Skip to content

Approaching: Feb 1, 2027 — 300A Posting Begins. Get ready →

Metals · CAS Database

Zinc Oxide

Zinc Oxide (CAS 1314-13-2): Sunscreen and rubber additive. What OSHA's HazCom rules ask of it on a job site, and where its Safety Data Sheet comes from: your supplier.

CAS Registry Number CAS 1314-13-2 · also known as ZnO, Zinc white

Overview

Sunscreen and rubber additive

Synonyms:ZnOZinc white

Zinc Oxide on the job site

Zinc oxide fume is the classic galvanized-steel hazard: welding, cutting, or brazing galvanized (zinc-coated) steel vaporizes the coating and releases a fine white fume. Breathe enough of it in a day and you get metal fume fever — chills, fever, muscle aches, and a metallic taste that come on hours later, often that evening (the “Monday-morning” or “zinc chills” pattern), and clear in a day or two. It's self-limiting, but it's miserable, recurrent, and a clear sign the exposure was uncontrolled.

The fix is to grind the galvanizing back a couple of inches from the weld zone, run local exhaust or an on-gun extractor, and never weld galvanized in a still, enclosed space. The 5 mg/m³ fume PEL can be exceeded when a bead is laid straight through the coating with no ventilation; air sampling shows whether it is. If a crew reports “welder's flu,” treat it as an exposure event, not a coincidence.

Key takeaways

  • Welding galvanized steel causes metal fume fever — flu-like symptoms that hit hours later and recur.
  • Grind the zinc coating back from the weld zone and run local exhaust; never weld galvanized in still air.
  • “Welder's flu” is an uncontrolled-exposure signal, not a bug going around.

Field guidance for planning and training, not a substitute for the manufacturer Safety Data Sheet, which gives the exposure limits, PPE, and handling for your specific product.

OSHA Exposure Limits

OSHA permissible exposure limit (PEL) and secondary limit for Zinc Oxide on a US construction site. Where a substance-specific 1926 standard applies, its codified limit is shown; otherwise the figure comes from Table 1 to 29 CFR 1926.55, the construction air-contaminants table. Where Table 1 gives no figure, either the substance has its own standard (the row says "see 1926.xxxx" and this page names that standard) or Table 1 sets no limit for it. In both cases Section 8 of the Safety Data Sheet lists the limits other bodies recommend and the supplier's controls.

LimitValueBasis / citation
OSHA PEL (8-hr TWA)5 mg/m³29 CFR 1926.55 Table 1OSHA entry: Zinc oxide fume
Action levelSee SDS / standardNot all substances define an action level
Averaging period8-hour TWAThe ACGIH TLV and NIOSH REL are recommendations; some are lower than the PEL

Many OSHA PELs date to 1971 and may be less protective than current ACGIH/NIOSH values; always check Section 8 of the manufacturer SDS for the limits it lists, which can be lower than the PEL, and for its control guidance. Not legal advice.

GHS Classification

The manufacturer or importer of Zinc Oxide (CAS 1314-13-2) classifies its hazards (29 CFR 1910.1200(d)(1)). You'll find them in Section 2, Hazard(s) identification, of the manufacturer's Safety Data Sheet (29 CFR 1910.1200(g)(2)(ii)).

Physical Properties

IUPAC Namezinc oxygen(2-)
Molecular FormulaOZn
Molecular Weight81.4 g/mol
Melting Point3587 °F (NIOSH, 2024)
Specific gravity (water = 1)5.61 (NIOSH, 2024) - Denser than water; will sink
Vapor Pressure0 mmHg (approx) (NIOSH, 2024)
Solubility0.0004 % at 64 °F (NIOSH, 2024)

A product sold under this name can differ in concentration or form; its own SDS gives its values.

Where Zinc Oxide shows up on the job

Trades that commonly handle Zinc Oxide, each with an OSHA HazCom guide built for the chemicals and tasks on that kind of site:

OSHA & HazCom Compliance Requirements

For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Where a product your crews use contains Zinc Oxide and is a hazardous chemical under the standard (its supplier's label and SDS say so), the employer must:

  • •Maintain an accessible SDS for Zinc Oxide (readily accessible during each work shift, 29 CFR 1910.1200(g)(8))
  • •Keep the supplier's label on shipped containers (29 CFR 1910.1200(f)(1)) and mark workplace containers with the shipped-label elements or the product identifier and hazard information (29 CFR 1910.1200(f)(6)); a portable container for immediate use by the person who filled it needs none (1910.1200(f)(8))
  • •Include it in the workplace chemical inventory
  • •Train employees on hazards before initial assignment
  • •Retain employee exposure and medical records per 29 CFR 1910.1020: exposure records for at least 30 years, medical records for the duration of employment plus 30 years. An SDS itself may be discarded if a record of the chemical's identity, where it was used and when is kept for 30 years

HazCom (1910.1200 / construction 1926.59) covers hazard classification, labels, SDSs, the written program (with its chemical list and the rules for non-routine tasks and multi-employer sites) and training. It does not impose chemical storage segregation. Flammable & combustible liquid storage for construction is 29 CFR 1926.152; segregation of incompatibles is planned from SDS Sections 7 and 10. Exemptions apply, such as a consumer product used the way a consumer would use it (1910.1200(b)(6)(ix)). Not legal advice; state-plan states may have stricter rules.

Handling & Secondary-Container Labeling

When you transfer Zinc Oxide into a workplace (secondary) container, OSHA gives two compliant options under 29 CFR 1910.1200(f)(6):

  • •(f)(6)(i): full GHS label elements (as on the shipped container)
  • •(f)(6)(ii): product identifier + words/pictures/symbols (or combination) that provide AT LEAST general information on the hazards and, with the other information immediately available under the HazCom program, the specific hazards

There is no volume/size cutoff for secondary containers: the ≤100 ml / ≤3 ml accommodations (29 CFR 1910.1200(f)(12) (added by the HCS 2024 final rule)) apply only to the manufacturer's shipped container. A portable container filled for the immediate use of the worker who fills it needs no label (29 CFR 1910.1200(f)(8)).

GHS Hazard Classification under OSHA HCS

OSHA's Hazard Communication Standard adopts the GHS (primarily GHS Revision 7 (HCS 2024)). It uses 8 hazard pictograms (Appendix C, Figure C.1); a label carries only the ones its classification calls for. The Environment pictogram (GHS09) is not required by OSHA. Not in App C; outside OSHA jurisdiction; voluntary.

The eight HCS pictograms:

FlameFlame Over CircleExclamation MarkExploding BombCorrosionGas CylinderHealth HazardSkull and Crossbones

For flammable liquids, OSHA classifies by flash point and boiling point (App B.6.1 / 1910.106(a)):

  • •Category 1: FP < 73.4°F AND BP <= 95°F
  • •Category 2: FP < 73.4°F AND BP > 95°F
  • •Category 3: FP >= 73.4°F AND <= 140°F
  • •Category 4: FP > 140°F AND <= 199.4°F

The GHS classification of a product that contains Zinc Oxide comes from Section 2 of that product's Safety Data Sheet: the pictograms and categories on your labels follow that section.

HCS 2024 Update Deadlines

Under the federal Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7):

  • •May 19, 2026: manufacturers, importers, and distributors of Zinc Oxide sold as a substance update its labels & SDSs (1910.1200(j)(2)(i))
  • •November 20, 2026: for the substance, employers, as necessary, update alternative workplace labels, the written program & training for newly identified hazards (1910.1200(j)(2)(ii))
  • •For a mixture that contains Zinc Oxide: November 19, 2027 for manufacturers, importers and distributors, and May 19, 2028 for employers, as necessary (1910.1200(j)(3))

During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both. These are the federal OSHA dates; State Plans adopt the update on their own schedules, so check your state.

Quick Actions

Put Zinc Oxide on your written inventory, print the workplace label your containers need, and keep your supplier’s sheet reachable on the jobsite.

The safety data sheet for your product comes from the supplier who sold it to you. No public registry can provide it. For the underlying chemistry, the public record is on PubChem.

Where this fits in your HazCom program

  • SDS management: collecting the sheet, keeping it current, and making it readable during each work shift.
  • GHS labels & workplace labeling: what has to appear on the shipped container, and what a secondary container needs instead.

Frequently Asked Questions

What is Zinc Oxide (CAS 1314-13-2)?

Sunscreen and rubber additive

What are the OSHA HazCom requirements for Zinc Oxide on a construction site?

For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Where a product you use containing Zinc Oxide is a hazardous chemical under the standard (its supplier's label and SDS say so), you must keep its Safety Data Sheet accessible, keep the supplier's label on shipped containers and label workplace containers under (f)(6), list it in the written program's chemical inventory, and train workers on its hazards at initial assignment. Exemptions apply, such as a consumer product used the way a consumer would use it (1910.1200(b)(6)(ix)).

What is the OSHA permissible exposure limit (PEL) for Zinc Oxide?

OSHA lists Zinc Oxide in 29 CFR 1926.55 Table 1 under the entry "Zinc oxide fume", at 5 mg/m³ as an 8-hour time-weighted average. Section 8 of the manufacturer Safety Data Sheet lists the exposure limits the supplier reports and its control advice; the limit OSHA enforces is the one in its standard, and a State Plan may set its own.

When does the updated HCS 2024 labeling apply to Zinc Oxide?

Under the federal Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7), manufacturers, importers and distributors must comply by May 19, 2026 when Zinc Oxide is sold as a substance, and by November 19, 2027 for mixtures that contain it. Employers must, as necessary, update alternative workplace labels, the written program and training for newly identified hazards by November 20, 2026 for substances and May 19, 2028 for mixtures (29 CFR 1910.1200(j)). During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both. State Plans adopt the update on their own schedules, so check your state's dates.

How do I label a secondary (workplace) container of Zinc Oxide?

Under 29 CFR 1910.1200(f)(6) you have two options: (i) the label elements of (f)(1)(i) through (v): product identifier, signal word, hazard statements, pictograms and precautionary statements, with no supplier name or address needed, or (ii) the product identifier plus words, pictures, symbols, or a combination that provide at least general hazard information and that, with the other information immediately available to workers under the HazCom program, give the specific hazards. There is no volume/size cutoff for secondary containers. A portable container filled from a labeled container, kept under the control of the worker who fills it and used only by that worker within the same shift, does not require a label (29 CFR 1910.1200(f)(8)).

How long must SDS and exposure records for Zinc Oxide be kept?

Under 29 CFR 1910.1020, 30-year retention applies to employee exposure and medical records (medical records: duration of employment plus 30 years), not to SDSs generically. Where an SDS is not retained, a record of the chemical's identity, where it was used, and when must be kept for at least 30 years.

Where can I find the SDS for Zinc Oxide?

Under 29 CFR 1910.1200(g)(6) and (g)(7), the manufacturer or importer of Zinc Oxide must ensure that distributors and employers receive its Safety Data Sheet with the initial shipment and with the first shipment after the sheet is updated, and a distributor passes it on in its commercial shipments the same way. Retail and wholesale distributors that sell to employers over the counter or to commercial accounts have their own duties in (g)(7)(iii) to (vii), such as providing the sheet on request. HazComFast keeps the sheets you collect in one inventory per jobsite, searchable by product, manufacturer or CAS number, and your jobsite's SDS load onto the phone on their own.

Regulatory data on this page comes from 29 CFR 1926.59 / 1910.1200 and substance-specific 1926 standards, last verified October 19, 2026 against eCFR, OSHA.gov, and the Federal Register. Physical-property data comes from PubChem; the source of a figure is in parentheses after it where one is given (NIOSH Pocket Guide, ICSC, or the dataset PubChem cites). Confirm it against the manufacturer Safety Data Sheet. This page is informational and is not legal advice.

Looking for more chemicals?

Browse our database of industrial chemicals with GHS data, safety information, and compliance tools.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)

HazComFast Pro

$199/mo

10 jobsites, unlimited chemicals, unlimited workers