Can a confined space entrant ask for the space to be re-evaluated?
Yes. Under 29 CFR 1910.146(d)(5)(v) in general industry and 1926.1204(e)(5) in construction, the employer has to re-evaluate a permit space in the presence of the authorized entrant, or that employee's authorized representative, who asks. The trigger differs: “reason to believe” the evaluation may not have been adequate in general industry, “some indication” of it in construction. Neither standard sets a deadline, and neither makes the request alone a reason to stop entry.

Is Exactly 10% LEL Safe? OSHA's Definition Says One Thing, Its Guidance Another
OSHA's definition says a hazardous atmosphere is flammable gas 'in excess of 10 percent' of the LEL, so 10.0% reads as acceptable. OSHA's enforcement directive, its model appendices and its shipyard rule treat it the other way. This article sets out the verbatim texts, which of them bind and which only guide, and what to write in your program.

Confined Space Entry: OSHA Permit-Required Guide for Construction
Complete guide to confined space entry in construction under 29 CFR 1926 Subpart AA. Covers permit-required vs non-permit spaces, atmospheric testing order, the entry permit, rescue duties, multi-employer coordination, and the citation traps that get contractors fined.