Styrene

Styrene (CAS 100-42-5) — Monomer for polystyrene and resins. Get the SDS and OSHA HazCom guidance you need to store, label, and handle it safely on the job site.

Verified vs OSHA sources · October 5, 2026

CAS Registry Number CAS 100-42-5 · also known as Vinylbenzene, Phenylethene

Overview

Monomer for polystyrene and resins

Synonyms:VinylbenzenePhenylethene

Styrene on the job site

Styrene is the reactive solvent-monomer in polyester and vinyl-ester resins — fiberglass (FRP) layup and spray, cultured marble, tank and pool linings, and some coatings. Open resin work and spraying release a lot of vapor with a strong, sweet odor, and exposure climbs quickly past the 100 ppm PEL during hand layup and especially spray application in an enclosed area. It's a CNS depressant (headache, dizziness, the “styrene sickness” after a heavy day), a possible carcinogen, and there is concern for hearing (it's ototoxic, worse with noise).

Ventilation is the primary control — general plus local exhaust at the layup or spray station — with respiratory protection for spraying and skin/eye protection (styrene irritates and defats skin). Because it's flammable, ignition control and covered rag storage apply. Rotating workers out of enclosed FRP work limits both the CNS effects and the cumulative dose.

Key takeaways

  • FRP layup and spray push styrene past 100 ppm fast — CNS effects, possible carcinogen, and ototoxic with noise.
  • Control with general + local exhaust, respirator for spraying, and skin/eye protection.
  • It's flammable — control ignition, and rotate crews out of enclosed resin work.

Field guidance for planning and training — not a substitute for the manufacturer Safety Data Sheet, which controls the exposure limit, PPE, and handling for your specific product.

OSHA Exposure Limits

OSHA permissible exposure limit (PEL) and secondary limit for Styrene on a US construction site. Where a substance-specific 1926 standard applies, its codified limit is shown; otherwise the figure comes from Table 1 to 29 CFR 1926.55, the construction air-contaminants table. Where 1926.55 does not list the substance, the Safety Data Sheet (Section 8) controls.

LimitValueBasis / citation
OSHA PEL (ceiling)(C) 100 ppm29 CFR 1926.55 Table 1
Action levelSee SDS / standardNot all substances define an action level
Averaging periodceilingA ceiling is never averaged: it must not be exceeded at any moment of the shift. Compare with ACGIH TLV / NIOSH REL — often more protective than the OSHA PEL

This limit is a ceiling. Exposure must at no time exceed it. Where instantaneous monitoring is not feasible, 29 CFR 1926.55(a)(1) lets the employer assess the ceiling as a 15-minute time-weighted average — one that still may not be exceeded at any time during the working day.

Many OSHA PELs date to 1971 and may be less protective than current ACGIH/NIOSH values; always check the manufacturer SDS (Section 8) for the controlling limit and engineering-control guidance. Not legal advice.

GHS Classification

The manufacturer or importer of Styrene (CAS 100-42-5) classifies its hazards (29 CFR 1910.1200(d)(1)). You'll find them in Section 2, Hazard(s) identification, of the manufacturer's Safety Data Sheet (29 CFR 1910.1200(g)(2)(ii)).

Physical Properties

Molecular FormulaC8H8
Molecular Weight104.15
Boiling Point293 to 295 °F at 760 mmHg (NTP, 1992)
Melting Point-24 to -23 °F (NTP, 1992)
Flash Point88 °F (NTP, 1992)
Density0.906 at 68 °F (USCG, 1999) - Less dense than water; will float
Vapor Pressure4.3 mmHg at 59 °F ; 9.5 mmHg at 86 °F; 10 mmHg at 95 °F (NTP, 1992)
Solubilityless than 1 mg/mL at 66 °F (NTP, 1992)

Where Styrene shows up on the job

Trades that commonly handle Styrene, each with an OSHA HazCom guide built for the chemicals and tasks on that kind of site:

OSHA & HazCom Compliance Requirements

For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Employers who use Styrene must:

  • •Maintain an accessible SDS for Styrene (readily accessible during each work shift, 29 CFR 1910.1200(g)(8))
  • •Label all containers with GHS-compliant labels (29 CFR 1910.1200(f)(1) shipped / 29 CFR 1910.1200(f)(6) workplace)
  • •Include it in the workplace chemical inventory
  • •Train employees on hazards before initial assignment
  • •Retain employee exposure and medical records per 29 CFR 1910.1020 — 30-year retention applies to exposure/medical records, not to SDSs generically

HazCom (1910.1200 / construction 1926.59) covers labels, SDSs, and training only — it does not impose chemical storage segregation. Flammable & combustible liquid storage for construction is 29 CFR 1926.152; segregation of incompatibles is planned from SDS Sections 7 and 10. Not legal advice; state-plan states may have stricter rules.

Handling & Secondary-Container Labeling

When you transfer Styrene into a workplace (secondary) container, OSHA gives two compliant options under 29 CFR 1910.1200(f)(6):

  • •(f)(6)(i): full GHS label elements (as on the shipped container)
  • •(f)(6)(ii): product identifier + words/pictures/symbols (or combination) that provide AT LEAST general information on the hazards

There is no volume/size cutoff for secondary containers — the ≤100 ml / ≤3 ml accommodations (29 CFR 1910.1200(f)(12) (added by the HCS 2024 final rule)) apply only to the manufacturer's shipped container. A portable container filled for the immediate use of the worker who fills it needs no label (29 CFR 1910.1200(f)(8)).

GHS Hazard Classification under OSHA HCS

OSHA's Hazard Communication Standard adopts the GHS (primarily GHS Revision 7 (HCS 2024)). It requires 8 hazard pictograms (Appendix C, Figure C.1). The Environment pictogram (GHS09) is not required by OSHA — Not in App C; outside OSHA jurisdiction; voluntary.

The 8 OSHA-required pictograms:

FlameFlame Over CircleExclamation MarkExploding BombCorrosionGas CylinderHealth HazardSkull and Crossbones

For flammable liquids, OSHA classifies by flash point and boiling point (App B.6.1 / 1910.106(a)):

  • •Category 1: FP < 73.4°F AND BP <= 95°F
  • •Category 2: FP < 73.4°F AND BP > 95°F
  • •Category 3: FP >= 73.4°F AND <= 140°F
  • •Category 4: FP > 140°F AND <= 199.4°F

The specific GHS classification of Styrene comes from its Safety Data Sheet (Section 2). Use the live classification panel above and the manufacturer SDS to confirm pictograms and categories.

HCS 2024 Update Deadlines

Under the Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7):

  • •May 19, 2026 — manufacturers, importers, and distributors update substance labels & SDSs (1910.1200(j)(2)(i))
  • •November 20, 2026 — employers update workplace labeling, the written program & training (1910.1200(j)(2)(ii))

During the interim, parts may comply with the 2012 HCS, the 2024 HCS, or both.

Quick Actions

Put Styrene on your written inventory, print the workplace label your containers need, and keep your supplier’s sheet reachable on the jobsite.

The safety data sheet for your product comes from the supplier who sold it to you — no public registry can provide it. For the underlying chemistry, the public record is on PubChem.

Where this fits in your HazCom program

  • SDS management — collecting the sheet, keeping it current, and making it readable during each work shift.
  • GHS labels & workplace labeling — what has to appear on the shipped container, and what a secondary container needs instead.

Frequently Asked Questions

What is Styrene (CAS 100-42-5)?

Monomer for polystyrene and resins

What are the OSHA HazCom requirements for Styrene on a construction site?

For construction work, Hazard Communication is governed by 29 CFR 1926.59 (adopts 29 CFR 1910.1200). Employers who use Styrene must maintain an accessible Safety Data Sheet (SDS), label containers with GHS-compliant labels, include the chemical in the workplace chemical inventory, and train workers on its hazards before initial assignment.

What is the OSHA permissible exposure limit (PEL) for Styrene?

OSHA's permissible exposure limit for Styrene is (C) 100 ppm (ceiling), per 29 CFR 1926.55 Table 1. (C) 420 mg/m³ — never to be exceeded at any time; no TWA and no peak allowance in construction. Where the ACGIH TLV or NIOSH REL is more protective, follow the lower value, and confirm the limit for your specific task against Section 8 of the manufacturer Safety Data Sheet.

When does the updated HCS 2024 labeling apply to Styrene?

Under the Hazard Communication Standard 2024 update (aligned primarily GHS Revision 7), chemical manufacturers, importers, and distributors must update substance labels and SDSs by May 19, 2026, and employers must update workplace labeling, the written program, and training for substances by November 20, 2026. During the interim, parties may comply with the 2012 HCS, the 2024 HCS, or both.

How do I label a secondary (workplace) container of Styrene?

Under 29 CFR 1910.1200(f)(6) you have two options: (i) the full GHS label elements as on the shipped container, or (ii) the product identifier plus words, pictures, symbols, or a combination that provide at least general hazard information. There is no volume/size cutoff for secondary containers. A portable container filled for the immediate use of the worker who fills it does not require a label (29 CFR 1910.1200(f)(8)).

How long must SDS and exposure records for Styrene be kept?

Under 29 CFR 1910.1020, 30-year retention applies to employee exposure and medical records (medical records: duration of employment plus 30 years) — not to SDSs generically. Where an SDS is not retained, a record of the chemical's identity, where it was used, and when must be kept for at least 30 years.

Where can I find the SDS for Styrene?

Under 29 CFR 1910.1200(g)(6) and (g)(7), the manufacturer, importer or distributor that sold you Styrene must send its Safety Data Sheet with the first shipment, and again with the first shipment after the sheet is updated. HazComFast keeps the sheets you collect in one inventory per jobsite, searchable by product, manufacturer or CAS number, and your jobsite's SDS load onto the phone on their own.

Regulatory data on this page is sourced from HazComFast's verified regulatory module (29 CFR 1926.59 / 1910.1200 and substance-specific 1926 standards), last verified October 5, 2026 against eCFR, OSHA.gov, and the Federal Register. Physical-property data comes from PubChem. Confirm it against the manufacturer Safety Data Sheet. This page is informational and is not legal advice.

Looking for more chemicals?

Browse our database of industrial chemicals with GHS data, safety information, and compliance tools.

Get the Binder in Order Before the Inspector Arrives. Are You Ready?

OSHA does not give advance notice of inspections (29 CFR 1903.6). Get the binder in order before the opening conference, not during it.

Serious Violation

$16,550

per violation (max)