Lead had the largest number of retained results above a current federal eight-hour exposure reference: 108 results across 56 OSHA inspections. Chromium(VI), cadmium and respirable crystalline silica followed. This comparison uses personal air-sampling results dated 2014-2025 and general-industry PEL values checked November 17, 2026.
These are numerical comparisons with a consistent set of reference values, not findings of historical OSHA violations. The analysis retains positive, unqualified results that meet the selection rules below. It excludes nondetects rather than treating them as zero. Its percentages therefore describe the retained positive results, not all OSHA samples or the U.S. workforce.
Which substances had the most results above the reference?
The named-substance panel contains 1,402 retained results in 62 categories. Of those results, 256 were numerically above their assigned reference. They came from 127 distinct inspection identifiers. An inspection can contribute results for several substances or several sampling assessments.
| Reported substance or category | Retained positive results | Above reference | Share of retained positives | Inspections with an above-reference result |
|---|---|---|---|---|
| Lead, inorganic (as Pb) | 283 | 108 | 38.2% | 56 |
| Cadmium | 73 | 29 | 39.7% | 16 |
| Chromium(VI) (as CrVI) | 162 | 29 | 17.9% | 17 |
| Silica, respirable crystalline (mixed) | 40 | 22 | 55.0% | 18 |
| Copper fume (as Cu) | 345 | 19 | 5.5% | 15 |
| Arsenic, inorganic (as As) | 49 | 11 | 22.4% | 6 |
| Carbon Dioxide | 13 | 7 | Not shown (n < 30) | 2 |
| Methylene Chloride | 13 | 6 | Not shown (n < 30) | 4 |
| Beryllium and compounds (as Be) | 5 | 4 | Not shown (n < 30) | 3 |
| Formaldehyde | 24 | 4 | Not shown (n < 30) | 4 |
The table is ordered by the number above the reference, with alphabetical ordering for ties. Percentages are shown only when a category has at least 30 retained results. That display threshold limits emphasis on small groups; it does not establish statistical representativeness. Inspection counts overlap between rows and must not be added to estimate a total.
The complete results table includes every assigned category, including those with no retained result above its reference. The workbook connects the summary to its retained records and inspection groups.
Count, percentage and inspection coverage answer different questions
Lead accounted for 108 of the 256 above-reference results in the named-substance panel, across 56 inspections. Among named categories with at least 30 retained results, respirable crystalline silica has the largest above-reference share: 22 of 40, or 55.0%.
That silica percentage has a narrow denominator. It excludes nondetects, qualified values, records without a unique eight-hour-calculation result and records that cannot be matched to the reference unit. It cannot be read as the percentage of silica-exposed workers above a PEL, or even the percentage of all silica samples in the source files above a PEL.
Repeated sampling also matters. Two above-reference results from one inspection are two results but one inspection identifier. Different identifiers need not represent different establishments, and none identifies a unique worker. The inspection column makes some of this concentration visible without inventing a workforce denominator.
Generic dust results are a separate comparison
The two PNOR-coded categories contribute 2,841 retained results and 163 numerical exceedances of the generic mass references. They are shown separately from named substances.
| Reported dust category | Federal reference used | Retained positive results | Above reference | Inspections with an above-reference result |
|---|---|---|---|---|
| PNOR, total dust | 15 mg/m3 | 945 | 86 | 57 |
| PNOR, respirable fraction | 5 mg/m3 | 1,896 | 77 | 63 |
PNOR means particulates not otherwise regulated. The assigned total-dust and respirable-fraction values are 15 and 5 mg/m3 under Table Z-1. The fraction is part of the reference: total dust and respirable dust are not interchangeable measurements.
A PNOR code does not demonstrate that a dust contains no silica, lead or other substance with its own limit. Generic gravimetric results without a verified fraction are excluded instead of being assigned 15 mg/m3 automatically. A fused-silica entry that cites a PNOR fallback is also excluded from the named-substance ranking. Marble remains in that ranking because Table Z-1 names it and the retained code specifies total dust.
What the reference values mean
This study uses current federal general-industry eight-hour time-weighted-average values as a common comparison basis. It does not determine which industry standard, jurisdiction, exception or historical rule applied to each sampled operation. Applying the same reference to records from different years permits a numerical comparison; it does not recreate an enforcement decision.
The leading categories use these values:
| Reported category | Eight-hour reference used | Federal standard |
|---|---|---|
| Inorganic lead, as Pb | 0.05 mg/m3 | 1910.1025 |
| Chromium(VI), as CrVI | 0.005 mg/m3 | 1910.1026 |
| Cadmium | 0.005 mg/m3 | 1910.1027 |
| Inorganic arsenic, as As | 0.01 mg/m3 | 1910.1018 |
| Respirable crystalline silica | 0.05 mg/m3 | 1910.1053 |
| Beryllium and compounds, as Be | 0.0002 mg/m3 | 1910.1024 |
The chromium(VI), cadmium, arsenic, silica and beryllium standards state their PELs in micrograms per cubic meter. The table converts those values to milligrams per cubic meter by dividing by 1,000. No gas concentration was converted between ppm and mg/m3, and no elemental result was converted into an oxide concentration.
The PEL is distinct from an action level. A result at or below the reference does not by itself establish that no exposure assessment, training, medical surveillance or other requirement applies. Ceiling and short-term limits require their own comparisons. An eight-hour result cannot establish compliance with those limits, and this study does not combine exposures into a mixture calculation under 1910.1000.
Silica and beryllium requirements changed during the sampling period. The study applies the stated current values to earlier results without labeling them violations of rules in force at that time. OSHA also cautions that many federal PELs are outdated; being below one is not proof of an absence of health risk. The annotated PEL tables explain that limitation. Recommended limits are outside this study's comparison panel.
Selecting samples for comparison
The source is OSHA's Chemical Exposure Health Data: 13 annual download archives labeled 2014 through 2026. The study selects samples by the date they were taken, from January 1, 2014 through December 31, 2025. Some earlier samples appear in the 2026 archive. Samples actually taken in 2026 are excluded.
| Selection step | Records or categories |
|---|---|
| Parsed source records, across all archives | 543,110 |
| Source records within the sampling-date window | 509,374 |
| Distinct analytical versions after identical repeats were collapsed | 502,429 |
| Stable personal, nonblank records after conflicting identities were excluded | 277,991 |
| Those records marked Y for eight-hour TWA calculation | 45,707 |
| Unique Y result within inspection, sampling number and substance code, with complete grouping keys | 25,523 |
| Final named-substance results | 1,402 |
| Final PNOR results, kept separate | 2,841 |
Two malformed records could not be read into the expected fields and are excluded. Deduplication counts cover only records within the date window. The intermediate rows show successive filters; the final two rows divide the retained results into named substances and PNOR.
Repeated and conflicting records
A sample's analytical identity combines its inspection number, sampling number, field number, laboratory number, normalized substance code and sampling date. Its analytical details are the result, unit, qualifier, sampling duration, volume, weight, sample type, blank flag and TWA-calculation flag. Identical analytical records in different archives count once. A change to an administrative name alone does not create another version.
This removes 6,945 repeats. Another 115 identities have conflicting analytical details, so every version of those identities is excluded. The public files give no revision rule for deciding which conflicting version to keep.
Numeric substance codes are padded to four digits: 560 and 0560 become the same code. Commas used as padding at either end of older qualifier fields are removed; meaningful qualifier tokens remain. Source-file and record identifiers distinguish the observations.
The eight-hour flag
OSHA's field dictionary says Y means an eight-hour TWA calculation was used. It does not establish that sampling lasted 480 minutes. A sampling number can cover several collection media, so a row cannot be assumed to represent a separate worker or a full shift.
The main comparison requires exactly one Y result per inspection, sampling number and analyte group. Groups with several Y records are excluded; their values are not averaged, added or reduced to the highest result. The two beryllium codes are checked together as one analyte family. Y values have already been calculated, so they are not adjusted again for sampling minutes or eight hours. Unflagged media results are not used to construct assumed full-shift exposures.
Concentrations and reference values
Retained concentrations must be finite, greater than zero and free of substantive qualifiers. ND, upper-bound, approximate and other qualified values are excluded. Nondetects are not assigned zero or half a detection limit. The percentages therefore describe positive, unqualified results in the retained group, not the frequency of exposure across all samples.
Unit M is treated as mg/m3 and unit P as ppm. Sample masses, percentages, biological results and unsupported units are excluded. Each code also needs a federal eight-hour reference in the reported unit. A result counts as above the reference only when it is strictly greater. Sampling and analytical uncertainty are not included in that numerical comparison.
Chemical form and measurement basis must match the reference. Elemental iron is not automatically compared with the iron-oxide PEL, or elemental zinc with the zinc-oxide-fume PEL. A CrO3 entry needs a verified compatible basis before comparison with a CrVI limit. Particle-count limits are not converted to dust mass limits. Entries with ceiling-only, sector-specific, composition-dependent or unresolved references are documented outside the retained group.
What an SDS can and cannot resolve
Appendix D to 1910.1200 requires exposure-limit information in SDS Section 8, including applicable OSHA PELs and specified additional limits. That section is a starting reference for a product, not a measurement of an employee's exposure during a task.
For a laboratory report, the useful match is the analyte, its chemical form, the sampled fraction, the concentration unit and the averaging basis. A lead result expressed as Pb and a respirable-dust result require different reference entries even when they come from the same operation. The exposure-limit guide explains PEL, TLV and other limit types; the SDS reading guide covers the document's sections.
The companion comparison with NIOSH and California limits addresses a different question: how selected results compare with other exposure benchmarks. The present study uses one federal reference framework across a broader category inventory. Its counts should not be combined with that companion study, which has different eligibility and mapping rules.
Coverage of the public data
The inventory includes all 470 normalized substance codes left after blank, nonpersonal and conflicting records are removed. Of these, 106 have a positive, unqualified concentration with a single Y result in one of the unit families considered. The reference table assigns 65 code-and-unit entries to 64 categories: 62 named categories and two generic PNOR categories. A code with no retained result may still have a PEL and may still involve workplace exposure.
OSHA describes these data as results from closed inspections; open or contested cases may be withheld. Enforcement sampling often targets higher or worst-case exposures. It is not a random sample of U.S. workers. Inspection priorities, release dates and repeated sampling all affect the results available, and later releases may add samples taken in 2025. The extract cannot estimate national exposure prevalence or establish a causal trend.
The ranking depends on which results meet the selection rules and have compatible references. It does not rank toxicity, disease burden, short-term hazards or employer performance. Assessing an operation also requires its sampling design, analytical uncertainty and applicable standard. OSHA's air-sampling technical guidance explains those issues.
Reference sources
Federal references are assigned using the linked provisions and each analyte's chemical form, sampled fraction and reported unit. A similar chemical name is not enough for a match. The source data were available on November 16, 2026; the federal reference values are dated November 17, 2026.
Federal OSHA penalty limits were last checked against the eCFR, OSHA.gov and the Federal Register on October 19, 2026, and HCS transition dates on June 23, 2026. Last reviewed November 18, 2026.
About This Article
Published by: HazComFast
Published: November 17, 2026
Last Updated: November 18, 2026