What 29 CFR 1926.100 requires (plain English)
29 CFR 1926.100 requires head protection for construction workers wherever there is a possible danger of head injury. Struck-by incidents, including being hit by falling or flying objects, are one of construction's "Focus Four" leading causes of death. The standard's trigger is broad: employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, must be protected by protective helmets.
Hard hats must meet the ANSI Z89.1 consensus standard, which classifies them two ways. By impact type: Type I protects against blows to the top of the head; Type II adds protection against lateral (side) impact. By electrical class: Class G (General) is tested to 2,200 volts, Class E (Electrical) to 20,000 volts, and Class C (Conductive) offers no electrical protection. The class must correspond to the actual hazard and to the marking. These are helmet test classes, not approach distances or permission to work at those voltages.
Head protection does not replace the protection of employees above and below the work, such as toeboards and screens on scaffolds and barricades below overhead work. 1926.100 sets no uniform expiry date for hard hats: the condition, any impact, the manufacturer's instructions and the recommended service life decide replacement, and 1926.95(a) has PPE maintained in a sanitary and reliable condition. 1926.95(c)(2) has the PPE selected to fit each affected employee. 1926.95(d) has the PPE provided at no cost to employees, with the exceptions of (d)(2) to (d)(6), among them replacement PPE the employee lost or intentionally damaged and adequate PPE the employee owns and chooses to use; the employer cannot require the employee to buy the required hard hat. OSHA's Safety Helmets bulletin describes Type II helmets with a chin strap as a choice based on the hazards, not as a new federal obligation of 1926.100.