What 29 CFR 1926.452 requires (plain English)
29 CFR 1926.452 provides the additional requirements applicable to specific types of scaffolds, within Subpart L (Scaffolds). Where 1926.451 sets the general requirements that apply to all scaffolds (capacity, platform construction, fall protection, access, and use) 1926.452 adds the requirements unique to each scaffold design.
The section is organized by scaffold type, with a paragraph for each: pole scaffolds, tube and coupler scaffolds, fabricated frame (tubular welded frame) scaffolds, plasterers' and decorators' scaffolds, bricklayers' square scaffolds, horse scaffolds, form and carpenters' bracket scaffolds, roof bracket scaffolds, outrigger scaffolds, pump jack scaffolds, ladder jack scaffolds (with their own limits), window jack scaffolds, repair bracket scaffolds, crawling boards, step/platform/trestle ladder scaffolds, single-point and two-point adjustable suspension scaffolds, multi-point and multi-level suspension scaffolds, catenary scaffolds, float (ship) scaffolds, interior hung scaffolds, needle beam scaffolds, mobile scaffolds and stilts; the section continues to paragraph (y). Each paragraph gives the requirements specific to that type. The foundations and the design factor of suspension ropes are in 1926.451, not here; the modifications of aerial lifts are in 1926.453. Inspection and erection requirements are in 1926.451 and training in 1926.454. Tiebacks are in 1926.451(d), not in paragraph (p).
For mobile scaffolds, casters and wheels are locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement while the scaffold is used in a stationary manner ((w)(2)); manual force to move the scaffold is applied as close to the base as practicable, but not more than 5 feet above the supporting surface ((w)(3)); the scaffold is stabilized to prevent tipping during movement ((w)(5)); employees ride only when the surface is within 3 degrees of level and free of pits, holes and obstructions, the height to base width ratio during movement is two to one or less unless the scaffold is designed to meet recognized stability tests, outrigger frames when used are on both sides, the propelling force of a power system is applied directly to the wheels at no more than 1 foot per second, and no employee is on a part extending beyond the wheels, casters or other supports ((w)(6)); before a scaffold is moved, each employee on it is made aware of the move ((w)(10)). The 2:1 ratio of (w)(6) is a condition of occupied movement, distinct from the general anti-overturning provisions of 1926.451(c).
In addition to the applicable requirements of 1926.451, the requirements in 1926.452 apply to the specific types of scaffolds indicated, and scaffolds not specifically addressed here, such as systems scaffolds, must meet the requirements of 1926.451. A scaffold therefore meets both the general rules and the rules for its type.