Overview
Oxidizer and pollutant
Nitrogen Dioxide on the job site
Nitrogen dioxide is a byproduct gas, not a product: it comes off welding and combustion (engine exhaust, gas heaters), off nitric-acid reactions with metal, and after blasting. Its hazard is the same delayed one that makes nitric-acid fume dangerous — NO₂ is only a mild irritant at first, so a worker can breathe a harmful dose without much immediate distress, then develop pulmonary edema hours later. That delay is exactly why it causes serious injury: the exposure feels survivable at the time.
The (C) 5 ppm ceiling is easy to exceed doing combustion or welding work in an enclosed, poorly ventilated space, or entering an area soon after blasting. Controls are ventilation, keeping engines and gas heaters out of enclosed spaces (the same discipline as for CO), waiting and ventilating before re-entering a blasted area, and treating any brown-fume or “not-quite-right after fumes” report as a reason for medical evaluation because the lung reaction is delayed.
Key takeaways
- NO₂ from welding, engines, heaters, and blasting is only mildly irritating at first, then causes delayed pulmonary edema.
- Keep engines/gas heaters out of enclosed spaces and ventilate; wait and ventilate before re-entering blasted areas.
- Treat brown-fume exposure or feeling off after fumes as urgent — the lung injury shows up hours later.
Field guidance for planning and training, not a substitute for the manufacturer Safety Data Sheet, which gives the exposure limits, PPE, and handling for your specific product.
OSHA Exposure Limits
OSHA permissible exposure limit (PEL) and secondary limit for Nitrogen Dioxide on a US construction site. Where a substance-specific 1926 standard applies, its codified limit is shown; otherwise the figure comes from Table 1 to 29 CFR 1926.55, the construction air-contaminants table. Where Table 1 gives no figure, either the substance has its own standard (the row says "see 1926.xxxx" and this page names that standard) or Table 1 sets no limit for it. In both cases Section 8 of the Safety Data Sheet lists the limits other bodies recommend and the supplier's controls.
| Limit | Value | Basis / citation |
|---|---|---|
| OSHA PEL (ceiling) | (C) 5 ppm (9 mg/m³) | 29 CFR 1926.55 Table 1OSHA entry: Nitrogen dioxide |
| Action level | See SDS / standard | Not all substances define an action level |
| Averaging period | ceiling | A ceiling is never averaged: it must not be exceeded at any moment of the shift. The ACGIH TLV and NIOSH REL are recommendations; some are lower than the PEL |
This limit is a ceiling. Exposure must at no time exceed it. Where instantaneous monitoring is not feasible, 29 CFR 1926.55(a)(1) lets the employer assess the ceiling as a 15-minute time-weighted average, one that still may not be exceeded at any time during the working day.
Many OSHA PELs date to 1971 and may be less protective than current ACGIH/NIOSH values; always check Section 8 of the manufacturer SDS for the limits it lists, which can be lower than the PEL, and for its control guidance. Not legal advice.
GHS Classification
Physical Properties
A product sold under this name can differ in concentration or form; its own SDS gives its values.
Where Nitrogen Dioxide shows up on the job
Trades that commonly handle Nitrogen Dioxide, each with an OSHA HazCom guide built for the chemicals and tasks on that kind of site:
OSHA & HazCom Compliance Requirements
For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Where a product your crews use contains Nitrogen Dioxide and is a hazardous chemical under the standard (its supplier's label and SDS say so), the employer must:
- •Maintain an accessible SDS for Nitrogen Dioxide (readily accessible during each work shift, 29 CFR 1910.1200(g)(8))
- •Keep the supplier's label on shipped containers (29 CFR 1910.1200(f)(1)) and mark workplace containers with the shipped-label elements or the product identifier and hazard information (29 CFR 1910.1200(f)(6)); a portable container for immediate use by the person who filled it needs none (1910.1200(f)(8))
- •Include it in the workplace chemical inventory
- •Train employees on hazards before initial assignment
- •Retain employee exposure and medical records per 29 CFR 1910.1020: exposure records for at least 30 years, medical records for the duration of employment plus 30 years. An SDS itself may be discarded if a record of the chemical's identity, where it was used and when is kept for 30 years
HazCom (1910.1200 / construction 1926.59) covers hazard classification, labels, SDSs, the written program (with its chemical list and the rules for non-routine tasks and multi-employer sites) and training. It does not impose chemical storage segregation. Flammable & combustible liquid storage for construction is 29 CFR 1926.152; segregation of incompatibles is planned from SDS Sections 7 and 10. Exemptions apply, such as a consumer product used the way a consumer would use it (1910.1200(b)(6)(ix)). Not legal advice; state-plan states may have stricter rules.
Handling & Secondary-Container Labeling
When you transfer Nitrogen Dioxide into a workplace (secondary) container, OSHA gives two compliant options under 29 CFR 1910.1200(f)(6):
- •(f)(6)(i): full GHS label elements (as on the shipped container)
- •(f)(6)(ii): product identifier + words/pictures/symbols (or combination) that provide AT LEAST general information on the hazards and, with the other information immediately available under the HazCom program, the specific hazards
There is no volume/size cutoff for secondary containers: the ≤100 ml / ≤3 ml accommodations (29 CFR 1910.1200(f)(12) (added by the HCS 2024 final rule)) apply only to the manufacturer's shipped container. A portable container filled for the immediate use of the worker who fills it needs no label (29 CFR 1910.1200(f)(8)).
GHS Hazard Classification under OSHA HCS
OSHA's Hazard Communication Standard adopts the GHS (primarily GHS Revision 7 (HCS 2024)). It uses 8 hazard pictograms (Appendix C, Figure C.1); a label carries only the ones its classification calls for. The Environment pictogram (GHS09) is not required by OSHA. Not in App C; outside OSHA jurisdiction; voluntary.
The eight HCS pictograms:
For flammable liquids, OSHA classifies by flash point and boiling point (App B.6.1 / 1910.106(a)):
- •Category 1: FP < 73.4°F AND BP <= 95°F
- •Category 2: FP < 73.4°F AND BP > 95°F
- •Category 3: FP >= 73.4°F AND <= 140°F
- •Category 4: FP > 140°F AND <= 199.4°F
The GHS classification of a product that contains Nitrogen Dioxide comes from Section 2 of that product's Safety Data Sheet: the pictograms and categories on your labels follow that section.
HCS 2024 Update Deadlines
Under the federal Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7):
- •May 19, 2026: manufacturers, importers, and distributors of Nitrogen Dioxide sold as a substance update its labels & SDSs (1910.1200(j)(2)(i))
- •November 20, 2026: for the substance, employers, as necessary, update alternative workplace labels, the written program & training for newly identified hazards (1910.1200(j)(2)(ii))
- •For a mixture that contains Nitrogen Dioxide: November 19, 2027 for manufacturers, importers and distributors, and May 19, 2028 for employers, as necessary (1910.1200(j)(3))
During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both. These are the federal OSHA dates; State Plans adopt the update on their own schedules, so check your state.
Quick Actions
Put Nitrogen Dioxide on your written inventory, print the workplace label your containers need, and keep your supplier’s sheet reachable on the jobsite.
The safety data sheet for your product comes from the supplier who sold it to you. No public registry can provide it. For the underlying chemistry, the public record is on PubChem.
Where this fits in your HazCom program
- SDS management: collecting the sheet, keeping it current, and making it readable during each work shift.
- GHS labels & workplace labeling: what has to appear on the shipped container, and what a secondary container needs instead.
Free Compliance Tools for Nitrogen Dioxide
Also on a welding & metalwork job
Frequently Asked Questions
What is Nitrogen Dioxide (CAS 10102-44-0)?
Oxidizer and pollutant
What are the OSHA HazCom requirements for Nitrogen Dioxide on a construction site?
For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Where a product you use containing Nitrogen Dioxide is a hazardous chemical under the standard (its supplier's label and SDS say so), you must keep its Safety Data Sheet accessible, keep the supplier's label on shipped containers and label workplace containers under (f)(6), list it in the written program's chemical inventory, and train workers on its hazards at initial assignment. Exemptions apply, such as a consumer product used the way a consumer would use it (1910.1200(b)(6)(ix)).
What is the OSHA permissible exposure limit (PEL) for Nitrogen Dioxide?
OSHA lists Nitrogen Dioxide in 29 CFR 1926.55 Table 1 under the entry "Nitrogen dioxide", at (C) 5 ppm (9 mg/m³), a ceiling, which applies at every moment and is not an average. Section 8 of the manufacturer Safety Data Sheet lists the exposure limits the supplier reports and its control advice; the limit OSHA enforces is the one in its standard, and a State Plan may set its own.
When does the updated HCS 2024 labeling apply to Nitrogen Dioxide?
Under the federal Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7), manufacturers, importers and distributors must comply by May 19, 2026 when Nitrogen Dioxide is sold as a substance, and by November 19, 2027 for mixtures that contain it. Employers must, as necessary, update alternative workplace labels, the written program and training for newly identified hazards by November 20, 2026 for substances and May 19, 2028 for mixtures (29 CFR 1910.1200(j)). During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both. State Plans adopt the update on their own schedules, so check your state's dates.
How do I label a secondary (workplace) container of Nitrogen Dioxide?
Under 29 CFR 1910.1200(f)(6) you have two options: (i) the label elements of (f)(1)(i) through (v): product identifier, signal word, hazard statements, pictograms and precautionary statements, with no supplier name or address needed, or (ii) the product identifier plus words, pictures, symbols, or a combination that provide at least general hazard information and that, with the other information immediately available to workers under the HazCom program, give the specific hazards. There is no volume/size cutoff for secondary containers. A portable container filled from a labeled container, kept under the control of the worker who fills it and used only by that worker within the same shift, does not require a label (29 CFR 1910.1200(f)(8)).
How long must SDS and exposure records for Nitrogen Dioxide be kept?
Under 29 CFR 1910.1020, 30-year retention applies to employee exposure and medical records (medical records: duration of employment plus 30 years), not to SDSs generically. Where an SDS is not retained, a record of the chemical's identity, where it was used, and when must be kept for at least 30 years.
Where can I find the SDS for Nitrogen Dioxide?
Under 29 CFR 1910.1200(g)(6) and (g)(7), the manufacturer or importer of Nitrogen Dioxide must ensure that distributors and employers receive its Safety Data Sheet with the initial shipment and with the first shipment after the sheet is updated, and a distributor passes it on in its commercial shipments the same way. Retail and wholesale distributors that sell to employers over the counter or to commercial accounts have their own duties in (g)(7)(iii) to (vii), such as providing the sheet on request. HazComFast keeps the sheets you collect in one inventory per jobsite, searchable by product, manufacturer or CAS number, and your jobsite's SDS load onto the phone on their own.
Sources & Primary References
Regulatory data on this page comes from 29 CFR 1926.59 / 1910.1200 and substance-specific 1926 standards, last verified October 19, 2026 against eCFR, OSHA.gov, and the Federal Register. Physical-property data comes from PubChem; the source of a figure is in parentheses after it where one is given (NIOSH Pocket Guide, ICSC, or the dataset PubChem cites). Confirm it against the manufacturer Safety Data Sheet. This page is informational and is not legal advice.
Get the Binder in Order Before the Inspector Arrives. Are You Ready?
OSHA inspections come unannounced, apart from the few exceptions listed in 29 CFR 1903.6. Get the binder in order before the opening conference, not during it.
Serious Violation
$16,550
per violation (max)
HazComFast Pro
$199/mo
10 jobsites, unlimited chemicals, unlimited workers
New sign-ups are paused. The free tools below need no account, and customers can log in as usual.