Six of the 13 supplier safety data sheets in this pilot explicitly identified HCS 2024. Among the nine documents describing liquids, three reported numerical dynamic viscosity and none reported numerical kinematic viscosity in Section 9. The records are November 18, 2026, document snapshots. They do not measure the proportion of U.S. SDS that comply with OSHA's standard.
The panel contains six Fisher Chemical SDS, six Flinn Scientific SDS and one MilliporeSigma SDS. This audit compares their displayed dates, HCS-edition wording and selected physical-property entries. It does not test the chemicals, inspect workplaces or determine whether the documents satisfy every applicable requirement.
What the supplier documents stated
All six Fisher documents explicitly referred to OSHA's Hazard Communication Standard 2024 and carried a December 18, 2025, revision date. The Sigma acetone SDS named OSHA HCS without identifying an edition. The six Flinn documents did not state an HCS-edition year in the supplier documents.
| Supplier | Documents | HCS-edition wording observed |
|---|---|---|
| Fisher Chemical | 6 | Explicitly identified HCS 2024 |
| Flinn Scientific | 6 | No edition year stated |
| MilliporeSigma | 1 | OSHA HCS named without an edition year |
The six references came from one supplier and shared a revision date and template. Their presence does not establish compliance, and the absence of a year does not establish that another sheet is obsolete. Neither 29 CFR 1910.1200(g)(2) nor Appendix D requires the literal phrase "HCS 2024" as a separate SDS field. The required content still needs to be assessed. OSHA standard and Appendix D.
A print date must be kept separate from a revision date. The retained Sigma acetone document displayed a November 18, 2026, print date and a September 6, 2024, revision date. Printing the file in 2026 did not establish a 2026 technical revision. Section 16 of Appendix D calls for the date of preparation or last revision; an additional print date answers a different question. Appendix D, Section 16.
Particle entries and physical form
Six SDS had a dedicated particle-characteristics entry. Four marked it not applicable, and two stated that information was unavailable. Two other documents described the solid's form under appearance: Flinn sodium chloride as crystalline powder and Flinn solid sodium hydroxide as pellets or flakes. These descriptions were retained as qualitative physical form rather than counted as numerical particle-size measurements.
| Particle information observed | Documents | Interpretation in this audit |
|---|---|---|
| Explicitly not applicable | 4 | The supplier's statement, without an independent adequacy judgment |
| Explicitly unavailable | 2 | An express statement that data were unavailable |
| Qualitative physical form | 2 | Powder, pellets or flakes; no numerical size value |
| No particle entry or description found | 5 | Silence in the complete Section 9 fields reviewed |
The four solid-product SDS were split between two explicit unavailable-data statements and two qualitative form descriptions. None of the 13 documents stated a numerical particle-size value in Section 9. A physical-state label by itself was not coded as particle information.
The 2024 rule added particle characteristics to Section 9 of Appendix D. OSHA's preamble explains that particle information is expected where available and appropriate, without creating an obligation to test for unknown properties. Particle information can also be relevant to solids dispersed in a liquid. The label "liquid" does not by itself justify a not-applicable entry. Conversely, the absence of a measured particle-size value is not enough to establish a violation. This pilot records the statements; it does not determine whether each supplier had supplied all available, appropriate information. 2024 final rule, discussion of Section 9.
Viscosity statements by physical state
The nine liquid SDS and four solid SDS require separate denominators. A combined count would place explicit not-applicable statements for solids alongside entries for liquids.
| Viscosity statement | Liquid SDS (n = 9) | Solid SDS (n = 4) |
|---|---|---|
| Numerical value in dynamic units | 3 | 0 |
| Generic viscosity entry: data unavailable | 3 | 0 |
| Generic viscosity entry: not applicable | 0 | 2 |
| No viscosity statement found | 3 | 2 |
The three numerical values were 0.32 mPa·s at 20 °C for Fisher acetone, 2.27 mPa·s at 20 °C for Fisher isopropanol and 2.038 mPa·s at 25 °C for Flinn isopropanol. The values and temperatures were transcribed without conversion or added precision. Products and temperatures differ, so these numbers are not a controlled comparison between suppliers.
The units identify dynamic viscosity: mPa·s and cP express dynamic viscosity, while mm²/s and cSt express kinematic viscosity. None of the nine liquid SDS stated a numerical kinematic-viscosity value in Section 9. Dynamic values are not converted to kinematic viscosity; generic statements remain unclassified by viscosity type. NIST conversion factors.
Appendix D names kinematic viscosity. Under 29 CFR 1910.1200(g)(3), when no relevant information is found for a required subheading within an SDS section, the preparer must mark that subheading to indicate that no applicable information was found. A dynamic-viscosity value cannot simply be recorded as a measured kinematic-viscosity value. An unavailable-data statement, a not-applicable statement and an omitted entry also convey different information. A query to the supplier needs to distinguish these cases before addressing whether the entry meets the requirement. Section 1910.1200(g) and Appendix D, Section 9.
The federal transition dates
The extended federal schedule in force on the document-snapshot date assigned different dates to suppliers and employers, and to substances and mixtures. The original 2024 schedule had been extended in January 2026.
| Responsible party and material | Extended federal date |
|---|---|
| Manufacturers, importers and distributors evaluating substances under paragraph (j)(2)(i) | May 19, 2026 |
| Employers: necessary workplace-label, HazCom-program and additional-training changes for substances | November 20, 2026 |
| Manufacturers, importers and distributors evaluating mixtures under paragraph (j)(3)(i) | November 19, 2027 |
| Employers: necessary workplace-label, HazCom-program and additional-training changes for mixtures | May 19, 2028 |
The snapshot was taken on November 18, 2026: after the substance supplier deadline and two days before the substance employer deadline. Those dates describe different duties. They are not universal SDS expiration dates, and a document's revision date cannot establish whether every applicable change was necessary or completed. State Plan implementation was not individually audited. Current paragraph (j) and January 2026 extension. The HCS transition-date tool and HCS 2024 calendar present the schedule by role and material.
The selection labels "neat reagent target" and "aqueous solution" are not legal substance/mixture determinations. Only the Sigma acetone document explicitly used a substance designation. Four aqueous-solution compositions supported a mixture classification. For eight documents, the legal type was not independently established. Multiple ingredients can include an impurity; a single CAS entry does not settle every classification question. The Fisher solid sodium hydroxide composition, for example, listed sodium hydroxide and sodium carbonate. This audit did not decide whether that carbonate was an impurity or a mixture component.
The absence of an express substance/mixture designation was not coded as a defect. Nor was a voluntarily supplied document for a product described as nonhazardous, such as the Fisher sodium chloride SDS, put into a mandatory-compliance denominator.
Documents and checks
The study uses November 18, 2026, snapshots of 13 U.S. SDS from Fisher Chemical, Flinn Scientific and MilliporeSigma. The six product families are acetone, isopropyl alcohol, solid sodium chloride, solid sodium hydroxide, aqueous hydrochloric acid at 1 M and aqueous sodium hydroxide at 1 M. For these acid-base solutions, the selected 1 N products correspond to the nominal 1 M target. A supplier sheet covering a concentration range that included 1 M also qualified.
The sample was deliberately selected: six Fisher Chemical documents, six Flinn Scientific documents and one MilliporeSigma document. It cannot represent all chemicals, formulations or supplier practices in the U.S. market. Grades and concentrations are not assumed to match across suppliers.
The Flinn isopropanol SDS names the chemical but gives no assay, leaving its match to the purity target of at least 99% unconfirmed. Removing it leaves 12 documents, six explicit HCS 2024 references, two numerical dynamic-viscosity entries and no numerical kinematic-viscosity or particle-size entries. That calculation shows how this uncertainty affects the counts. It does not verify the other twelve grades or make the sample representative.
Each SDS is checked for seven fields: revision date, HCS-edition wording, evidence of substance or mixture status, physical state, particle information, viscosity information and a U.S. supplier contact. The 91 entries are 13 documents times seven fields. They are not 91 independent SDS. The contact field records a U.S. address and telephone contact as shown. It does not confirm whether the number works or whether the emergency instructions are adequate.
The sources are six Fisher Chemical SDS, six Flinn Scientific digital SDS and one MilliporeSigma acetone SDS. The workbook gives the supplier links and observations by section for all 13 documents.
Scope of the findings
The classifications depend on how each document's wording is interpreted. SDS using the same supplier template share features, and the HCS-edition wording varies with both supplier and revision period. This small, uneven sample cannot support estimates for the whole market or comparisons of supplier performance.
The checks do not assess toxicology, exposure limits, hazard or transport classification, or the adequacy of emergency instructions. Missing information in Sections 12 through 15 is not treated as an OSHA failure, because OSHA does not enforce the information requirements for those sections. Section 1910.1200(g)(2), Note 2.
Applying the findings to an SDS library
For a product in an employer's inventory, the first check is the product identity and supplier, followed by the concentration or grade covered by the sheet. A recent download date cannot resolve a mismatch. Revision dates, print dates and the date a supplier sent an updated sheet should be stored separately.
A property query to a supplier should identify the actual entry: for example, a dynamic-viscosity value in Section 9 when the requested property is kinematic viscosity, or a solid's appearance description without a separate particle entry. The request can then ask whether further applicable information is available. The audit does not supply replacement values for an employer to insert into a supplier's SDS.
Federal OSHA does not prescribe a universal annual or three-year SDS replacement interval. Under 29 CFR 1910.1200(g)(5), a preparer that becomes newly aware of significant hazard or protective information must add it within three months, subject to the rule's provision for a chemical not currently produced or imported. HCS transition duties must also be considered. OSHA update requirement.
Paragraph (g)(6) addresses manufacturers' and importers' supply of the SDS with an initial shipment and the first shipment after an update; paragraph (g)(7) addresses distributors. OSHA's enforcement directive explains the employer's duty to retain the most recent SDS received and addresses efforts to obtain missing sheets. A supplier's currently public webpage and an employer's actual shipment records are different evidence sources. This pilot examined the former. OSHA standard and HazCom enforcement directive. See also the guide to SDS revision and update duties.
Data and reuse
Related HazComFast work addresses different questions: acute-toxicity statements in SDS Sections 2, 3 and 11 and wording in Spanish-language SDS. Neither is a substitute for this pilot's date and physical-property observations.
HazComFast-authored text and observations are available under CC BY 4.0. Supplier SDS retain their owners' rights.
Suggested citation: HazComFast. HCS 2024 SDS pilot audit: 13 supplier documents. Document snapshot: November 18, 2026.
Federal OSHA penalty limits were last checked against the eCFR, OSHA.gov and the Federal Register on October 19, 2026, and HCS transition dates on June 23, 2026. Last reviewed November 23, 2026.
About This Article
Published by: HazComFast
Published: November 18, 2026
Last Updated: November 23, 2026
This content is for informational purposes only and does not constitute legal advice.