of site:
OSHA & HazCom Compliance Requirements
For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Where a product your crews use contains Mineral Spirits and is a hazardous chemical under the standard (its supplier's label and SDS say so), the employer must:
- •Maintain an accessible SDS for Mineral Spirits (readily accessible during each work shift, 29 CFR 1910.1200(g)(8))
- •Keep the supplier's label on shipped containers (29 CFR 1910.1200(f)(1)) and mark workplace containers with the shipped-label elements or the product identifier and hazard information (29 CFR 1910.1200(f)(6)); a portable container for immediate use by the person who filled it needs none (1910.1200(f)(8))
- •Include it in the workplace chemical inventory
- •Train employees on hazards before initial assignment
- •Retain employee exposure and medical records per 29 CFR 1910.1020: exposure records for at least 30 years, medical records for the duration of employment plus 30 years. An SDS itself may be discarded if a record of the chemical's identity, where it was used and when is kept for 30 years
HazCom (1910.1200 / construction 1926.59) covers hazard classification, labels, SDSs, the written program (with its chemical list and the rules for non-routine tasks and multi-employer sites) and training. It does not impose chemical storage segregation. Flammable & combustible liquid storage for construction is 29 CFR 1926.152; segregation of incompatibles is planned from SDS Sections 7 and 10. Exemptions apply, such as a consumer product used the way a consumer would use it (1910.1200(b)(6)(ix)). Not legal advice; state-plan states may have stricter rules.
Handling & Secondary-Container Labeling
When you transfer Mineral Spirits into a workplace (secondary) container, OSHA gives two compliant options under 29 CFR 1910.1200(f)(6):
- •(f)(6)(i): full GHS label elements (as on the shipped container)
- •(f)(6)(ii): product identifier + words/pictures/symbols (or combination) that provide AT LEAST general information on the hazards and, with the other information immediately available under the HazCom program, the specific hazards
There is no volume/size cutoff for secondary containers: the ≤100 ml / ≤3 ml accommodations (29 CFR 1910.1200(f)(12) (added by the HCS 2024 final rule)) apply only to the manufacturer's shipped container. A portable container filled for the immediate use of the worker who fills it needs no label (29 CFR 1910.1200(f)(8)).
GHS Hazard Classification under OSHA HCS
OSHA's Hazard Communication Standard adopts the GHS (primarily GHS Revision 7 (HCS 2024)). It uses 8 hazard pictograms (Appendix C, Figure C.1); a label carries only the ones its classification calls for. The Environment pictogram (GHS09) is not required by OSHA. Not in App C; outside OSHA jurisdiction; voluntary.
The eight HCS pictograms:
For flammable liquids, OSHA classifies by flash point and boiling point (App B.6.1 / 1910.106(a)):
- •Category 1: FP < 73.4°F AND BP <= 95°F
- •Category 2: FP < 73.4°F AND BP > 95°F
- •Category 3: FP >= 73.4°F AND <= 140°F
- •Category 4: FP > 140°F AND <= 199.4°F
The GHS classification of a product that contains Mineral Spirits comes from Section 2 of that product's Safety Data Sheet: the pictograms and categories on your labels follow that section.
HCS 2024 Update Deadlines
Under the federal Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7):
- •May 19, 2026: manufacturers, importers, and distributors of Mineral Spirits sold as a substance update its labels & SDSs (1910.1200(j)(2)(i))
- •November 20, 2026: for the substance, employers, as necessary, update alternative workplace labels, the written program & training for newly identified hazards (1910.1200(j)(2)(ii))
- •For a mixture that contains Mineral Spirits: November 19, 2027 for manufacturers, importers and distributors, and May 19, 2028 for employers, as necessary (1910.1200(j)(3))
During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both. These are the federal OSHA dates; State Plans adopt the update on their own schedules, so check your state.
Quick Actions
Put Mineral Spirits on your written inventory, print the workplace label your containers need, and keep your supplier’s sheet reachable on the jobsite.
The safety data sheet for your product comes from the supplier who sold it to you. No public registry can provide it. For the underlying chemistry, the public record is on PubChem.
Where this fits in your HazCom program
- SDS management: collecting the sheet, keeping it current, and making it readable during each work shift.
- GHS labels & workplace labeling: what has to appear on the shipped container, and what a secondary container needs instead.
Free Compliance Tools for Mineral Spirits
Also on a concrete & masonry job
Frequently Asked Questions
What is Mineral Spirits (CAS 8052-41-3)?
Paint thinner and degreaser
What are the OSHA HazCom requirements for Mineral Spirits on a construction site?
For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Where a product you use containing Mineral Spirits is a hazardous chemical under the standard (its supplier's label and SDS say so), you must keep its Safety Data Sheet accessible, keep the supplier's label on shipped containers and label workplace containers under (f)(6), list it in the written program's chemical inventory, and train workers on its hazards at initial assignment. Exemptions apply, such as a consumer product used the way a consumer would use it (1910.1200(b)(6)(ix)).
What is the OSHA permissible exposure limit (PEL) for Mineral Spirits?
OSHA's permissible exposure limit for Mineral Spirits is 200 ppm (8-hour TWA), per 29 CFR 1926.55 Table 1. 1,150 mg/m³. The ACGIH TLV and the NIOSH REL are recommendations, not limits OSHA enforces on their own. Where one is lower than the PEL, many employers adopt it as their working limit. Section 8 of the manufacturer Safety Data Sheet lists the exposure limits the supplier reports and its control advice; the limit OSHA enforces is the one in its standard, and a State Plan may set its own.
When does the updated HCS 2024 labeling apply to Mineral Spirits?
Under the federal Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7), manufacturers, importers and distributors must comply by May 19, 2026 when Mineral Spirits is sold as a substance, and by November 19, 2027 for mixtures that contain it. Employers must, as necessary, update alternative workplace labels, the written program and training for newly identified hazards by November 20, 2026 for substances and May 19, 2028 for mixtures (29 CFR 1910.1200(j)). During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both. State Plans adopt the update on their own schedules, so check your state's dates.
How do I label a secondary (workplace) container of Mineral Spirits?
Under 29 CFR 1910.1200(f)(6) you have two options: (i) the label elements of (f)(1)(i) through (v): product identifier, signal word, hazard statements, pictograms and precautionary statements, with no supplier name or address needed, or (ii) the product identifier plus words, pictures, symbols, or a combination that provide at least general hazard information and that, with the other information immediately available to workers under the HazCom program, give the specific hazards. There is no volume/size cutoff for secondary containers. A portable container filled from a labeled container, kept under the control of the worker who fills it and used only by that worker within the same shift, does not require a label (29 CFR 1910.1200(f)(8)).
How long must SDS and exposure records for Mineral Spirits be kept?
Under 29 CFR 1910.1020, 30-year retention applies to employee exposure and medical records (medical records: duration of employment plus 30 years), not to SDSs generically. Where an SDS is not retained, a record of the chemical's identity, where it was used, and when must be kept for at least 30 years.
Where can I find the SDS for Mineral Spirits?
Under 29 CFR 1910.1200(g)(6) and (g)(7), the manufacturer or importer of Mineral Spirits must ensure that distributors and employers receive its Safety Data Sheet with the initial shipment and with the first shipment after the sheet is updated, and a distributor passes it on in its commercial shipments the same way. Retail and wholesale distributors that sell to employers over the counter or to commercial accounts have their own duties in (g)(7)(iii) to (vii), such as providing the sheet on request. HazComFast keeps the sheets you collect in one inventory per jobsite, searchable by product, manufacturer or CAS number, and your jobsite's SDS load onto the phone on their own.
Sources & Primary References
Regulatory data on this page comes from 29 CFR 1926.59 / 1910.1200 and substance-specific 1926 standards, last verified October 19, 2026 against eCFR, OSHA.gov, and the Federal Register. Physical-property data comes from PubChem; the source of a figure is in parentheses after it where one is given (NIOSH Pocket Guide, ICSC, or the dataset PubChem cites). Confirm it against the manufacturer Safety Data Sheet. This page is informational and is not legal advice.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.
Your account keeps working as usual. Cancel anytime.