Hydrogen Sulfide (CAS 7783-06-4): Toxic gas in oil/gas and sewer industries. What OSHA's HazCom rules ask of it on a job site, and where its Safety Data Sheet comes from: your supplier.

CAS Registry Number CAS 7783-06-4 · also known as H2S, Sewer gas, Rotten egg gas

Overview

Toxic gas in oil/gas and sewer industries

Synonyms:H2SSewer gasRotten egg gas

Where workers encounter H2S gas

Hydrogen sulfide forms as organic matter decays. OSHA names sewage sludge, liquid manure, sulfur hot springs and natural gas as sources, and lists industrial processes that use or produce it: petroleum production and refining, sewer and wastewater treatment, agricultural silos and pits, textile manufacturing, pulp and paper processing, food processing, hot asphalt paving and mining.

The exposures OSHA describes are mostly work in or near places where the gas collects. Sanitation workers meet it cleaning or maintaining sewers and septic tanks, farm workers in manure storage tanks and pits, and oil and gas workers where it is present in deposits or produced when fuels are desulfurized. Confined spaces such as pits, manholes, tunnels and wells, windless or low-lying areas, marshy ground and hot weather all raise the risk of overexposure.

OSHA's own case list includes a sanitation worker who died rescuing a co-worker from an underground sewer vault, and four workers who died one after another in a landfill lift station, each entering to help the one before. No permit entry system had been established for that space.

Smell is not a reliable warning

The rotten-egg odor is noticeable at very low levels: OSHA's table puts the odor threshold between 0.01 and 1.5 ppm. At 100 ppm the same table lists loss of smell after 2 to 15 minutes, and OSHA warns that at high concentrations the ability to smell the gas can be lost instantly. A smell that fades is not a sign that the gas is gone.

Detection rests on instruments suited to the task. OSHA lists electronic meters, detector tubes, direct-reading gas monitors and alarm-only monitors among the equipment used to test atmospheres, and NIOSH Method 6013 for air samples analyzed in a laboratory.

OSHA Exposure Limits

OSHA sets one limit for construction and different ones for general industry, and NIOSH publishes a recommended limit and an IDLH value. A ceiling is not exceeded at any time; a peak is a short excursion above the ceiling that the general industry table allows only under its stated conditions; IDLH is the value NIOSH uses for respirator selection and escape.

Hydrogen sulfide exposure limits by sector and organization
SectorOrganizationType of limitDurationValueSource
ConstructionOSHA (enforceable)Permissible exposure limit8-hour time-weighted average10 ppm (15 mg/m³)29 CFR 1926.55, Table 1
General industryOSHA (enforceable)Acceptable ceiling concentrationAt any time20 ppm29 CFR 1910.1000, Table Z-2
General industryOSHA (enforceable)Acceptable maximum peak above the ceiling10 minutes, once per 8-hour shift, only if no other measurable exposure occurs50 ppm29 CFR 1910.1000, Table Z-2
ShipyardsOSHA (enforceable)Permissible exposure limit8 hours10 ppmOSHA hydrogen sulfide hazards page
All workNIOSH (recommended)Recommended exposure limit, ceiling10 minutes10 ppmNIOSH, as listed by OSHA
All workNIOSHImmediately dangerous to life or health (IDLH)Not a working limit100 ppmNIOSH, as listed by OSHA

Section 8 of the supplier's SDS lists the limits it applies to its product. State Plans can set their own limits.

GHS Classification

The manufacturer or importer of Hydrogen Sulfide (CAS 7783-06-4) classifies its hazards (29 CFR 1910.1200(d)(1)). You'll find them in Section 2, Hazard(s) identification, of the manufacturer's Safety Data Sheet (29 CFR 1910.1200(g)(2)(ii)).

Physical Properties

IUPAC Namesulfane
Molecular FormulaH2S
Molecular Weight34.08 g/mol
Boiling Point-76.59 °F at 760 mmHg (EPA, 1998)
Melting Point-121.9 °F (EPA, 1998)
Flash PointNot applicable: gas (NIOSH Pocket Guide)
Specific gravity of the liquid at the temperature shown0.916 at -76 °F (EPA, 1998)
Vapor Density (air = 1)1.19, heavier than air (NIOSH Pocket Guide)
Vapor Pressure15200 mmHg at 77.9 °F (EPA, 1998)
Solubility0.4 % (NIOSH, 2024)

A product sold under this name can differ in concentration or form; its own SDS gives its values.

OSHA & HazCom Compliance Requirements

For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Where a product your crews use contains Hydrogen Sulfide and is a hazardous chemical under the standard (its supplier's label and SDS say so), the employer must:

  • •Maintain an accessible SDS for Hydrogen Sulfide (readily accessible during each work shift, 29 CFR 1910.1200(g)(8))
  • •Keep the supplier's label on shipped containers (29 CFR 1910.1200(f)(1)) and mark workplace containers with the shipped-label elements or the product identifier and hazard information (29 CFR 1910.1200(f)(6)); a portable container for immediate use by the person who filled it needs none (1910.1200(f)(8))
  • •Include it in the workplace chemical inventory
  • •Train employees on hazards before initial assignment
  • •Retain employee exposure and medical records per 29 CFR 1910.1020: exposure records for at least 30 years, medical records for the duration of employment plus 30 years. An SDS itself may be discarded if a record of the chemical's identity, where it was used and when is kept for 30 years

HazCom (1910.1200 / construction 1926.59) covers hazard classification, labels, SDSs, the written program (with its chemical list and the rules for non-routine tasks and multi-employer sites) and training. It does not impose chemical storage segregation. Flammable & combustible liquid storage for construction is 29 CFR 1926.152; segregation of incompatibles is planned from SDS Sections 7 and 10. Exemptions apply, such as a consumer product used the way a consumer would use it (1910.1200(b)(6)(ix)). Not legal advice; state-plan states may have stricter rules.

Handling & Secondary-Container Labeling

When you transfer Hydrogen Sulfide into a workplace (secondary) container, OSHA gives two compliant options under 29 CFR 1910.1200(f)(6):

  • •(f)(6)(i): full GHS label elements (as on the shipped container)
  • •(f)(6)(ii): product identifier + words/pictures/symbols (or combination) that provide AT LEAST general information on the hazards and, with the other information immediately available under the HazCom program, the specific hazards

There is no volume/size cutoff for secondary containers: the ≤100 ml / ≤3 ml accommodations (29 CFR 1910.1200(f)(12) (added by the HCS 2024 final rule)) apply only to the manufacturer's shipped container. A portable container filled for the immediate use of the worker who fills it needs no label (29 CFR 1910.1200(f)(8)).

GHS Hazard Classification under OSHA HCS

OSHA's Hazard Communication Standard adopts the GHS (primarily GHS Revision 7 (HCS 2024)). It uses 8 hazard pictograms (Appendix C, Figure C.1); a label carries only the ones its classification calls for. The Environment pictogram (GHS09) is not required by OSHA. Not in App C; outside OSHA jurisdiction; voluntary.

The eight HCS pictograms:

FlameFlame Over CircleExclamation MarkExploding BombCorrosionGas CylinderHealth HazardSkull and Crossbones

The GHS classification of a product that contains Hydrogen Sulfide comes from Section 2 of that product's Safety Data Sheet: the pictograms and categories on your labels follow that section.

HCS 2024 Update Deadlines

Under the federal Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7):

  • •May 19, 2026: manufacturers, importers, and distributors of Hydrogen Sulfide sold as a substance update its labels & SDSs (1910.1200(j)(2)(i))
  • •November 20, 2026: for the substance, employers, as necessary, update alternative workplace labels, the written program & training for newly identified hazards (1910.1200(j)(2)(ii))
  • •For a mixture that contains Hydrogen Sulfide: November 19, 2027 for manufacturers, importers and distributors, and May 19, 2028 for employers, as necessary (1910.1200(j)(3))

During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both. These are the federal OSHA dates; State Plans adopt the update on their own schedules, so check your state.

Monitoring, alarms and rescue planning

OSHA's sequence starts with the task: identify the processes that could release or produce hydrogen sulfide, eliminate the source where possible, then control exposure with ventilation and work practices, and with respirators where those are not enough.

A qualified person tests the air with the right equipment, before and at regular times during work where exposure is possible. In a confined space the atmosphere is tested from outside before entry and monitored during the work under the permit-space rules that apply. The detector's own checks, bump tests and calibration, are part of the plan.

Before the work starts, the crew agrees on what an alarm means on this job: who leaves, by which route, and who calls for help. Rescue is organized before entry. OSHA warns that first responders entering areas with high hydrogen sulfide levels need training and protection, including positive-pressure self-contained breathing apparatus and a safety line for rapid exit.

Where respirators are used, OSHA points to an air-purifying respirator with hydrogen sulfide canisters or cartridges below 100 ppm, and to a full-facepiece pressure-demand SCBA, or a supplied-air respirator with an auxiliary self-contained supply, at or above 100 ppm, inside a respiratory protection program under 29 CFR 1910.134.

Quick Actions

Put Hydrogen Sulfide on your written inventory, print the workplace label your containers need, and keep your supplier’s sheet reachable on the jobsite.

The safety data sheet for your product comes from the supplier who sold it to you. No public registry can provide it. For the underlying chemistry, the public record is on PubChem.

Where this fits in your HazCom program

  • SDS management: collecting the sheet, keeping it current, and making it readable during each work shift.
  • GHS labels & workplace labeling: what has to appear on the shipped container, and what a secondary container needs instead.

Frequently Asked Questions

What is Hydrogen Sulfide (CAS 7783-06-4)?

Toxic gas in oil/gas and sewer industries

What are the OSHA HazCom requirements for Hydrogen Sulfide on a construction site?

For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Where a product you use containing Hydrogen Sulfide is a hazardous chemical under the standard (its supplier's label and SDS say so), you must keep its Safety Data Sheet accessible, keep the supplier's label on shipped containers and label workplace containers under (f)(6), list it in the written program's chemical inventory, and train workers on its hazards at initial assignment. Exemptions apply, such as a consumer product used the way a consumer would use it (1910.1200(b)(6)(ix)).

What is the OSHA permissible exposure limit (PEL) for Hydrogen Sulfide?

OSHA lists Hydrogen Sulfide in 29 CFR 1926.55 Table 1 under the entry "Hydrogen sulfide", at 10 ppm (15 mg/m³) as an 8-hour time-weighted average. Section 8 of the manufacturer Safety Data Sheet lists the exposure limits the supplier reports and its control advice; the limit OSHA enforces is the one in its standard, and a State Plan may set its own.

When does the updated HCS 2024 labeling apply to Hydrogen Sulfide?

Under the federal Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7), manufacturers, importers and distributors must comply by May 19, 2026 when Hydrogen Sulfide is sold as a substance, and by November 19, 2027 for mixtures that contain it. Employers must, as necessary, update alternative workplace labels, the written program and training for newly identified hazards by November 20, 2026 for substances and May 19, 2028 for mixtures (29 CFR 1910.1200(j)). During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both. State Plans adopt the update on their own schedules, so check your state's dates.

How do I label a secondary (workplace) container of Hydrogen Sulfide?

Under 29 CFR 1910.1200(f)(6) you have two options: (i) the label elements of (f)(1)(i) through (v): product identifier, signal word, hazard statements, pictograms and precautionary statements, with no supplier name or address needed, or (ii) the product identifier plus words, pictures, symbols, or a combination that provide at least general hazard information and that, with the other information immediately available to workers under the HazCom program, give the specific hazards. There is no volume/size cutoff for secondary containers. A portable container filled from a labeled container, kept under the control of the worker who fills it and used only by that worker within the same shift, does not require a label (29 CFR 1910.1200(f)(8)).

How long must SDS and exposure records for Hydrogen Sulfide be kept?

Under 29 CFR 1910.1020, 30-year retention applies to employee exposure and medical records (medical records: duration of employment plus 30 years), not to SDSs generically. Where an SDS is not retained, a record of the chemical's identity, where it was used, and when must be kept for at least 30 years.

Where can I find the SDS for Hydrogen Sulfide?

Under 29 CFR 1910.1200(g)(6) and (g)(7), the manufacturer or importer of Hydrogen Sulfide must ensure that distributors and employers receive its Safety Data Sheet with the initial shipment and with the first shipment after the sheet is updated, and a distributor passes it on in its commercial shipments the same way. Retail and wholesale distributors that sell to employers over the counter or to commercial accounts have their own duties in (g)(7)(iii) to (vii), such as providing the sheet on request. HazComFast keeps the sheets you collect in one inventory per jobsite, searchable by product, manufacturer or CAS number, and your jobsite's SDS load onto the phone on their own.

Regulatory data on this page comes from 29 CFR 1926.59 / 1910.1200 and substance-specific 1926 standards, last verified October 19, 2026 against eCFR, OSHA.gov, and the Federal Register. Physical-property data comes from PubChem; the source of a figure is in parentheses after it where one is given (NIOSH Pocket Guide, ICSC, or the dataset PubChem cites). Confirm it against the manufacturer Safety Data Sheet. This page is informational and is not legal advice.

Looking for more chemicals?

Browse our database of industrial chemicals with GHS data, safety information, and compliance tools.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.